文献速递神经儿科影像MR

单次1分钟脑MRI扫描从定量弛豫图生成多种合成图像对比用于清醒儿童

A single 1-min brain MRI scan for generating multiple synthetic image contrasts in awake children from quantitative relaxometry maps.
PubMed 文献 · Pediatr Radiol · 2024-12-18

这项前瞻性研究纳入24名3-10岁清醒儿童,评估基于回波平面成像的多反转自旋与梯度回波(MI-SAGE)技术在54秒内生成定量脑图和合成对比图像的能力;MI-SAGE的T1、T2、T2*图与传统方法相关性中至极强,合成图像对比与传统图像相似,但伪影更多、Likert评分更低,扫描时间缩短十倍。

要点

  • MI-SAGE可在54秒内生成T1、T2、T2*定量图及合成加权图像。
  • 合成图像对比与传统加权图像相似,但磁敏感伪影更多、主观评分更低。
  • 该技术有望减少清醒儿童脑MRI的镇静需求。

核心结论

  • MI-SAGE衍生的T1、T2、T2*图与传统定量方法相关,具有强至极强的重复性和再现性;合成加权图像对比与传统图像相似,但磁敏感伪影更多、Likert评分更低,扫描时间缩短十倍。

研究设计与样本

  • 前瞻性IRB批准研究,纳入24名3-10岁清醒健康参与者(平均6.5±1.9岁,12名男性)。
  • 使用MI-SAGE、MOLLI、GRASE、mGRE及T1、T2、T2*、FLAIR加权序列扫描,MI-SAGE采集时间54秒。
  • 由神经放射学家对合成图像和传统加权图像进行5点Likert评分,比较灰白质对比比(GWR),采用Bland-Altman分析和组内相关系数(ICC)分析。

关键影像表现/征象

  • MI-SAGE合成T1w、T2w、T2*w、FLAIR的GWR与传统序列GWR的偏差分别为17%、3%、7%、1%。
  • 合成图像磁敏感伪影多于传统图像。

诊断标准与关键数值

  • MI-SAGE T1、T2、T2*与传统定量方法(分别为MOLLI、GRASE、mGRE)的偏差分别为32%、-4%、23%,ICC=0.49-0.99。
  • MI-SAGE各图的重复性和再现性ICC=0.80-0.99。
  • 合成T1w、T2w、T2*w、FLAIR的平均Likert评分分别为2.1、2.1、2.9、2.0,传统采集分别为3.5、3.6、4.6、3.8。

临床应用与阅片要点

  • MI-SAGE可在54秒内生成多种合成对比图像,有望用于清醒儿童脑MRI以减少镇静需求。
  • 合成图像磁敏感伪影较多且主观评分较低,阅片时需注意评估图像质量。

局限性

  • 合成MI-SAGE图像比传统图像有更多磁敏感伪影且Likert评分更低。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Diagnostically adequate contrast and spatial resolution in brain MRI require prolonged scan times, leading to motion artifacts and image degradation in awake children. Rapid multi-parametric techniques can produce diagnostic images in awake children, which could help to avoid the need for sedation.

OBJECTIVE: To evaluate the utility of a rapid echo-planar imaging (EPI)-based multi-inversion spin and gradient echo (MI-SAGE) technique for generating multi-parametric quantitative brain maps and synthetic contrast images in awake pediatric participants.

MATERIALS AND METHODS: In this prospective IRB-approved study, awake research participants 3-10 years old were scanned using MI-SAGE, MOLLI, GRASE, mGRE, and T1-, T2-, T2*-, and FLAIR-weighted sequences. The MI-SAGE T1, T2, and T2* maps and synthetic images were estimated offline. The MI-SAGE parametric values were compared to those from conventional mapping sequences including MOLLI, GRASE, and mGRE, with assessments of repeatability and reproducibility. Synthetic MI-SAGE images and conventional weighted images were reviewed by a neuroradiologist and scored using a 5-point Likert scale. Gray-to-white matter contrast ratios (GWRs) were compared between MI-SAGE synthetic and conventional weighted images. The results were analyzed using the Bland-Altman analysis and intra-class correlation coefficient (ICC).

RESULTS: A total of 24 healthy participants aged 3 years to 10 years (mean ± SD, 6.5 ± 1.9; 12 males) completed full imaging exams including the 54-s MI-SAGE acquisition and were included in the analysis. The MI-SAGE T1, T2, and T2* had biases of 32%, -4%, and 23% compared to conventional mapping methods using MOLLI, GRASE, and mGRE, respectively, with moderate to very strong correlations (ICC=0.49-0.99). All MI-SAGE maps exhibited strong to very strong repeatability and reproducibility (ICC=0.80 to 0.99). The synthetic MI-SAGE had average Likert scores of 2.1, 2.1, 2.9, and 2.0 for T1-, T2-, T2*-, and FLAIR-weighted images, respectively, while conventional acquisitions had Likert scores of 3.5, 3.6, 4.6, and 3.8 for T1-, T2-, T2*-, and FLAIR-weighted images, respectively. The MI-SAGE synthetic T1w, T2w, T2*w, and FLAIR GWRs had biases of 17%, 3%, 7%, and 1% compared to the GWR of images from conventional T1w, T2w, T2*w, and FLAIR acquisitions respectively.

CONCLUSION: The derived T1, T2, and T2* maps were correlated with conventional mapping methods and showed strong repeatability and reproducibility. While synthetic MI-SAGE images had greater susceptibility artifacts and lower Likert scores than conventional images, the MI-SAGE technique produced synthetic weighted images with contrasts similar to conventional weighted images and achieved a ten-fold reduction in scan time.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Ramaniharan AK, Pednekar A, Parikh NA, et al. A single 1-min brain MRI scan for generating multiple synthetic image contrasts in awake children from quantitative relaxometry maps. Pediatr Radiol. 2024. PMID: 39692886. doi:10.1007/s00247-024-06113-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。