文献速递技术与安全腹部胸部CT

深度学习重建对CT检查辐射剂量降低及癌症风险的影响:一项真实世界临床分析

Impact of deep learning reconstruction on radiation dose reduction and cancer risk in CT examinations: a real-world clinical analysis.
PubMed 文献 · Eur Radiol · 2024-11-29

该研究回顾性分析本机构实施深度学习重建前后两个12个月期间接受体部CT的成人患者数据(实施前n=5553,实施后n=5494),经倾向性评分1:1匹配后每组各纳入5247例。结果显示,实施深度学习重建后体部CT总有效剂量从28.1 ± 14.0 mSv降至15.5 ± 10.3 mSv(p < 0.001),降低45%,估计年癌症发生率从0.247%降至0.130%,尤其在年轻女性中更为明显。

要点

  • 深度学习重建使体部CT总有效剂量从28.1 ± 14.0 mSv降至15.5 ± 10.3 mSv,降低45%。
  • 深度学习重建后估计年癌症发生率从0.247%降至0.130%。
  • 辐射诱导癌症风险下降在年轻女性中尤为明显。

核心结论

  • 实施深度学习重建有可能较混合迭代重建将辐射剂量降低45%,并将辐射诱导癌症风险从0.247%降至0.130%。

研究设计与样本

  • 回顾性分析本机构实施深度学习重建前后两个12个月期间的成人患者体部CT扫描数据,实施前阶段(n = 5553)使用混合迭代重建,实施后阶段(n = 5494)常规CT重建过渡为深度学习重建;基于年龄、性别和体重指数进行1:1倾向性评分匹配,最终每组各5247例纳入分析;收集剂量数据以估算器官特异性当量剂量和总有效剂量,并估算每次CT检查的终生归因风险(LAR)及辐射诱导癌症数量。

诊断标准与关键数值

  • 倾向性评分匹配后每组各5247例;实施深度学习重建后体部CT总有效剂量为15.5 ± 10.3 mSv,实施前为28.1 ± 14.0 mSv(p < 0.001),降低45%。
  • 估计年癌症发生率从实施前0.247%降至实施后0.130%。

临床应用与阅片要点

  • 作者指出,在临床实践中采用深度学习重建可大幅降低CT检查的辐射暴露和癌症风险,提高患者安全,尤其对年轻女性更为重要,并强调先进影像技术的重要性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The purpose of this study is to estimate the extent to which the implementation of deep learning reconstruction (DLR) may reduce the risk of radiation-induced cancer from CT examinations, utilizing real-world clinical data.

METHODS: We retrospectively analyzed scan data of adult patients who underwent body CT during two periods relative to DLR implementation at our facility: a 12-month pre-DLR phase (n = 5553) using hybrid iterative reconstruction and a 12-month post-DLR phase (n = 5494) with routine CT reconstruction transitioning to DLR. To ensure comparability between two groups, we employed propensity score matching 1:1 based on age, sex, and body mass index. Dose data were collected to estimate organ-specific equivalent doses and total effective doses. We assessed the average dose reduction post-DLR implementation and estimated the Lifetime Attributable Risk (LAR) for cancer per CT exam pre- and post-DLR implementation. The number of radiation-induced cancers before and after the implementation of DLR was also estimated.

RESULTS: After propensity score matching, 5247 cases from each group were included in the final analysis. Post-DLR, the total effective body CT dose significantly decreased to 15.5 ± 10.3 mSv from 28.1 ± 14.0 mSv pre-DLR (p < 0.001), a 45% reduction. This dose reduction significantly lowered the radiation-induced cancer risk, especially among younger women, with the estimated annual cancer incidence from 0.247% pre-DLR to 0.130% post-DLR.

CONCLUSION: The implementation of DLR has the possibility to reduce radiation dose by 45% and the risk of radiation-induced cancer from 0.247 to 0.130% as compared with the iterative reconstruction.

KEY POINTS: Question Can implementing deep learning reconstruction (DLR) in routine CT scans significantly reduce radiation dose and the risk of radiation-induced cancer compared to hybrid iterative reconstruction? Findings DLR reduced the total effective body CT dose by 45% (from 28.1 ± 14.0 mSv to 15.5 ± 10.3 mSv) and decreased estimated cancer incidence from 0.247 to 0.130%. Clinical relevance Adopting DLR in clinical practice substantially lowers radiation exposure and cancer risk from CT exams, enhancing patient safety, especially for younger women, and underscores the importance of advanced imaging techniques.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kobayashi N, Nakaura T, Yoshida N, et al. Impact of deep learning reconstruction on radiation dose reduction and cancer risk in CT examinations: a real-world clinical analysis. Eur Radiol. 2024. PMID: 39613960. doi:10.1007/s00330-024-11212-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。