四维血流MRI评估妊娠晚期胎儿心血管血流动力学的可靠性

Reliability of 4D Flow MRI for Investigation of Fetal Cardiovascular Hemodynamics in the Third Trimester.
PubMed 文献 · Radiol Cardiothorac Imaging · 2024-01-01

前瞻性纳入34例孕妇(22例健康胎儿、12例超声怀疑主动脉缩窄胎儿),在3 T下行多普勒超声门控胎儿四维血流MRI,评估测量精度、质量守恒内部一致性、与二维相位对比MRI的一致性及重复采集可重复性。四维血流测量可靠,但绝对血流量较二维相位对比MRI低估约34%。

要点

  • 胎儿四维血流MRI在3 T下可行,相邻测量平面精度高,受试者内变异系数平均7%。
  • 四维血流与二维相位对比MRI净流量相关(r=0.51),但绝对值低估约34%。
  • 重复采集间一致性良好,组内相关系数0.94。

核心结论

  • 胎儿四维血流MRI血流动力学测量可靠,内部一致性、精度和可重复性良好,但绝对值血流量较二维相位对比MRI低估。

研究设计与样本

  • 前瞻性研究,2021年5月至2023年10月招募孕妇34例(平均年龄33岁±5,平均孕龄35周±2;健康胎儿22例,超声怀疑主动脉缩窄胎儿12例),3 T下行多普勒超声门控胎儿四维血流MRI,并采集重复四维血流及二维相位对比MRI数据。

诊断标准与关键数值

  • 所有血管节段精度高,受试者内变异系数平均7%;质量守恒方面,动脉导管加峡部流量与降主动脉流量平均差异19%±12(r=0.76);四维血流与二维相位对比MRI净流量相关(r=0.51),但四维血流较二维相位对比MRI低估约34%;重复四维血流采集间组内相关系数0.94。

临床应用与阅片要点

  • 胎儿四维血流MRI可用于评估妊娠晚期胎儿血流动力学,测量精度和可重复性良好,但绝对血流量较二维相位对比MRI低估约34%,解读绝对流量值时需注意此系统偏差。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To provide reference values for four-dimensional (4D) flow MRI in healthy fetuses and evaluate reliability of fetal 4D flow MRI hemodynamics in third trimester fetuses with normal cardiovascular development or suspected coarctation of the aorta (CoA). Materials and Methods Pregnant patients with healthy fetuses or fetuses with echocardiographic concern for CoA were prospectively recruited between May 2021 and October 2023. Doppler US-gated fetal 4D flow MRI was performed at 3 T. Repeated 4D flow (time permitting) and two-dimensional (2D) phase contrast (PC) MRI data were acquired. Net flow was quantified, and the reliability of 4D flow measurement was evaluated by using precision across adjacent measurement planes, internal consistency based on conservation of mass, comparison of net flow from 4D flow MRI versus 2D PC MRI, and repeatability of 4D flow from separate acquisitions. Results Data were obtained in 34 pregnant participants (mean maternal age, 33 years ± 5 [SD]; mean gestational age, 35 weeks ± 2; n = 22 healthy fetuses and 12 fetuses with suspected CoA). Precision was high across all vascular segments (mean within-subject coefficient of variation = 7%). For mass conservation, there was an average difference of 19% ± 12 between ductus arteriosus plus isthmus flow versus descending aorta flow (r = 0.76). Net flow measured with 4D flow MRI correlated with that measured with 2D PC MRI (r = 0.51) but was underestimated relative to 2D PC MRI by approximately 34%. Hemodynamic parameters quantified from repeated 4D flow acquisitions had good agreement, with an intraclass correlation coefficient of 0.94 between test and retest data. Conclusion Hemodynamic measurements derived from fetal 4D flow MRI were reliable, showing good internal consistency, precision, and repeatability; however, as expected, 4D flow MRI underestimated absolute blood flow relative to 2D PC MRI. Keywords: Fetal MRI, Cardiac, Aorta, Hemodynamics/Flow Dynamics, Pulmonary Arteries Supplemental material is available for this article. © RSNA, 2024.