文献速递胸部技术与安全MRCT

利用三维各向同性超短回波时间肺部MRI的相位信息检测胸部淋巴结肿大:迈向一站式扫描方案

Leveraging Phase Information of 3D Isotropic Ultrashort Echo Time Pulmonary MRI for the Detection of Thoracic Lymphadenopathy: Toward an All-in-One Scan Solution.
PubMed 文献 · Invest Radiol · 2024-11-19

前瞻性研究纳入42例患者共136枚淋巴结,在14天内行静脉CT和FLORET 3D各向同性UTE肺部MRI,由三名放射科医生盲法阅读,以CT为参考计算UTE相位图像对淋巴结的检出率与诊断效能。相位图像对纵隔和肺门病理性淋巴结(短轴直径≥10 mm)平均敏感度95.83%、特异度100%,纳入所有淋巴结区域和大小后平均敏感度77.9%、特异度99.4%,读者间一致性κ=0.92。作者认为相位图像凭借水脂对比和高空间分辨率可高置信度检出纵隔和肺门病理性淋巴结,将UTE的应用扩展至肺实质与淋巴结的同时评估。

要点

  • UTE相位图像对纵隔和肺门病理性淋巴结(SAD≥10 mm)平均敏感度95.83%、特异度100%。
  • 纳入所有淋巴结区域和大小后平均敏感度降至77.9%、特异度99.4%。
  • 三名读者间一致性几乎完美,Fleiss κ=0.92。

核心结论

  • 纵隔和肺门病理性淋巴结可在相位图像上以高诊断置信度检出,归因于相位图像呈现水脂对比并结合高空间三维分辨率,将UTE的临床应用扩展至肺实质与淋巴结的同时评估。

研究设计与样本

  • 前瞻性研究,42例患者共136枚淋巴结,在14天间隔内行静脉CT和肺部MRI扫描,3D各向同性UTE图像采用FLORET(fermat环状正交编码轨迹)采集,背景校正相位图像(UTE-P)与幅度图像自UTE信号同时重建,三名放射科医生盲法阅读检出所有短轴直径至少0.5 cm的淋巴结,以CT为参考计算检出率和效能指标,读者间一致性采用Fleiss κ计算。

诊断标准与关键数值

  • 以CT为参考,相位图像对纵隔和肺门病理性淋巴结(SAD≥10 mm)平均敏感度95.83%(CI 92.76%-98.91%)、特异度100%、阳性预测值100%、阴性预测值99.32%(CI 98.08%-100%)。

临床应用与阅片要点

  • 作者认为相位图像可高诊断置信度检出纵隔和肺门病理性淋巴结,并将UTE应用扩展至肺实质与淋巴结的同时评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Ultrashort echo time (UTE) allows imaging of tissues with short relaxation times, but it comes with the expense of long scan times. Magnitude images of UTE magnetic resonance imaging (MRI) are widely used in pulmonary imaging due to excellent parenchymal signal, but have insufficient contrast for other anatomical regions of the thorax. Our work investigates the value of UTE phase images (UTE-Ps)-generated simultaneously from the acquired UTE signal used for the magnitude images-for the detection of thoracic lymph nodes based on water-fat contrast. It employs an advanced imaging sequence and reconstruction allowing isotropic 3D UTE MRI in clinically acceptable scan times.

METHODS: In our prospective study, 42 patients with 136 lymph nodes had undergone venous computed tomography and pulmonary MRI scans with UTE within a 14-day interval. 3D isotropic UTE images were acquired using FLORET (fermat looped, orthogonally encoded trajectories). Background-corrected phase images (UTE-P) and magnitude images were reconstructed simultaneously from the UTE-Signal. Three radiologists performed a blinded reading in which all lymph nodes with a short-axis diameter (SAD) of at least 0.5 cm were detected. Detection rates and performance metrics of UTE-P for all lymph node regions and for pathologic (SAD ≥10 mm) and nonpathologic lymph nodes (SAD <10 mm) were calculated using computed tomography as a reference. The interreader agreement defined as the presence or absence of lymph nodes based on patient and region was calculated using Fleiss kappa (κ).

FINDINGS: In the phase images, pathologic lymph nodes in the mediastinal and hilar region were detected with a high diagnostic confidence due to the achieved water-fat contrast (average sensitivity, specificity, positive predictive value, and negative predictive value of 95.83% [confidence interval (CI), 92.76%-98.91%], 100%, 100%, and 99.32% [CI, 98.08%-100%]). Stepwise inclusion of all lymph node regions and nonpathologic lymph nodes was associated with a moderate decrease resulting in an average sensitivity, specificity, positive predictive value, and negative predictive value of 77.9% (CI, 70.9%-84.7%), 99.4% (CI, 98.7%-99.9%), 97.0% (CI, 93.4%-99.7%), and 94.7% (CI, 92.8%-96.4%) for the inclusion of all lymph nodes sizes and regions. Interreader agreement was almost perfect (κ = 0.92).

CONCLUSIONS: Pathological lymph nodes in the mediastinal and hilar region can be detected in phase-images with high diagnostic confidence, thanks to the ability of the phase images to depict water-fat contrast in combination with high spatial 3D resolution, extending the clinical applicability of UTE into the simultaneous assessment of lung parenchyma and lymph nodes.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Ziegelmayer S, Van AT, Weiss K, et al. Leveraging Phase Information of 3D Isotropic Ultrashort Echo Time Pulmonary MRI for the Detection of Thoracic Lymphadenopathy: Toward an All-in-One Scan Solution. Invest Radiol. 2024. PMID: 39680826. doi:10.1097/RLI.0000000000001135

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。