深度学习重建用于乳腺癌常规与合成扩散加权成像的临床可行性:定性与定量分析
本研究回顾性分析115例经活检证实的乳腺恶性肿瘤患者,比较深度学习重建的cDWI800、sDWI1500与常规cDWI800、sDWI1500。DL-DWI800和sDL-DWI1500在病灶显示及胸肌、肋骨勾勒上优于常规图像(均P<0.05),正常实质信号及SNR、CNR无显著差异,且采集时间更短。
要点
- DL-DWI800与sDL-DWI1500病灶显示及胸肌、肋骨勾勒优于常规cDWI800与sDWI1500(均P<0.05)。
- sDL-DWI1500与sDWI1500的SNR、CNR无显著差异(P=0.908、P=0.081)。
- DL-DWI800与cDWI800的SNR、CNR、CPR均无显著差异(均P>0.05)。
核心结论
- DL-DWI在高b值下定性与定量分析均优于cDWI和sDWI,同时采集时间更短。
研究设计与样本
- 回顾性分析2022年7月至2023年6月经活检证实的115例乳腺恶性肿瘤患者,行乳腺MRI,包括cDWI800、sDWI1500、DL-DWI800和sDL-DWI1500;两名放射科医师独立用5点Likert量表定性分析,并定量分析SNR、CNR和CPR。
关键影像表现/征象
- DL-DWI800和sDL-DWI1500的病灶显示及胸肌、肋骨勾勒优于cDWI800和sDWI1500(均P<0.05)。
- DL-DWI800和sDL-DWI1500的正常实质信号与cDWI800和sDWI1500相当(均P>0.05)。
诊断标准与关键数值
- 定性分析采用5点Likert量表。
- sDL-DWI1500与sDWI1500的SNR和CNR无显著差异(P=0.908和P=0.081)。
- DL-DWI800与cDWI800的SNR、CNR和CPR均无显著差异(均P>0.05)。
临床应用与阅片要点
- DL-DWI800和sDL-DWI1500在保持正常实质信号与常规图像相当的同时,可能提供更好的病灶显示及胸肌、肋骨勾勒。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: In this study, we aimed to investigate the clinical feasibility of deep learning (DL)-based reconstruction applied to conventional diffusion-weighted imaging (cDWI) and synthetic diffusion-weighted imaging (sDWI) by comparing the DL reconstructions to cDWIs and sDWIs in patients with various breast malignancies.
METHODS: We retrospectively analyzed 115 patients with biopsy-proven breast malignancies who underwent breast magnetic resonance imaging from July 2022 to June 2023, including cDWI with b-value of 800 s/mm2 (cDWI800), sDWI with b-value of 1500 s/mm2 (sDWI1500), DWI using DL-based reconstruction (DL-DWI) with b-value of 800 s/mm2, and synthetic DL-DWI with b-value of 1500 s/mm2 (DL-DWI800 and sDL-DWI1500). Two radiologists independently performed the qualitative analyses using a 5-point Likert scale for all DWI sets. The quantitative analyses were also conducted for signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and cancer-to-parenchyma contrast ratio (CPR).
RESULTS: DL-DWI800 and sDL-DWI1500 provided better lesion conspicuity and thoracic muscle and rib delineation than cDWI800 and sDWI1500 (all P < 0.05). DL-DWI800 and sDL-DWI1500 showed comparable normal parenchymal signals to those of cDWI800 and sDWI1500 (all P > 0.05). sDL-DWI1500 and sDWI1500 showed no significant differences in SNR and CNR (P = 0.908, and P = 0.081, respectively). DL-DWI800 and cDWI800 were not significantly different between SNR, CNR, and CPR (all P > 0.05).
CONCLUSIONS: DL-DWI outperformed cDWI and sDWI in both qualitative and quantitative analyses at the high b-values, while also achieving a shorter acquisition time.
引用
- Cho E, Baek HJ, Jung EJ, et al. Clinical feasibility of a deep learning approach for conventional and synthetic diffusion-weighted imaging in breast cancer: Qualitative and quantitative analyses. Eur J Radiol. 2024. PMID: 39616946. doi:10.1016/j.ejrad.2024.111855
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。