文献速递介入腹部外周血管DSACT

左桡动脉与右股动脉入路在c-TACE手术中操作者辐射暴露与患者舒适度的比较

Left radial vs right femoral: comparison between arterial accesses in c-TACE procedures in terms of operator radiations exposure and patient comfort.
PubMed 文献 · Radiol Med · 2024-11-04

这项多中心前瞻性随机研究比较了左桡动脉入路与右股动脉入路在常规经动脉化疗栓塞术中的操作者辐射暴露、患者舒适度、技术成功率和血管入路并发症。结果显示两组在操作者辐射暴露、透视时间和技术成功率上无统计学差异,但桡动脉入路组患者舒适度显著更高。

要点

  • 左桡动脉与右股动脉入路在c-TACE中操作者辐射暴露无显著差异(P>0.05)。
  • 两组技术成功率分别为股动脉组81.5%和桡动脉组84.8%,无显著差异(P>0.05)。
  • 桡动脉入路组患者不适感显著高于股动脉组(P<0.05),原文表述为患者不适在F组显著更高。

核心结论

  • 左桡动脉入路与右股动脉入路在c-TACE中操作者辐射暴露、透视时间和技术成功率均无统计学差异,桡动脉入路患者舒适度显著更好。

研究设计与样本

  • 多中心前瞻性随机研究,纳入中期或既往分期不适合消融和/或手术的肝细胞癌患者,随机分为右股动脉入路组(F组,23例)和左臂外展90°桡动脉入路组(R组,19例)。
  • 记录总透视时间,每次手术前放置8个热释光剂量计监测辐射剂量,技术成功定义为最终平扫锥形束CT上肝细胞癌结节完全碘油沉积。

诊断标准与关键数值

  • 技术成功定义为最终平扫锥形束CT上肝细胞癌结节完全碘油沉积,F组技术成功率81.5%,R组84.8%,差异无统计学意义(P>0.05)。
  • F组平均透视时间低于R组,但差异无统计学意义(P>0.05)。
  • 操作者辐射暴露两组无显著差异(P>0.05)。
  • 患者不适感F组显著高于R组(P<0.05)。
  • 轻微并发症两组无统计学差异(P>0.05),无严重并发症发生。

临床应用与阅片要点

  • 作者认为这些数据应引导介入放射科医生在c-TACE干预中优先选择桡动脉入路。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This multicenter prospective study aims to compare transradial access versus transfemoral access in conventional transarterial chemoembolization (c-TACE) procedures, focusing on operators radiations exposure, patients comfort, technical success and vascular access complications.

MATERIALS AND METHODS: Patients were affected by hepatocellularcarcinoma (HCC) in intermediate stage or previous stages unfit for ablation and/or surgery; they were randomized into two groups according to arterial access site (Group F: right femoral access in standard position; Group R: radial access with left arm abduced 90°). Overall fluoroscopy time was recorded. Eight thermoluminescence dosimeters were positioned immediately before each procedure to monitor radiation doses. Technical success was intended as complete HCC nodules lipiodolization at final plain cone-beam CT.

RESULTS: Group F included 23 patients, while group R 19. Mean fluoroscopy time was lower in group F but difference was not statistically significant (p-value > 0.05). In terms of operators radiations exposure, no significant differences were found (p-value > 0.05). Technical success was obtained in 81.5% in group F and 84.8% in group R, without significant differences (p-value > 0.05). Patients discomfort was significantly (p-value < 0.05) higher in group F. Concerning minor complications, no statistical differences were appreciated (p-value > 0.05); no major complications occurred.

CONCLUSIONS: In this study, no statistical differences were observed in terms of operators radiations exposure, fluoroscopy time and technical success during c-TACE performed with left radial access compared to right femoral access; patients comfort was significantly better with radial access. These data should lead interventional radiologists to favor radial access in c-TACE interventions.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Giurazza F, Vizzuso A, Capussela T, et al. Left radial vs right femoral: comparison between arterial accesses in c-TACE procedures in terms of operator radiations exposure and patient comfort. Radiol Med. 2024. PMID: 39495436. doi:10.1007/s11547-024-01906-8