基于限制回波间隔的类CT骨成像(FRACTURE)MR与CT在儿童先天性椎体异常中的比较
前瞻性纳入11例先天性椎体异常患儿,在同一镇静条件下行FRACTURE MR与CT检查,比较图像质量及椎体形成/分节异常、形态异常和排列畸形的评估。FRACTURE MR图像质量可接受,仅1例存在限制诊断的伪影;对分节或形成异常及排列异常的读者间一致性为完美,对后部结构异常为相当一致;3岁以下儿童因骨骼更不成熟且多软骨,骨信号较低。作者认为FRACTURE MR可补充常规MR提供骨性细节,CT可保留用于术后等特定指征,有助于减少此类需系列随访患儿的辐射剂量。
要点
- FRACTURE MR在儿童先天性椎体异常中图像质量可接受,仅1例存在限制诊断的伪影。
- 椎体分节或形成异常及排列异常的读者间一致性为完美,后部结构异常为相当一致。
- 3岁以下儿童因骨骼更不成熟且多软骨,FRACTURE MR骨信号较低。
核心结论
- FRACTURE MR在儿童脊柱异常中提供质量可接受的图像,可补充常规MR提供骨性细节。
- 作者认为CT可保留用于术后等特定指征,有助于减少此类需系列影像随访患儿的辐射剂量。
研究设计与样本
- 前瞻性纳入11例因先天性椎体异常转诊至影像科行CT和MR检查的患儿,经监护人知情同意后在同一环境、同一镇静下完成两项检查。
- FRACTURE MR采用压缩敏感度编码(CS)技术加速以缩短成像时间。
- 比较FRACTURE MR与CT的图像质量,并评估椎体形成或分节异常、椎体形态异常及排列畸形等参数。
关键影像表现/征象
- FRACTURE MR图像质量可接受,仅1例患者存在限制诊断的伪影。
- 3岁以下儿童因骨骼更不成熟且多软骨,骨信号较低。
诊断标准与关键数值
- 椎体分节或形成异常及排列异常的读者间一致性为完美。
- 后部结构异常的读者间一致性为相当一致。
临床应用与阅片要点
- FRACTURE MR可作为常规MR的补充序列,用于提供儿童先天性椎体异常的骨性细节。
- 作者认为CT可保留用于术后病例等特定指征。
- 3岁以下儿童因骨信号较低,阅片时需考虑年龄对FRACTURE MR骨信号的影响。
局限性
- 3岁以下儿童因骨骼更不成熟且多软骨,FRACTURE MR骨信号较低。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Congenital vertebral anomalies are commonly associated with underlying spinal cord anomaly that necessitates imaging both the spinal cord and the bony vertebral column to understand the extent of the deformity better. While MRI is the standard for spinal cord imaging, it does not provide CT-like bone details. Many MR bone imaging techniques have been tested in various adult spine conditions in the past decade but not much has been described on their reliability in pediatric spine. We elaborate on our experience with fast field echo resembling a CT by using restricted echo spacing (FRACTURE) MR bone imaging in congenital vertebral anomalies in children.
MATERIALS AND METHODS: Eleven pediatric patients referred to the imaging department for CT and MR study of congenital vertebral anomaly were prospectively included. After receiving informed consent from these patients' guardians, both studies were performed in a single setting and under a single sedation. FRACTURE MR was accelerated by using the compressed sensitivity encoding (CS) technique to reduce the imaging time. We then compared FRACTURE MR and CT images for image quality and studied parameters such as formation or segmentation anomalies, anomalous shape of vertebrae, and alignment deformities.
RESULTS: FRACTURE MR showed acceptable image quality with diagnostically limiting artifacts in only 1 patient. The interreader agreement was perfect in the assessment of vertebral body segmentation or formation anomaly and alignment abnormalities, and it was substantial for posterior element anomalies. The bone signal was lower in children under the age of 3 years due to a more immature and cartilaginous skeleton.
CONCLUSIONS: FRACTURE MR provides images of acceptable quality in pediatric spinal anomalies. The addition of this novel sequence can be complementary to conventional MR in providing osseous details and CT can be reserved for certain specific indications like postoperative cases. This can help in reducing the radiation dose to this group of pediatric patients who will be serially followed up with imaging during their management.
引用
- Manek H, Gala F. Comparing CT-Like Bone Images Based on Fast Field Echo Resembling a CT Using Restricted Echo Spacing (FRACTURE) MR with CT in Pediatric Congenital Vertebral Anomalies. AJNR Am J Neuroradiol. 2025. PMID: 39730157. doi:10.3174/ajnr.A8639
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。