文献速递泌尿生殖腹部CT

光子计数探测器CT自动分析肾结石成分的性能研究:一项体模研究

Automated Kidney Stone Composition Analysis with Photon-Counting Detector CT, a Performance Study-A Phantom Study.
PubMed 文献 · Acad Radiol · 2024-11-15

本离体体模研究将148枚经红外光谱确定成分的泌尿系结石置入腹部体模行光子计数探测器CT扫描,自动检测率为86.5%,对尿酸与非尿酸结石鉴别的敏感度66.7%、特异度94.5%、阳性预测值66.7%、阴性预测值94.5%;仅纳入体积大于30 mm³结石时敏感度91.7%、特异度92.4%。

要点

  • 自动检测率随结石增大而提高,直径大于5 mm者达95.4%。
  • 尿酸与非尿酸结石鉴别总体敏感度66.7%、特异度94.5%。
  • 体积大于30 mm³结石鉴别敏感度91.7%、特异度92.4%。

核心结论

  • 光子计数探测器CT自动泌尿系结石成分分析对结石的自动检测率为86.5%至95.4%(取决于结石直径),鉴别尿酸与非尿酸结石的阴性预测值为94.5%、阳性预测值为66.7%,对非尿酸结石的预测概率很好,该自动检测与鉴别算法可识别不会从化学溶石治疗中获益的患者。

研究设计与样本

  • 离体体模研究,共148枚经标准参考方法红外光谱确定成分的泌尿系结石置入腹部体模后行光子计数探测器CT扫描,以红外光谱为参考标准,评估结石检出率及尿酸与非尿酸结石成分预测的准确性。

诊断标准与关键数值

  • 自动检测率:全部结石86.5%,直径大于5 mm为95.4%,大于3 mm为88.8%,大于4 mm为94.7%。
  • 按体积自动检测率:大于20 mm³为92.8%,大于30 mm³为94.0%。
  • 尿酸成分预测总体敏感度66.7%、阳性预测值66.7%、特异度94.5%、阴性预测值94.5%。
  • 仅纳入体积大于30 mm³结石时,敏感度91.7%、特异度92.4%。
  • 按最大直径,敏感度在大于5 mm结石最佳为85.7%,但特异度随直径增大而下降至91.3%。

临床应用与阅片要点

  • 该自动检测与鉴别算法可识别不会从化学溶石治疗中获益的患者。
  • 尿酸与非尿酸结石鉴别总体敏感度66.7%,阅片时需结合结石大小与体积解读结果。
  • 特异度随结石直径增大而下降至91.3%,报告时应注意该变化趋势。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: For treatment of urolithiasis, the stone composition is of particular interest, as uric acid (UA) stones can be treated by chemolitholysis. In this ex vivo study, we employed an advanced composition analysis approach for urolithiasis utilizing spectral data obtained from a photon-counting detector CT (PCDCT) to differentiate UA and non-UA stones. Our primary objective was to assess the accuracy of this analysis method.

METHODS: A total of 148 urinary stones with a known composition that was measured by the standard reference method infrared spectroscopy (reference) were placed in an abdomen phantom and scanned in the PCDCT. Our objectives were to assess the stone detection rates of PCDCT and the accuracy of the prediction of the stone composition in UA vs non-UA compared to the reference.

RESULTS: Automated detection recognized 86.5% of all stones, with best detection rate for stones larger > 5 mm in diameter (95.4%, 88.8% for stones larger than 3 mm, 94.7% for stones larger than 4 mm). Depending on the volume, we found a recognition rate of 92.8% for stones larger than 20 mm3 and 94.0% for stones with more than 30 mm3. Prediction of UA composition showed an overall sensitivity and a positive predictive value of 66.7% and a specificity and negative predictive value of 94.5%. Best diagnostic values volume wise were found by only including stones with a larger volume than 30 mm3, there we found a sensitivity of 91.7%, and a specificity of 92.4%. Sensitivity in dependance of the largest diameter was best for stones larger than 5 mm (85.7%), but specificity decreased with increasing diameter (to 91.3%).

CONCLUSION: Automated urinary stone composition analysis with PCDCT showed a good automated detection rate of 86.5% up to 95.4% depending on stone diameter. The differentiation between non-UA and UA stones is performed with an NPV of 94.5% and a PPV of 66.7%. The prediction probability of non-UA stones was very good. This means the automatic detection and differentiation algorithm can identify the patients which will not profit from chemolitholysis.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Dillinger D, Waldeck S, Overhoff D, et al. Automated Kidney Stone Composition Analysis with Photon-Counting Detector CT, a Performance Study-A Phantom Study. Acad Radiol. 2024. PMID: 39550346. doi:10.1016/j.acra.2024.10.045

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。