文献速递乳腺乳腺X线

深度学习算法在英国筛查队列中的乳腺癌检测:作为独立阅片者及与人工阅片者联合应用

Deep Learning Algorithms for Breast Cancer Detection in a UK Screening Cohort: As Stand-alone Readers and Combined with Human Readers.
PubMed 文献 · Radiology · 2024-01-01

该研究回顾性纳入英国两个中心2017年全年连续的全视野数字乳腺摄影病例26722例,外部验证三种商业深度学习算法作为独立阅片者及与人工阅片者联合应用的性能。结果显示,三种算法与人工阅片联合的敏感度均非劣于双人阅片,特异度均优于双人阅片。

要点

  • 三种深度学习算法与人工阅片联合的敏感度均非劣于双人阅片(67.4%)。
  • 三种算法联合人工阅片的特异度均优于双人阅片(97.1%)。
  • 独立阅片时,DL-1和DL-2的敏感度非劣于首位人工阅片者,DL-3未达非劣效。

核心结论

  • 独立深度学习算法联合人工阅片可在减少工作量的同时维持筛查准确性。

研究设计与样本

  • 回顾性研究,纳入英国两个中心2017年全年连续采集的全视野数字乳腺摄影病例26722例(患者中位年龄59.0岁,IQR 54.0-63.0岁),使用两家厂商的设备,以敏感度和特异度为主要指标,非劣效检验P<.025为有统计学意义。

诊断标准与关键数值

  • 独立阅片敏感度:DL-1 64.8%(P<.001)、DL-2 56.7%(P=.03)、DL-3 58.9%(P<.001),对照首位人工阅片者62.8%;独立阅片特异度:DL-1 92.8%(P<.001)、DL-2 96.8%(P<.001)非劣于、DL-3 97.9%(P<.001)优于首位人工阅片者96.5%。联合阅片敏感度:DL-1 67.0%、DL-2 65.6%、DL-3 65.4%(P均<.001),对照双人阅片67.4%;联合阅片特异度:DL-1 97.4%、DL-2 97.6%、DL-3 97.6%(P均<.001),优于双人阅片97.1%。

临床应用与阅片要点

  • 作者认为,独立深度学习算法联合人工阅片可在减少工作量的同时维持筛查准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Deep learning (DL) algorithms have shown promising results in mammographic screening either compared to a single reader or, when deployed in conjunction with a human reader, compared with double reading. Purpose To externally validate the performance of three DL algorithms as mammographic screen readers in an independent UK data set. Materials and Methods Three commercial DL algorithms (DL-1, DL-2, and DL-3) were retrospectively investigated from January 2022 to June 2022 using consecutive full-field digital mammograms collected at two UK sites during 1 year (2017). Normal cases with 3-year follow-up and histopathologically proven cancer cases detected either at screening (that round or next) or within the 3-year interval were included. A preset specificity threshold equivalent to a single reader was applied. Performance was evaluated for stand-alone DL reading compared with single human reading, and for DL reading combined with human reading compared with double reading, using sensitivity and specificity as the primary metrics. P < .025 was considered to indicate statistical significance for noninferiority testing. Results A total of 26 722 cases (median patient age, 59.0 years [IQR, 54.0-63.0 years]) with mammograms acquired using machines from two vendors were included. Cases included 332 screen-detected, 174 interval, and 254 next-round cancers. Two of three stand-alone DL algorithms achieved noninferior sensitivity (DL-1: 64.8%, P < .001; DL-2: 56.7%, P = .03; DL-3: 58.9%, P < .001) compared with the single first reader (62.8%), and specificity was noninferior for DL-1 (92.8%; P < .001) and DL-2 (96.8%; P < .001) and superior for DL-3 (97.9%; P < .001) compared with the single first reader (96.5%). Combining the DL algorithms with human readers achieved noninferior sensitivity (67.0%, 65.6%, and 65.4% for DL-1, DL-2, and DL-3, respectively; P < .001 for all) compared with double reading (67.4%), and superior specificity (97.4%, 97.6%, and 97.6%; P < .001 for all) compared with double reading (97.1%). Conclusion Use of stand-alone DL algorithms in combination with a human reader could maintain screening accuracy while reducing workload. Published under a CC BY 4.0 license. Supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Hickman SE, Payne NR, Black RT, et al. Deep Learning Algorithms for Breast Cancer Detection in a UK Screening Cohort: As Stand-alone Readers and Combined with Human Readers. Radiology. 2024. PMID: 39560480. doi:10.1148/radiol.233147

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。