文献速递骨肌USMR

剪切波弹性成像评估2型糖尿病患者半月板弹性的研究

Evaluation of Meniscus Elasticity with Shear Wave Elastography in Patients with Type 2 Diabetes Mellitus.
PubMed 文献 · Acad Radiol · 2024-10-26

本研究于2024年6月至9月纳入40例2型糖尿病患者与40名健康对照,使用剪切波弹性成像测量双膝内、外侧半月板刚度,并以MRI评估半月板病变。糖尿病患者双侧半月板刚度值高于对照组,差异有统计学意义;半月板刚度值与空腹血糖及HA1c呈中度至强正相关。

要点

  • 2型糖尿病患者双侧半月板剪切波弹性成像刚度值高于健康对照,差异有统计学意义。
  • 糖尿病患者半月板刚度值与空腹血糖及HA1c呈中度至强正相关。
  • 糖尿病组与对照组半月板厚度无显著差异。

核心结论

  • 糖尿病患者半月板刚度增高,剪切波弹性成像可作为检测糖尿病相关半月板病变的定量影像方法。

研究设计与样本

  • 研究纳入40例2型糖尿病患者(20男、20女)和40名健康对照(20男、20女),于2024年6月至9月对双膝内、外侧半月板行剪切波弹性成像检查,所有受试者均行MRI评估半月板病变,灰度超声冠状面测量半月板厚度。

关键影像表现/征象

  • 糖尿病组与对照组半月板厚度无显著差异(p > 0.05)。
  • 糖尿病患者双侧半月板刚度值高于对照组,差异有统计学意义(p < 0.05)。
  • 糖尿病患者半月板刚度值与空腹血糖及HA1c呈中度至强正相关(p < 0.05)。

诊断标准与关键数值

  • 剪切波弹性成像测量范围设为0-8.2m/s和0-200kPa,在冠状面将2 mm ROI置于双膝内、外侧半月板体部。
  • 半月板刚度值测量三次,记录三次测量的均值。

临床应用与阅片要点

  • 剪切波弹性成像可定量评估半月板刚度,为糖尿病相关半月板病变提供影像学参考。
  • 测量时采用冠状面、2 mm ROI置于半月板体部,取三次测量均值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: We aimed to evaluate possible elasticity changes in the menisci of patients with type 2 diabetes mellitus using shear wave elastography (SWE).

MATERIALS AND METHODS: The medial and lateral menisci of the right and left knee of 40 patients (20 males, 20 females) with type 2 diabetes mellitus and 40 healthy controls (20 males, 20 females) were evaluated between June 2024 and September 2024. All patients and the control group were evaluated with MRI for meniscal pathology. Medial and lateral meniscal thicknesses were measured in the coronal plane in grayscale US mode. In both groups, the SWE measurement range was set to 0-8.2m/s and 0-200kPa and 2 mm ROIs were placed on the medial and lateral meniscal bodies of both knees in the coronal plane. The stiffness values of the meniscus were measured three times and the mean value of these three measurements was recorded.

RESULTS: There was no significant difference between meniscal thickness in diabetic patients and control group (p > 0.05). Bilateral meniscal stiffness values of diabetic patients were higher than the control group and there was a statistically significant difference (p < 0.05). There were moderate to strong positive correlations between meniscal stiffness values and fasting blood glucose and HA1c values in the diabetic patients(p < 0.05).

CONCLUSION: This is the first study to demonstrate that meniscus stiffness increases in diabetic patients. SWE is a quantitative imaging method that can be used to detect meniscal pathologies that may develop due to diabetes.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Gurun E, Sanibas AV, Tekgoz M, et al. Evaluation of Meniscus Elasticity with Shear Wave Elastography in Patients with Type 2 Diabetes Mellitus. Acad Radiol. 2024. PMID: 39490319. doi:10.1016/j.acra.2024.10.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。