文献速递骨肌技术与安全CT

机会性CT骨质疏松筛查中感兴趣区选择对短期体内精密度的影响

Regions of interest in opportunistic computed tomography-based screening for osteoporosis: impact on short-term in vivo precision.
PubMed 文献 · Skeletal Radiol · 2024-11-18

本研究纳入2022年一个月内接受两次CT和一次双能X线吸收测定的73例连续患者,用深度学习软件在L1椎体以54种感兴趣区(ROI)方案自动测量衰减值。结果显示,1 mm或3 mm层厚图像上于L1椎体中部放置尽可能大的椭圆形ROI,短期体内精密度更优,RMSSD为12.4–12.5 HU,AUROC为0.90。

要点

  • 薄层(1 mm或3 mm)图像上ROI的两次CT衰减差值小于5 mm层厚图像(p < .001)。
  • 大椭圆形ROI、L1中部或头侧层面ROI的衰减差值更小(p < .001)。
  • L1中部大椭圆形ROI在1 mm或3 mm层厚图像上RMSSD为12.4–12.5 HU、AUROC为0.90。

核心结论

  • 在L1椎体中部骨小梁区域于薄层图像上绘制尽可能大的ROI,可能提高CT机会性骨质疏松筛查的精密度。

研究设计与样本

  • 回顾性纳入2022年一个月内接受两次CT和一次双能X线吸收测定的73例连续患者(平均年龄69±9岁,38例女性),用深度学习软件在L1椎体以3种层厚×6种形状×3个椎体层面共54种ROI方案自动测量衰减值,并以混合效应模型分析ROI层面和患者层面因素。

诊断标准与关键数值

  • 1 mm或3 mm层厚图像ROI的两次CT衰减差值小于5 mm层厚图像(p < .001);大椭圆形ROI的衰减差值更小(p = .007或< .001);L1中部或头侧层面ROI的衰减差值小于尾侧层面(p < .001);L1中部大椭圆形ROI在1 mm或3 mm层厚图像上RMSSD为12.4–12.5 HU,AUROC为0.90。

临床应用与阅片要点

  • 作者结论认为,在L1椎体中部骨小梁区域于薄层图像上绘制尽可能大的ROI,可能提高CT机会性骨质疏松筛查的精密度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine an optimal region of interest (ROI) for opportunistic screening of osteoporosis in terms of short-term in vivo diagnostic precision.

MATERIALS AND METHODS: We included patients who underwent two CT scans and one dual-energy X-ray absorptiometry scan within a month in 2022. Deep-learning software automatically measured the attenuation in L1 using 54 ROIs (three slice thicknesses × six shapes × three intravertebral levels). To identify factors associated with a lower attenuation difference between the two CT scans, mixed-effect model analysis was performed with ROI-level (slice thickness, shape, intravertebral levels) and patient-level (age, sex, patient diameter, change in CT machine) factors. The root-mean-square standard deviation (RMSSD) and area under the receiver-operating-characteristic curve (AUROC) were calculated.

RESULTS: In total, 73 consecutive patients (mean age ± standard deviation, 69 ± 9 years, 38 women) were included. A lower attenuation difference was observed in ROIs in images with slice thicknesses of 1 and 3 mm than that in images with a slice thickness of 5 mm (p < .001), in large elliptical ROIs (p = .007 or < .001, respectively), and in mid- or cranial-level ROIs than that in caudal-level ROIs (p < .001). No patient-level factors were significantly associated with the attenuation difference. Large, elliptical ROIs placed at the mid-level of L1 on images with 1- or 3-mm slice thicknesses yielded RMSSDs of 12.4-12.5 HU and AUROCs of 0.90.

CONCLUSION: The largest possible regions of interest drawn in the mid-level trabecular portion of the L1 vertebra on thin-slice images may yield improvements in the precision of opportunistic screening for osteoporosis via CT.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Park J, Kim Y, Hong S, et al. Regions of interest in opportunistic computed tomography-based screening for osteoporosis: impact on short-term in vivo precision. Skeletal Radiol. 2024. PMID: 39556270. doi:10.1007/s00256-024-04818-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。