文献速递泌尿生殖妇产影像MR

卵巢扭转的磁共振成像特征:对诊断要点的深入探讨

Magnetic resonance imaging characteristics of ovarian torsion: insights into diagnostic features.
PubMed 文献 · Abdom Radiol (NY) · 2024-11-26

该回顾性研究分析了34例附件扭转患者的MRI,系统比较扭转侧与非扭转侧附件在漩涡征、子宫偏移、间质水肿等征象上的差异,并测量卵巢大小及间质ADC值;结果显示除卵泡边缘征外各征象差异均有统计学意义,漩涡征准确率最高(0.93),扭转侧卵巢最大径及间质ADC值均显著大于非扭转侧。

要点

  • 漩涡征准确率最高(0.93),其次为子宫偏移和间质水肿(均为0.85),支持附件扭转诊断。
  • 扭转侧卵巢最大径平均67.5 ± 16.3 mm,显著大于非扭转侧的38.8 ± 7.7 mm(p < 0.001)。
  • 扭转侧卵巢间质ADC值平均1930.5 ± 455.4(10⁻⁶ mm²/s),显著高于非扭转侧的1655.7 ± 349.3(10⁻⁶ mm²/s)(p < 0.001)。

核心结论

  • 基于准确率,附件扭转最可靠的指标包括卵巢增大、漩涡征、子宫偏移和间质水肿。

研究设计与样本

  • 回顾性分析34例附件扭转患者的34个扭转附件MRI,系统比较扭转侧与非扭转侧附件的影像征象,并测量卵巢大小及间质ADC值。

关键影像表现/征象

  • 除卵泡边缘征外,扭转侧与非扭转侧附件在周围移位卵泡征、间质水肿、间质缺乏对比增强、卵泡边缘征、T2低信号边缘征、子宫偏移、附件移位、漩涡征、T2低信号点征及输卵管增厚上差异均有统计学意义。
  • 漩涡征准确率最高(0.93),其次为子宫偏移和间质水肿(均为0.85),间质缺乏对比增强为0.81,T2低信号点征为0.79,周围移位卵泡征为0.77,附件移位和输卵管增厚均为0.66,T2低信号边缘征为0.62,卵泡边缘征为0.54。
  • 扭转侧卵巢最大径平均67.5 ± 16.3 mm,非扭转侧为38.8 ± 7.7 mm(p < 0.001)。
  • 扭转侧卵巢间质ADC值平均1930.5 ± 455.4(10⁻⁶ mm²/s),非扭转侧为1655.7 ± 349.3(10⁻⁶ mm²/s)(p < 0.001)。

诊断标准与关键数值

  • 漩涡征准确率0.93;子宫偏移准确率0.85;间质水肿准确率0.85;间质缺乏对比增强准确率0.81;T2低信号点征准确率0.79;周围移位卵泡征准确率0.77;附件移位准确率0.66;输卵管增厚准确率0.66;T2低信号边缘征准确率0.62;卵泡边缘征准确率0.54。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: We aimed to describe the magnetic resonance imaging (MRI) features of adnexal torsion, additional radiological findings and apparent diffusion coefficient (ADC) measurements of the affected and non-affected ovaries.

METHODS: We retrospectively examined the MRI of 34 torsed adnexa of 34 cases. We specifically examined the peripherally displaced follicle sign, stromal edema, lack of stromal contrast enhancement, follicular rim sign, T2 hypointense rim sign, uterine deviation, adnexal displacement, whirlpool sign, T2 hypointense dot sign, and tubal thickening. These signs were systematically compared between the torsed and non-torsed adnexa. In addition to that, the presence of free fluid was recorded. As a quantitative analysis, ovarian size and stromal ADC values in torsed and non-torsed ovaries were measured.

RESULTS: The average age was 36.6 years. The right ovary was torsed in 21 (61.8%) of the cases, and the left ovary was torsed in 13 (38.2%). There were significant differences between groups in all signs except the follicular rim sign. The highest accuracy was at the whirlpool sign (0.93). This was followed by uterine deviation and stromal edema (0.85). The accuracy rates of other findings are, respectively, lack of stromal contrast enhancement (0.81), T2 hypointense dot sign (0.79), peripherally displaced follicle sign (0.77), displacement of the adnexa (0.66), tubal thickening (0.66), T2 hypointense rim sign (0.62) and follicular rim sign (0.54). The largest size of ovary in patients with torsion was significantly larger, with an average of 67.5 ± 16.3 mm, compared to 38.8 ± 7.7 mm in non-torsed adnexa (p < 0.001). Additionally, the stromal ADC value was significantly higher in torsed ovarian stroma, averaging 1930.5 ± 455.4 (10⁻⁶ mm2/s) compared to 1655.7 ± 349.3 (10⁻⁶ mm2/s) in non-torsed ovarian stroma (p < 0.001).

CONCLUSION: In our study, we conducted a comprehensive evaluation of various imaging signs associated with adnexal torsion. The most reliable indicators of adnexal torsion, based on their high accuracy rates, include an enlarged ovary, the presence of the whirlpool sign, uterine deviation, and stromal edema.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。