CT引导下诺西那生钠鞘内注射过程中介入放射科医生辐射暴露的实时测量
该研究连续分析了40例CT引导下诺西那生钠鞘内注射,实时测量操作者辐射暴露。医生铅围裙下辐射剂量中位数为0.20 µSv,患者剂量以DLP计中位数为31.90 mGy*cm。脊柱内固定患者的辐射剂量显著更高(p=0.047)。结论认为该操作对操作者辐射暴露相对安全,可允许介入放射科医生执行更多操作而不超过年剂量限值。
要点
- 医生铅围裙下辐射剂量中位数为0.20 µSv,患者DLP中位数为31.90 mGy*cm。
- 脊柱内固定患者的辐射剂量显著高于无内固定患者(p=0.047)。
- CT引导下诺西那生钠鞘内注射对操作者辐射暴露相对安全。
核心结论
- CT引导下诺西那生钠鞘内注射对操作者辐射暴露相对安全,可允许介入放射科医生执行更多操作而不超过年剂量限值。
研究设计与样本
- 连续纳入40例CT引导下诺西那生钠鞘内注射,实时测量操作者辐射暴露。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Some patients with spinal muscular atrophy and scoliosis require CT guidance during injections of nusinersen. The radiation applied to the operator in such procedures becomes an important issue in terms of staff health and safety. The aim of the study was to assess the operator's radiation exposure during CT-guided nusinersen injections in patients with spinal muscular atrophy and scoliosis.
METHODS: Consecutive 40 CT-guided nusinersen injections were analyzed in terms of operator's radiation exposure measured in real time.
RESULTS: The median radiation dose measured under the physician's lead apron and patient dose in terms of DLP was 0.20 µSv and 31.90 mGy*cm respectively. The radiation doses were significantly higher (p = 0.047) in patients with spinal instrumentation.
CONCLUSION: The results show that CT-guided nusinersen injection is a relatively safe procedure in terms of operator's radiation exposure. This can allow for interventional radiologists to perform more procedures without exceeding their annual dose limit.
引用
- Rosiak G, Franke J, Milczarek K, et al. Real-time measurement of radiation exposure in interventional radiologists during CT-guided intrathecal injections of nusinersen. Neuroradiology. 2024. PMID: 39514033. doi:10.1007/s00234-024-03496-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。