文献速递乳腺技术与安全US

基于光声成像的瘤内及瘤周影像组学列线图用于术前预测乳腺恶性肿瘤Ki-67表达

Photoacoustic-Based Intra- and Peritumoral Radiomics Nomogram for the Preoperative Prediction of Expression of Ki-67 in Breast Malignancy.
PubMed 文献 · Acad Radiol · 2024-11-20

研究纳入359例乳腺癌患者(训练集251例、测试集108例),从光声成像的瘤内及瘤周区域提取影像组学特征,结合临床特征构建列线图,测试集AUC为0.899,6 mm瘤周区域模型识别Ki-67状态最有效。

要点

  • 光声影像组学列线图联合6 mm瘤周与瘤内特征及临床特征,测试集AUC达0.899。
  • 6 mm瘤周区域在识别乳腺癌Ki-67状态中最有效。
  • 该模型有望作为传统活检的无创辅助工具,助力乳腺癌个体化管理。

核心结论

  • 整合光声影像组学与临床特征可为术前预测乳腺癌Ki-67状态提供稳健工具,优化瘤周区域勾画以提高诊断精度,模型表现支持其作为传统活检的无创辅助工具的潜力,有助于乳腺癌治疗的个体化管理。

研究设计与样本

  • 本研究纳入359例患者,分为训练集251例和测试集108例,采用光声成像提取瘤内及瘤周区域影像组学特征,以多变量逻辑回归识别显著临床因素,LASSO回归在训练集筛选特征,将所选影像组学特征与临床特征结合构建影像组学列线图,以受试者工作特征曲线下面积(AUC)评估预测效能,并通过决策曲线分析和校准曲线分别评估临床效用与准确性。

诊断标准与关键数值

  • 所构建列线图联合6 mm瘤周数据与瘤内及临床特征,测试集AUC为0.899,校准良好,表现优于仅基于临床特征或其他影像组学方法的模型,6 mm瘤周区域在识别乳腺癌患者Ki-67状态中最有效。

临床应用与阅片要点

  • 作者认为,整合光声影像组学与临床特征可为术前预测乳腺癌Ki-67状态提供稳健工具,优化瘤周区域勾画以提高诊断精度,模型表现支持其作为传统活检的无创辅助工具的潜力,有助于乳腺癌治疗的个体化管理。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: This study investigated the preoperative predictive efficiency of radiomics derived from photoacoustic (PA) imaging, integrated with the clinical features of Ki-67 expression in malignant breast cancer (BC), with a focus on both intratumoral and peritumoral regions.

METHODS: This study involved 359 patients, divided into a training set (n = 251) and a testing set (n = 108). Radiomic features were extracted from intratumoral and peritumoral regions using PA imaging. Multivariate logistic regression was employed to identify significant clinical factors. LASSO regression was used to select the features extracted from the training set. The selected radiomics features were combined with clinical features to develop a radiomics nomogram. The predictive efficiency of the model was assessed using the area under the receiver operating characteristic curve (AUC), and its clinical utility and accuracy were evaluated through decision curve analysis and calibration curves, respectively.

RESULTS: The developed nomogram combined 6 mm peritumoral data with intratumoral and clinical features and showed excellent diagnostic performance, achieving an AUC of 0.899 in the testing set. They both showed good calibrations. The outperformed models based solely on clinical features or other radiomics methods, with the 6 mm surrounding tumor area proving most effective in identifying Ki-67 status in BC patients.

CONCLUSION: Integrating PA radiomics with clinical features offers a robust preoperative tool for predicting Ki-67 status in BC, optimizing the delineation of peritumoral regions for enhanced diagnostic precision. The model's strong performance supports its potential as a non-invasive adjunct to traditional biopsy methods, aiding in the personalized management of BC treatment.

来源:Acad Radiol,查看原文。版权归原作者所有。