该回顾性队列研究纳入2012至2024年行动脉调转术后的右型大动脉转位患者及心脏结构正常的对照,用4D血流MRI定量主动脉与肺动脉的速度、动能、能量损失及壁面剪切应力等指标。结果显示患者肺动脉上述多项血流动力学参数显著高于年龄匹配对照(P<0.0001),主动脉部分参数亦显著升高。

要点

  • 动脉调转术后右型大动脉转位患者肺动脉最大及平均速度、动能、能量损失和壁面剪切应力均显著高于对照(P<0.0001)。
  • 主动脉最大及平均速度、动能、能量损失及部分区域壁面剪切应力也显著高于年龄匹配对照。
  • 4D血流MRI可定量显示大动脉血流动力学异常,可能有助于理解动脉调转术后并发症机制。

核心结论

  • 行动脉调转术后的右型大动脉转位患者大动脉内存在血流动力学异常,可能为理解术后并发症机制提供线索。

研究设计与样本

  • IRB批准的回顾性队列研究,纳入2012至2024年行动脉调转术后的右型大动脉转位患者及心脏结构正常的对照,使用4D血流MRI定量主动脉与肺动脉血流动力学参数,采用非配对t检验或Mann-Whitney检验比较。

诊断标准与关键数值

  • 右型大动脉转位患者肺动脉最大及平均速度、最大及平均动能、能量损失、最大及平均壁面剪切应力均显著高于年龄匹配对照(P<0.0001)。
  • 右型大动脉转位患者主动脉最大速度(P=0.001)及平均速度(P=0.048)显著高于年龄匹配对照。
  • 右型大动脉转位患者主动脉最大动能(P=0.0008)及平均动能(P=0.003)显著高于年龄匹配对照。
  • 右型大动脉转位患者主动脉能量损失显著高于年龄匹配对照(P<0.0001)。
  • 右型大动脉转位患者主动脉六个区域中五个区域的最大壁面剪切应力(P范围<0.0001至0.002)及三个区域的平均壁面剪切应力(P范围0.005至0.03)显著高于年龄匹配对照。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Pulmonary artery stenosis, neoaortic dilatation, and neoaortic valve insufficiency are among the most frequent complications of the arterial switch operation for repair of dextro-transposition of the great arteries (d-TGA). It remains difficult to predict which patients will require great arterial reintervention.

OBJECTIVE: We aimed to characterize hemodynamics within the great arteries using 4D flow MRI in patients with d-TGA after the arterial switch operation.

MATERIALS AND METHODS: Patients with d-TGA after the arterial switch operation and controls with normal cardiac anatomy who underwent 4D flow MRI between 2012 and 2024 were included in this IRB-approved retrospective cohort study. Controls included patients undergoing MRI for other indications who consented or assented to the addition of a 4D flow sequence, as well as patients who underwent clinically indicated 4D flow MRI and were found to have normal cardiac anatomy and function. Velocity, stasis, kinetic energy, energy loss, wall shear stress, and pulse wave velocity were quantified in the aorta and pulmonary arteries. To compare each parameter between d-TGA patients and controls, unpaired t-tests were used for normally distributed data and Mann-Whitney tests for non-normal data. P < 0.05 was significant.

RESULTS: Patients with d-TGA after the arterial switch operation (15.7 years ± 2.4, 2 females) demonstrated significantly higher maximum and mean velocity, maximum and mean kinetic energy, energy loss, and maximum and mean wall shear stress within the pulmonary arteries (P < 0.0001 for all parameters) compared with age-matched controls (15.5 years ± 2.4, 14 females). Aortic maximum (P = 0.001) and mean (P = 0.048) velocity, maximum (P = 0.0008) and mean (P = 0.003) kinetic energy, energy loss (P < 0.0001), maximum wall shear stress in five of six regions (range P < 0.0001 to P = 0.002), and mean wall shear stress in three regions (range P = 0.005 to P = 0.03) were significantly higher in patients with d-TGA after the arterial switch operation patients compared with age-matched controls.

CONCLUSION: Patients with d-TGA after the arterial switch operation demonstrate hemodynamic abnormalities within the great arteries, which may provide insight into the mechanisms underlying postoperative consequences of the arterial switch operation.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Calderon K, Sodhi A, Johnson EMI, et al. Hemodynamic evaluation of the pulmonary arteries and aorta using 4D flow cardiac MRI in children and young adults with dextro-transposition of the great arteries after the arterial switch operation. Pediatr Radiol. 2024. PMID: 39704828. doi:10.1007/s00247-024-06110-4