文献速递乳腺MR

乳腺MR检查中BI-RADS 4和5类病变应用归纳式机器学习模型区分良性、高危病变和恶性肿瘤的准确性

Accuracy of distinguishing benign, high-risk lesions and malignancies with inductive machine learning models in BIRADS 4 and BIRADS 5 lesions on breast MR examinations.
PubMed 文献 · Eur J Radiol · 2024-10-24

本研究分析114例患者124个经组织学证实的BI-RADS 4或5类乳腺MR病变,使用归纳决策树模型(C5.0结合AdaBoost)联合SMOTE及LCC数据平衡方法构建良性、B3或恶性三分类模型,最优模型分类准确率88.70%、平均敏感度97.18%、特异度98.59%。

要点

  • 归纳决策树模型联合LCC数据平衡方法对BI-RADS 4/5类乳腺MR病变的三分类准确率达88.70%。
  • 最优模型平均敏感度97.18%、特异度98.59%,基于10个影像参数和1个临床观察指标。
  • 模型性能经10折交叉验证、留一法及12例未知测试集评估。

核心结论

  • 初步研究表明,基于乳腺MR提取数据,归纳决策树模型有潜力准确区分良性、B3和恶性病变,最优模型分类准确率88.70%、平均敏感度97.18%、特异度98.59%。

研究设计与样本

  • 回顾性分析114例患者124个经组织学证实的BI-RADS 4或5类乳腺MR病变,使用归纳决策树模型(C5.0算法以AdaBoost增强)联合SMOTE及LCC数据平衡方法构建三分类模型,训练集112例12个变量,模型性能采用10折交叉验证、留一法及12例未知测试集评估。

诊断标准与关键数值

  • 最优分类模型(归纳决策树联合LCC数据平衡方法)区分良性、B3和恶性病变的分类准确率88.70%、平均敏感度97.18%、特异度98.59%。

局限性

  • 本研究为初步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: The aim of this study is to explore the utility of Inductive Decision Tree models (IDTs) in distinguishing between benign, malignant, and high-risk (B3) breast lesions.

MATERIALS AND METHODS: We analyzed 124 histologically confirmed lesions in 114 patients who underwent breast MR with BI-RADS 4 or 5 assessment. The dataset comprised 10 imaging parameters and one clinical observation. Using the IDTs method (algorithm C5.0 boosted with AdaBoost algorithm) combined with the data balancing method SMOTE (Synthetic Minority Oversampling Technique) and a corresponding new method called LCC (Leveling of Cases per Class), we developed corresponding 3-class classification models (Benign, B3, or Malignant). The training set used for classification model development consists of 112 cases with 12 variables, and the model's performance was assessed using 10-fold Cross-Validation and Leave-One-Out methods (utilizing the training set) and the Use Test Set method (testing on an unknown (for the models) dataset of 12 cases with 12 variables).

RESULTS: This preliminary study demonstrates the potential for IDTs to accurately distinguish between benign, B3 and Malignant lesions based on extracted data from breast MRI exams with a high classification accuracy (88.70 %), mean sensitivity of 97.18 % and specificity of 98.59 % achieved by the optimal classification model, derived from the combination of the IDTs method and the LCC data balancing method.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Panourgias E, Karampotsis E, Douma N, et al. Accuracy of distinguishing benign, high-risk lesions and malignancies with inductive machine learning models in BIRADS 4 and BIRADS 5 lesions on breast MR examinations. Eur J Radiol. 2024. PMID: 39514933. doi:10.1016/j.ejrad.2024.111801

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。