文献速递心血管MR

快速自由呼吸心脏定量磁敏感成像准确评估心肌内出血

Accurate Intramyocardial Hemorrhage Assessment with Fast, Free-running, Cardiac Quantitative Susceptibility Mapping.
PubMed 文献 · Radiol Cardiothorac Imaging · 2024-01-01

本研究在铁校准体模和14只雌性犬心肌内出血模型中,评估高动态范围定量磁敏感成像(HDR-QSM)检测心肌内出血和量化铁含量的性能,并与R2* mapping比较,以离体成像为参考标准;结果显示HDR-QSM在图像质量、出血检测和铁定量方面均优于R2*,可在5分钟内无需屏气完成全心脏扫描。

要点

  • HDR-QSM可在5分钟内无需屏气完成全心脏扫描,显著减轻运动与偏共振伪影。
  • 在犬模型中,HDR-QSM检测心肌内出血的AUC为0.96,优于R2*的0.75。
  • HDR-QSM铁定量与离体测量的R²为0.71,优于R2*的0.14。

核心结论

  • 在犬心肌内出血模型中,快速自由呼吸心脏QSM技术可在5分钟内无需屏气准确检测心肌内出血并量化全心脏心肌铁含量。

研究设计与样本

  • 研究论文;在铁校准体模和14只雌性犬心肌内出血模型中评估HDR-QSM,并与传统R2*(1/T2*)图比较,以离体成像测量为参考标准。

关键影像表现/征象

  • 体模研究显示铁浓度与QSM值呈强线性关系(R²=0.98),证实HDR-QSM可准确量化铁含量并减轻伪影。
  • 在体研究中,HDR-QSM减轻运动与偏共振伪影,非受累心肌的信号均匀性优于R2*(变异系数0.31±0.16 vs 0.73±0.36,P<.001)。
  • HDR-QSM图像质量评分高于R2*(五点Likert量表3.58±0.75 vs 2.87±0.51,P<.001)。

诊断标准与关键数值

  • 以离体成像为参考标准,HDR-QSM检测心肌内出血的AUC为0.96,R2*为0.75(P<.001)。
  • HDR-QSM铁含量定量与离体测量的R²为0.71,R2*为0.14。

临床应用与阅片要点

  • HDR-QSM可在5分钟内无需屏气完成全心脏扫描,图像质量与信号均匀性优于R2*。
  • 在犬模型中,HDR-QSM检测心肌内出血和量化铁含量的性能高于R2*。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To evaluate the performance of a high-dynamic-range quantitative susceptibility mapping (HDR-QSM) cardiac MRI technique to detect intramyocardial hemorrhage (IMH) and quantify iron content using phantom and canine models. Materials and Methods A free-running whole-heart HDR-QSM technique for IMH assessment was developed and evaluated in calibrated iron phantoms and 14 IMH female canine models. IMH detection and iron content quantification performance of this technique was compared with the conventional iron imaging approaches, R2*(1/T2*) maps, using measurements from ex vivo imaging as the reference standard. Results Phantom studies confirmed HDR-QSM's accurate iron content quantification and artifact mitigation ability by revealing a strong linear relationship between iron concentration and QSM values (R2, 0.98). In in vivo studies, HDR-QSM showed significantly improved image quality and susceptibility homogeneity in nonaffected myocardium by alleviating motion and off-resonance artifacts (HDR-QSM vs R2*: coefficient of variation, 0.31 ± 0.16 [SD] vs 0.73 ± 0.36 [P < .001]; image quality score [five-point Likert scale:], 3.58 ± 0.75 vs 2.87 ± 0.51 [P < .001]). Comparison between in vivo susceptibility maps and ex vivo measurements showed higher performance of HDR-QSM compared with R2* mapping for IMH detection (area under the receiver operating characteristic curve, 0.96 vs 0.75; P < .001) and iron content quantification (R2, 0.71 vs 0.14). Conclusion In a canine model of IMH, the fast and free-running cardiac QSM technique accurately detected IMH and quantified intramyocardial iron content of the entire heart within 5 minutes without requiring breath holding. Keywords: High-Dynamic-Range Quantitative Susceptibility Mapping, Myocardial Infarction, Intramyocardial Hemorrhage, MRI Supplemental material is available for this article. ©RSNA, 2024.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Huang Y, Guan X, Zhang X, et al. Accurate Intramyocardial Hemorrhage Assessment with Fast, Free-running, Cardiac Quantitative Susceptibility Mapping. Radiol Cardiothorac Imaging. 2024. PMID: 39665631. doi:10.1148/ryct.230376

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。