文献速递乳腺乳腺X线

乳腺筛查数字乳腺断层摄影序贯阅片过程中阅片者表现的变化

Changes in Reader Performance During Sequential Reading of Breast Cancer Screening Digital Breast Tomosynthesis Examinations.
PubMed 文献 · Radiology · 2024-01-01

该观察性回顾性研究分析2018年1月至2019年12月121652例筛查数字乳腺断层摄影检查,由15名放射科医生阅片,评估批次内序贯阅片位置对表现的影响。未调整假阳性率从批次内第1例平均15.5%降至连续阅读3例后10.5%(P < .001),敏感度无显著变化(82.6% vs 84.2%;P = .15),阅片时间缩短。调整混杂后假阳性率11.5%降至9.4%(P < .001),非癌病例阅片时间3.2分钟降至2.7分钟(P < .001)。

要点

  • 批次内序贯阅片位置越靠后,假阳性率越低而敏感度无显著变化。
  • 非癌病例阅片时间随批次内序贯位置延长而缩短。
  • 调整患者与阅片因素后假阳性率下降与时间缩短仍存在。

核心结论

  • 放射科医生在数字乳腺断层摄影筛查批次阅片过程中,召回率与阅片时间改善而敏感度无变化。

研究设计与样本

  • 观察性回顾性研究,使用放射信息系统数据,纳入2018年1月至2019年12月筛查数字乳腺断层摄影检查121652例(患者中位年龄61岁,IQR 53-69岁),由15名放射科医生阅片,含1081例癌症;参考标准基于病理结果(适用时)或1年随访影像表现;检查按同一阅片者相邻检查时间差10分钟以内聚合为批次;采用混合效应模型评估批次位置间表现与时间,并调整患者特征(年龄、乳腺密度)、阅片因素(星期几、一天中时间)及阅片者间异质性等潜在混杂。

诊断标准与关键数值

  • 未调整假阳性率从批次内第1例检查平均15.5%降至连续阅读3例后10.5%(P < .001)。
  • 敏感度从82.6%至84.2%(P = .15),无显著变化。
  • 非癌检查平均阅片时间从2.8分钟降至2.2分钟(P < .001)。
  • 调整抽样偏倚与混杂因素后假阳性率从11.5%降至9.4%(连续阅读3例后;P < .001)。
  • 调整后非癌检查阅片时间从3.2分钟降至2.7分钟(P < .001)。

临床应用与阅片要点

  • 批次内序贯阅片时,后续病例的假阳性率较低而敏感度未见显著下降,阅片报告时可关注批次位置对判读的影响。
  • 非癌病例的阅片时间随批次内序贯位置延长而缩短,提示阅片效率随批次推进而提高。
  • 患者年龄、乳腺密度、星期几、一天中时间均为显著混杂因素(均P < .005),解读批次效应时需考虑这些因素。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Studies suggest that readers experience perceptual adaptation when interpreting batched screening mammograms, which may serve as a mechanism for improved performance. Purpose To analyze clinical digital breast tomosynthesis (DBT) screening data to evaluate changes in reader performance during sequential batch reading. Materials and Methods This observational retrospective study used data from the radiology information system collected for screening DBT examinations performed from January 2018 to December 2019. The reference standard was established based on pathology results, if applicable, or imaging findings at 1-year follow-up. Examinations were aggregated into batches, defined as a sequence of cases for a given reader with differences in interexamination time of 10 minutes or less. Mixed-effect models were used to evaluate performance and timing across batch positions. Statistical adjustments accounted for potential confounders, including patient characteristics (age, breast density), reading factors (day of week, time of day), and between-reader heterogeneity. Results The dataset included 121 652 examinations (median patient age, 61 years [IQR, 53-69 years]), including 1081 cancers interpreted by 15 radiologists. Unadjusted false-positive rates decreased from an averaged 15.5% at the first within-batch examination to 10.5% after three sequentially read examinations (P < .001), without a significant change in sensitivity (82.6% vs 84.2%; P = .15). The interpretation time consistently decreased, achieving a substantial reduction in longer batches (average 2.8 to 2.2 minutes for noncancer examinations; P < .001). Adjustment for sampling bias and confounders (patient age, breast density, day of week, time of day; all P < .005) reduced the effect on false-positive rates (11.5% to 9.4% after three examinations; P < .001) and interpretation time (3.2 to 2.7 minutes for noncancer examinations; P < .001). Conclusion Radiologists showed improved recall rates and interpretation times without change in sensitivity over the course of batch reading of DBT screening examinations. © RSNA, 2024 See also the editorial by Iima and Satake in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Abbey CK, Bandos AI, Parthasarathy MK, et al. Changes in Reader Performance During Sequential Reading of Breast Cancer Screening Digital Breast Tomosynthesis Examinations. Radiology. 2024. PMID: 39530892. doi:10.1148/radiol.232885

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。