文献速递骨肌神经技术与安全MR

基于深度学习图像重建的加速脊柱MRI:与标准MRI的前瞻性对比研究

Accelerated Spine MRI with Deep Learning Based Image Reconstruction: A Prospective Comparison with Standard MRI.
PubMed 文献 · Acad Radiol · 2024-11-22

前瞻性纳入200例脊柱不适参与者,均行标准与加速两次MRI检查;深度学习重建使扫描时间缩短约40%,SNR和CNR显著高于标准方案(P<0.001),个体等效指数绝对值均小于4%,提示两种方案可互换,主观评分与病灶检出频率无差异。

要点

  • 深度学习重建脊柱MRI扫描时间较标准方案缩短约40%,图像质量满足诊断需求。
  • 深度学习重建的SNR和CNR显著高于标准方案(P<0.001),相似性指标改善0-0.35。
  • 两种方案主观评分与病灶检出频率无差异,个体等效指数绝对值均小于4%提示可互换。

核心结论

  • 与标准方案相比,深度学习重建提供可用于诊断的高质量图像并缩短患者检查时间,在检测多种脊柱异常方面与标准方案可互换。

研究设计与样本

  • 前瞻性研究,2023年7月至2023年8月招募200例有脊柱不适的参与者(男性107例,平均年龄46.56±17.07岁)。
  • 所有参与者均接受标准与加速两次独立MRI检查,计算SNR、CNR及相似性指标进行定量评价。
  • 4名放射科医师进行主观质量与病灶特征评估,采用Wilcoxon检验比较SNR、CNR及主观图像质量的差异。
  • 使用个体等效指数检验脊柱多种病灶的可互换性,计算阅片者间与阅片者内一致性(κ、Kendall τ及W统计量)并行McNemar检验。

诊断标准与关键数值

  • 深度学习重建较标准方案扫描时间缩短约40%。
  • 深度学习重建的SNR和CNR显著高于标准方案(P<0.001)。
  • 深度学习重建在各相似性指标上显示0-0.35的不同程度改善。
  • 所有个体等效指数绝对值均小于4%,表明标准方案与深度学习重建之间可互换。
  • κ与Kendall统计量显示良好至近乎完美的一致性,范围为0.72-0.98。

临床应用与阅片要点

  • 深度学习重建可用于脊柱MRI以缩短检查时间,同时保持与标准方案相当的病灶检出能力。
  • 两种方案主观评分与病灶检出频率无差异,个体等效指数支持其诊断可互换性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate the performance of deep learning (DL) reconstructed MRI in terms of image acquisition time, overall image quality and diagnostic interchangeability compared to standard-of-care (SOC) MRI.

MATERIALS AND METHODS: This prospective study recruited participants between July 2023 and August 2023 who had spinal discomfort. All participants underwent two separate MRI examinations (Standard and accelerated scanning). Signal-to-noise ratios (SNR), contrast-to-noise ratios (CNR) and similarity metrics were calculated for quantitative evaluation. Four radiologists performed subjective quality and lesion characteristic assessment. Wilcoxon test was used to assess the differences of SNR, CNR and subjective image quality between DL and SOC. Various lesions of spine were also tested for interchangeability using individual equivalence index. Interreader and intrareader agreement and concordance (κ and Kendall τ and W statistics) were computed and McNemar tests were performed for comprehensive evaluation.

RESULTS: 200 participants (107 male patients, mean age 46.56 ± 17.07 years) were included. Compared with SOC, DL enabled scan time reduced by approximately 40%. The SNR and CNR of DL were significantly higher than those of SOC (P < 0.001). DL showed varying degrees of improvement (0-0.35) in each of similarity metrics. All absolute individual equivalence indexes were less than 4%, indicating interchangeability between SOC and DL. Kappa and Kendall showed a good to near-perfect agreement in range of 0.72-0.98. There is no difference between SOC and DL regarding subjective scoring and frequency of lesion detection.

CONCLUSION: Compared to SOC, DL provided high-quality image for diagnosis and reduced examination time for patients. DL was found to be interchangeable with SOC in detecting various spinal abnormalities.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Li J, Xia Y, Zhou T, et al. Accelerated Spine MRI with Deep Learning Based Image Reconstruction: A Prospective Comparison with Standard MRI. Acad Radiol. 2024. PMID: 39580249. doi:10.1016/j.acra.2024.11.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。