文献速递乳腺US

超声S-detect系统可提高经验较少放射科医生鉴别乳腺肿块的诊断效能:一项回顾性双中心研究

Ultrasound S-detect system can improve diagnostic performance of less experienced radiologists in differentiating breast masses: a retrospective dual-centre study.
PubMed 文献 · Br J Radiol · 2025-01-01

该双中心回顾性研究纳入296个乳腺肿块(150个良性、146个恶性)的超声图像,比较6名放射科医生单独判读、S-detect系统单独判读及医生联合S-detect系统的诊断效能。医生联合S-detect系统后平均假阴性率降低10.7%(P<.001),AUC从0.743升至0.788(P<.001)。作者结论认为联合S-detect系统时医生对恶性乳腺肿块的诊断表现优于单独判读。

要点

  • 医生联合S-detect系统后平均假阴性率降低10.7%(P<.001),AUC从0.743升至0.788(P<.001)。
  • 888幅医生判读图像中77幅经S-detect系统辅助后由假阳性转为真阴性或由假阴性转为真阳性,39幅发生负向改变。
  • 作者报告低至中等水平放射科医生的敏感度和AUC改善尤为明显。

核心结论

  • 医生联合S-detect系统诊断超声图像上的恶性乳腺肿块表现优于未联合S-detect系统。

研究设计与样本

  • 回顾性双中心研究,共纳入296个乳腺肿块(150个良性、146个恶性)的超声图像,来自2个医疗中心。
  • 6名来自2个中心的放射科医生独立分析超声图像并将每个肿块分为2-5类,随后使用S-detect系统重新复核图像。
  • 比较医生单独判读、S-detect系统单独判读及医生联合S-detect系统的诊断价值。

诊断标准与关键数值

  • 医生联合S-detect系统后平均假阴性率降低10.7%(P<.001),AUC从0.743升至0.788(P<.001)。
  • 888幅医生判读图像中77幅经S-detect系统辅助后发生正向改变(由假阳性转为真阴性或由假阴性转为真阳性),39幅发生负向改变。

临床应用与阅片要点

  • 作者报告低至中等水平放射科医生联合S-detect系统后敏感度和AUC改善尤为明显。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the performance of radiologists when assisted by an S-detect system with that of radiologists or an S-detect system alone in diagnosing breast masses on US images in a dual-centre setting.

METHODS: US images were retrospectively identified 296 breast masses (150 benign, 146 malignant) by investigators at 2 medical centres. Six radiologists from the 2 centres independently analysed the US images and classified each mass into categories 2-5. The radiologists then re-reviewed the images with the use of the S-detect system. The diagnostic value of radiologists alone, S-detect alone, and radiologists + S-detect were analysed and compared.

RESULTS: Radiologists had significantly decreased the average false negative rate (FNR) for diagnosing breast masses using S-detect system (-10.7%) (P < .001) and increased the area under the receiver operating characteristic curve (AUC) from 0.743 to 0.788 (P < .001). Seventy-seven out of 888 US images from 6 radiologists in this study were changed positively (from false positive to true negative or from false negative to true positive) with the S-detect, whereas 39 out of 888 US images were altered negatively.

CONCLUSION: Radiologists had better performance for the diagnosis of malignant breast masses on US images with an S-detect system than without.

ADVANCES IN KNOWLEDGE: The study reported an improvement in sensitivity and AUC particularly for low to intermediate-level radiologists, involved cases and radiologists from 2 different centres, and compared the diagnostic value of using S-detect system for masses of different sizes.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Du L, Liu H, Cai M, et al. Ultrasound S-detect system can improve diagnostic performance of less experienced radiologists in differentiating breast masses: a retrospective dual-centre study. Br J Radiol. 2025. PMID: 39535865. doi:10.1093/bjr/tqae233

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。