轴位T2加权MRI序列在排除非定位症状儿童脑肿瘤中的诊断效能

Diagnostic performance of axial T2-weighted MRI sequence for exclusion of brain tumour in paediatric patients with non-localizing symptoms.
PubMed 文献 · Br J Radiol · 2024-12-02

回顾性分析312例因疑似脑肿瘤伴非定位症状接受脑MRI的儿童,由2名儿科神经放射学专家盲法评估轴位T2加权图像,并与标准MRI方案对比。轴位T2加权图像检测脑肿瘤的敏感度为1.000(95%CI 0.598, 1.000),特异度为0.998(95%CI 0.990, 0.999);仅基于T2加权图像有50例(16%)被标记需召回进一步成像,标准方案后召回14例(4.5%)。结论认为轴位T2加权图像敏感度和特异度高,但与成像召回率增加相关,需前瞻性评估。

要点

  • 轴位T2加权序列检测非定位症状儿童脑肿瘤的敏感度为1.000(95%CI 0.598, 1.000),特异度为0.998(95%CI 0.990, 0.999)。
  • 仅基于T2加权图像,50例(16%)被标记需召回进一步成像,标准方案后召回14例(4.5%)。
  • 作者认为,若已获得轴位T2加权序列,无法完成全MRI方案的患儿漏诊脑肿瘤的可能性很低。

核心结论

  • 轴位T2加权图像对非定位症状儿童脑肿瘤检测具有高敏感度和特异度,但与成像召回率增加相关;作者认为需前瞻性评估该方法来识别需要更全面成像的患者。

研究设计与样本

  • 回顾性分析3年期间因疑似脑肿瘤伴非定位症状接受脑MRI的儿童312例,轴位T2加权图像由2名经验丰富的儿科神经放射学专家盲法评估,以标准MRI方案为参考计算诊断效能。

诊断标准与关键数值

  • 轴位T2加权图像检测脑肿瘤的敏感度为1.000(95%CI 0.598, 1.000),特异度为0.998(95%CI 0.990, 0.999)。

临床应用与阅片要点

  • 作者认为,对于因非定位症状就诊的儿童,若已获得轴位T2加权序列,未能完成全MRI扫描方案者漏诊脑肿瘤的可能性很低;仅基于T2加权图像时50例(16%)被标记需召回进一步成像,标准方案后召回14例(4.5%)。

局限性

  • 原文结论指出,需前瞻性评估该方法来识别需要更全面成像的患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To establish diagnostic performance of a single axial T2-weighted sequence for detection of brain tumours in children with non-localizing symptoms, compared to a standard MRI protocol.

METHODS: Retrospective analysis of children undergoing MRI brain imaging for suspected brain tumours with non-localizing symptoms over a 3-year period. Axial T2-weighted images were blindly reviewed by 2 experienced paediatric neuroradiologists. Primary analysis was calculation of diagnostic performance metrics for tumour identification using axial T2-weighted image only compared to the standard MRI protocol.

RESULTS: For 312 children undergoing MRI brain during the study period, sensitivity and specificity for brain tumour detection based on axial T2-weighted images in children with non-localizing symptoms were 1.000 (95% CIs 0.598, 1.000) and 0.998 (95% CI 0.990, 0.999), respectively. Based on T2-weighted images alone, 50 patients (16%) were flagged as needing recall for further imaging compared to 14 (4.5%) recalled after the standard protocol.

CONCLUSIONS: Axial T2-weighted images have high sensitivity and specificity for detection of brain tumours in children with non-localizing symptoms but are associated with increased imaging recall rates. Prospective evaluation of this approach to identify patients requiring more comprehensive imaging is warranted.

ADVANCES IN KNOWLEDGE: A truncated MRI protocol with single axial T2-weighted sequence has high diagnostic performance for brain tumour detection in children with non-localizing features. Radiologists can be reassured that a child with this presentation who is unable to complete the full MRI scan protocol is very unlikely to have a brain tumour missed provided an axial T2-weighted sequence is obtained.