新型虚拟对比增强提升技术可降低腹主动脉CT血管成像的静脉对比剂剂量

New virtual contrast enhancement boost technique can reduce the dose of intravenous contrast medium used in computer tomography angiography of the abdominal aorta.
PubMed 文献 · Abdom Radiol (NY) · 2024-12-09

前瞻性研究纳入14例既往诊断为腹主动脉瘤的患者,每例先后接受两次主动脉CTA:一次采用虚拟对比增强提升技术并将静脉对比剂剂量降低40%,另一次按常规方案不降低对比剂剂量。定性分析显示两种方案图像质量均满足诊断目的,各动脉节段平均衰减在虚拟增强提升技术有升高趋势但无统计学显著差异,SNR与CNR相当。作者认为虚拟对比增强可在降低40%静脉对比剂剂量的同时保持可比图像质量。

要点

  • 虚拟对比增强提升技术将静脉碘对比剂剂量降低40%后,腹主动脉CTA图像质量仍满足诊断目的。
  • 两种方案各动脉节段平均衰减无统计学显著差异,虚拟增强提升技术呈升高趋势,SNR与CNR相当。
  • 几乎所有动脉节段在两种方案中均评为良好或优秀。

核心结论

  • 在主动脉CTA中应用虚拟对比增强提升技术可保持与常规方案相当的图像质量,同时将静脉对比剂剂量降低40%。
  • 该方法提示可在血管成像中优化对比剂使用,符合患者安全与放射效率的目标。

研究设计与样本

  • 前瞻性研究,纳入既往诊断为腹主动脉瘤的患者14例,共分析28次检查(每例两次)。
  • 每例先后接受两次主动脉CTA:一次采用虚拟对比增强提升技术并将静脉对比剂剂量降低40%,另一次采用常规方案且对比剂剂量不降低。
  • 虚拟增强提升技术的碘图通过数字减影技术叠加于对比增强图像获得。
  • 对主动脉及其分支血管的强化程度进行定性与定量评估。

关键影像表现/征象

  • 定性分析显示两种方案图像质量均满足诊断目的,几乎所有动脉节段均评为良好或优秀。
  • 各动脉节段平均衰减在虚拟对比增强提升技术较常规方案呈升高趋势,但无统计学显著差异。
  • 虚拟对比增强提升技术与常规方案的SNR和CNR水平相当。

临床应用与阅片要点

  • 作者认为该虚拟对比增强提升技术提示可在血管成像中优化对比剂使用,符合患者安全与放射效率的目标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This study aims to evaluate the image quality of computed tomography (CT) angiograms obtained using a virtual contrast augmentation technique, adding an iodine map to the contrast-enhanced images, obtained through a digital subtraction technique, reducing the dose of intravenous iodinated contrast medium compared to the conventional institutional standard technique.

METHODS: This prospective investigation enrolled patients previously diagnosed with abdominal aortic aneurysms, who underwent two successive computed tomography angiographies (CTAs) of the aorta. One CTA was performed employing the virtual contrast enhancement boost technique with a 40% decrease in the intravenous contrast medium dose, while the other adhered to the conventional protocol without any reduction in contrast medium volume. After imaging, both qualitative and quantitative assessments were conducted to evaluate the opacification level of the aorta and its branching vessels.

RESULTS: The study analyzed 28 examinations from 14 subjects (two per participant). Qualitative analysis revealed that image quality was deemed adequate for diagnostic purposes, with nearly all arterial segments in both protocols rated as good or excellent. Although no statistically significant differences were detected, the average attenuation across all arterial segments in the angiograms exhibited a trend towards higher values in the virtual contrast enhancement boost technique, compared to the conventional protocol. Similarly, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) demonstrated comparable levels between the two methodologies.

CONCLUSION: The application of virtual contrast enhancement in the acquisition of CT angiograms of the aorta maintains comparable image quality, while reducing the dosage of intravenous contrast medium by 40%. This approach suggests a potential for optimizing contrast use in vascular imaging, aligning with goals related to patient safety and radiological efficiency.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。