光子计数CT血管造影在外周动脉疾病中的诊断性能:与DSA金标准对比
本研究回顾性纳入109例外周动脉疾病患者,评估光子计数CT血管造影(PC CTA)及纯 lumen 重建与DSA金标准对比的诊断性能,下肢动脉分为10个节段由两名经验丰富的阅片者独立评估。PC CTA的敏感度、特异度和准确率分别为91%、95%和93%,纯 lumen 重建分别为85%、89%和88%。光子计数CTA对外周动脉狭窄病变检测具有高敏感度和特异度,纯 lumen 重建并未进一步提高准确率。
要点
- PC CTA诊断外周动脉狭窄的敏感度91%、特异度95%、准确率93%。
- PC纯 lumen 重建敏感度85%、特异度89%、准确率88%,未优于PC CTA。
- 两名阅片者间一致性良好至完美(PC CTA κ=0.791;纯 lumen 重建 κ=0.829)。
核心结论
- 光子计数CTA对外周动脉狭窄病变的检测和诊断具有高敏感度和特异度;与PC CTA相比,PC非钙化重建并未进一步提高准确率。
研究设计与样本
- 回顾性分析,纳入2021年11月至2023年11月期间接受PC CTA后行DSA的患者109例(平均年龄74.68±11.10岁;男77例,女32例),经机构审查委员会批准并符合HIPAA;下肢动脉血管分为从髂血管至小腿动脉血管的10个节段,由两名经验丰富的阅片者独立评估;以DSA为金标准。
关键影像表现/征象
- PC CTA可评估933个血管节段,PC纯 lumen 重建可评估780个血管节段。
- PC纯 lumen 重建在91例患者(83%)中可用。
诊断标准与关键数值
- PC CTA对比DSA金标准:敏感度91%、特异度95%、准确率93%。
- PC纯 lumen 重建对比DSA金标准:敏感度85%、特异度89%、准确率88%。
- 阅片者间一致性:PC CTA κ=0.791,PC纯 lumen 重建 κ=0.829。
局限性
- 本文为回顾性分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Photon-counting (PC) CT has the potential to improve diagnostic confidence and image quality of CT angiography (CTA) in patients with peripheral artery disease (PAD).
PURPOSE: To retrospectively evaluate the diagnostic performance of Photon-counting CT angiography for the assessment of stenotic disease in patients with PAD compared to digital subtraction angiography (DSA) as gold standard.
MATERIALS AND METHODS: All patients undergoing PC CTA followed by DSA between November 2021 and November 2023 were included in this institutional review board approved HIPAA compliant retrospective analysis. The arterial vasculature of the lower extremity was divided into 10 segments from the iliac vasculature to the calf arterial vasculature. The images were evaluated independently by two experienced readers. Inter-reader agreement was determined using Cohen's kappa coefficient (κ). Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) as well as accuracy were calculated for PC CTA and PC pure lumen reconstruction compared to DSA as gold standard.
RESULTS: 109 patients (mean age 74.68 ± 11.10 years; 77 males, 32 females) were included in the retrospective analysis. PC pure lumen reconstructions was available for 91 patients (83 %). A total of 933 vascular segments for PC CTA and 780 vascular segments for PC pure lumen reconstruction were evaluated. Good to perfect inter-reader agreement was found for PC CTA (κ = 0.791) and for PC pure lumen reconstruction (κ = 0.829). Sensitivity, Specificity and accuracy for PC CTA were 91 %; 95 % and 93 %, respectively. Sensitivity, Specificity and accuracy for PC pure lumen reconstruction were 85 %, 89 % and 88 %, respectively.
CONCLUSION: Photon-counting CTA demonstrates high sensitivity and specificity for the detection and diagnosis of stenotic lesions in PAD. PC non-calcium reconstruction does not further increase the accuracy compared to PC CTA.