基于超声影像组学的新型列线图用于预测冻融胚胎移植周期后的宫内妊娠
本研究纳入211例冻融胚胎移植前子宫内膜转化日行超声检查的患者,基于9个影像组学特征计算Rad-score并联合临床因素构建列线图,预测宫内妊娠。Rad-score在训练、验证及合并队列的AUC分别为0.72、0.65、0.69,联合列线图AUC分别提高至0.81、0.67、0.77,决策曲线分析显示列线图具有临床实用性。
要点
- 基于子宫内膜超声影像组学的Rad-score在训练、验证和合并队列的AUC分别为0.72、0.65和0.69。
- Rad-score联合临床因素构建的列线图将训练、验证和合并队列AUC分别提高至0.81、0.67和0.77。
- 决策曲线分析显示影像组学列线图具有临床实用性。
核心结论
- 影像组学与临床预测列线图能有效预测体外冻融胚胎移植后的宫内妊娠,并可进一步应用于临床策略。
研究设计与样本
- 研究纳入211例在冻融胚胎移植周期前子宫内膜转化日行超声检查的患者,按超声结果分为宫内妊娠组和妊娠失败组,采用单因素及多因素logistic回归分析临床特征和影像组学特征,基于影像组学标签和显著临床因素建立列线图预测模型,并在训练队列和外部验证队列中评估模型稳健性。
诊断标准与关键数值
- 采用最小绝对收缩和选择算子(LASSO)筛选出9个影像组学特征,影像组学评分(Rad-score)按各特征乘以LASSO非零系数后求和计算;基于Rad-score的ROC曲线AUC在训练、验证和合并队列分别为0.72、0.65和0.69;Rad-score联合临床因素构建的列线图AUC在训练、验证和合并队列分别提高至0.81、0.67和0.77。
临床应用与阅片要点
- 决策曲线分析显示影像组学列线图具有临床实用性;原文结论认为该列线图可进一步应用于临床策略。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to develop a nomogram for predicting intrauterine pregnancy after an in vitro frozen embryo transfer cycle using endometrial ultrasound radiomics.
METHODS: A total of 211 patients who underwent ultrasound examination on the day of endometrial transformation before the frozen embryo transfer cycle were enrolled. The patients were divided into an intrauterine pregnancy group and a pregnancy failure group based on ultrasound results. Clinical characteristics and radiomic features were analyzed using univariate and multivariate logistic regression analyses. A nomogram prediction model was established based on radiomic signatures and significant clinical factors. The model's robustness was assessed in training and external validation cohorts.
RESULTS: Nine radiomic features were selected using least absolute shrinkage and selection operator (LASSO), and the radiomics score (Rad-score) was calculated as the sum of each feature multiplied by the nonzero coefficient from LASSO. The area under the curve (AUC) of the receiver operating characteristic (ROC) curve based on the Rad-score was 0.72, 0.65, and 0.69 in the training, validation, and combined cohorts, respectively. To improve diagnostic efficiency, the Rad-score was further integrated with clinical factors to form a novel predictive nomogram. The results indicated that the AUC increased to 0.81, 0.67, and 0.77 in the training, validation, and combined cohorts, respectively. Decision curve analysis showed that the radiomics nomogram was clinically useful.
CONCLUSION: The radiomics and clinical predictive nomogram can effectively predict intrauterine pregnancy after in vitro frozen embryo transfer and can be further applied in clinical strategy.
引用
- Yang X, Zheng Y, Li X, et al. Development of a Novel Nomogram Based on Ultrasonic Radiomics for Predicting Intrauterine Pregnancy After Frozen Embryo Transfer Cycle. J Ultrasound Med. 2024. PMID: 39611390. doi:10.1002/jum.16625
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。