文献速递心血管CT

动态负荷心肌CT灌注与有创造影生理学在支架患者中的诊断准确性比较:Advantage 2研究

Diagnostic Accuracy of Dynamic Stress Myocardial CT Perfusion Compared with Invasive Physiology in Patients with Stents: The Advantage 2 Study.
PubMed 文献 · Radiology · 2024-01-01

前瞻性纳入156例有支架、疑支架内再狭窄或病变进展需行有创造影的患者,比较动态负荷CTP与CCTA以FFR和IMR为参考标准的诊断效能。CTP的诊断率高于CCTA,以FFR和IMR为参考时CTP的敏感度、特异度和准确度均高于CCTA。

要点

  • 支架患者中动态负荷CTP的诊断率高于CCTA(98.7% vs 95.6%)。
  • 以FFR为参考,CTP敏感度、特异度、准确度均高于CCTA。
  • 以IMR为参考,CTP敏感度、特异度、准确度亦高于CCTA。

核心结论

  • 在冠状动脉支架患者中,动态CTP较CCTA提高了基于血管 territory 的缺血检测诊断效能。

研究设计与样本

  • 前瞻性研究,2021年1月至2022年6月连续纳入156例有支架且疑ISR或冠状动脉疾病进展需行有创造影的患者(136例男性,平均年龄63.1岁±8.2),共504枚支架;采用宽覆盖(z轴覆盖16 cm)、快速(机架旋转时间0.28秒)扫描仪行动态负荷心肌CTP和静息CTP加CCTA,以有创造影中获得的FFR和IMR为参考标准。

诊断标准与关键数值

  • 以FFR为参考标准,CTP敏感度89.0%、特异度82.8%、诊断准确度84.7%,CCTA分别为60.0%、61.9%、61.5%(P < .001);以IMR为参考标准,CTP敏感度76.5%、特异度85.9%、诊断准确度82.9%,CCTA分别为48.2%、63.5%、59.3%(P < .01);诊断率CTP 98.7%(789/799个territory)vs CCTA 95.6%(764/799个territory),P < .001。

临床应用与阅片要点

  • 在支架患者中,动态负荷CTP可较CCTA提高基于territory的缺血诊断率与诊断准确度;负荷CTP加CCTA的平均有效剂量为10.4 mSv±2.7。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background The detection of in-stent restenosis (ISR) with coronary CT angiography (CCTA) is challenging, but CT perfusion (CTP) has demonstrated improved diagnostic accuracy over CCTA in patients with stents. However, there are limited data on the performance of dynamic CTP, which allows noninvasive adjudication of regional myocardial blood flow. Purpose To compare the diagnostic performance of regadenoson-stress dynamic CTP with that of CCTA, using fractional flow reserve (FFR) and the index of microvascular resistance (IMR) as reference standards for epicardial coronary circulation and coronary microcirculation, respectively. Materials and Methods Between January 2021 and June 2022, this prospective study enrolled patients with stents with indication for invasive coronary angiography due to suspicion of ISR or coronary artery disease progression. Participants underwent dynamic stress myocardial CTP and rest CTP plus CCTA. A wide coverage (z-axis coverage, 16 cm) and fast (gantry rotation time, 0.28 second) scanner was used. During invasive coronary angiography, FFR and IMR were obtained. The diagnostic rate (number of interpretable territories divided by number of evaluated territories) and accuracy of CCTA and CTP were evaluated in a territory-based analysis and compared with FFR and IMR (primary end points of the study). Results The study included 156 consecutive patients (136 men [87%]; mean age, 63.1 years ± 8.2 [SD]) with 504 stents. The diagnostic rate was higher for CTP than for CCTA (98.7% [789 of 799 territories] vs 95.6% [764 of 799 territories], P < .001). With use of FFR as the reference standard, sensitivity, specificity, and diagnostic accuracy were higher for CTP than for CCTA (89.0%, 82.8%, and 84.7%, respectively, vs 60.0%, 61.9%, and 61.5%; P < .001). With use of IMR as the reference standard, sensitivity, specificity, and diagnostic accuracy were higher with CTP than with CCTA (76.5%, 85.9%, and 82.9%, respectively, vs 48.2%, 63.5%, and 59.3%; P < .01). The mean effective dose of stress CTP plus CCTA was 10.4 mSv ± 2.7. Conclusion In patients with coronary stents, dynamic CTP improves the diagnostic performance of CCTA in the detection of territory-based ischemia. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Williams in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Andreini D, Mushtaq S, Trabattoni D, et al. Diagnostic Accuracy of Dynamic Stress Myocardial CT Perfusion Compared with Invasive Physiology in Patients with Stents: The Advantage 2 Study. Radiology. 2024. PMID: 39688482. doi:10.1148/radiol.232225

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。