文献速递泌尿生殖腹部CT

双能CT表征肾结石成分的可推广框架

A Generalizable Framework for Kidney Stone Composition Characterization Using Dual-Energy CT.
PubMed 文献 · Acad Radiol · 2024-11-04

本研究开发了一个可推广框架,利用半值层测量预测不同结石类型、扫描方案和患者体型下的CT值比值,并在两台双能CT扫描仪上验证。框架对30、40、50 cm体模的预测CT值比值平均绝对误差分别为2.8%、1.8%、1.8%,四种插入物误差在6.4%以内。作者认为经进一步改进,该框架可能有助于临床扫描中对非尿酸结石亚型进行分类。

要点

  • 框架利用半值层测量预测不同成分肾结石的CT值比值,适用于不同体型。
  • 在30、40、50 cm体模中,预测CT值比值的平均绝对误差分别为2.8%、1.8%、1.8%。
  • 四种插入物的预测CT值比值误差在6.4%以内。

核心结论

  • 所开发框架利用易获取的半值层测量预测不同成分肾结石在不同患者体型下的CT值比值;经进一步改进,可能有助于临床扫描中对非尿酸结石亚型进行分类。

研究设计与样本

  • 框架假设通用X射线谱,估计附加滤过以匹配半值层测量,并根据化学成分和患者体型预测各结石类型的CT值比值;在两台双能CT扫描仪上对两种固体水体模尺寸中的四种钙或碘插入物进行验证,并在双源双能CT上对三种不同水体模尺寸中的45枚五种类型人泌尿系结石进行验证;所有扫描均在高剂量下使用常规采集参数进行。

诊断标准与关键数值

  • 预测CT值比值与实验测量值一致,30、40、50 cm体模尺寸的平均绝对误差分别为2.8%(范围1.3-4.3%)、1.8%(范围0.7-4.4%)、1.8%(范围0.8-2.4%)。
  • 四种插入物的预测CT值比值误差在6.4%以内。

局限性

  • 原文结论指出,经进一步改进,该框架可能有助于临床扫描中对非尿酸结石亚型进行分类。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Classification of non-uric acid (NUA) renal stones in dual-energy CT (DECT) is difficult due to their similar CT number ratios (CTRs) and because the CTRs change with patient size and acquisition protocol. In this work, we developed a generalizable framework to estimate correct CTR threshold for different stone types, protocols, and patient sizes and validated the results on two DECT scanners.

MATERIALS AND METHODS: Our framework assumes generic x-ray spectra, estimates the added filtration to match half-value-layer (HVL) measurements, and predicts the CTR of each stone type from the chemical composition and patient size. The framework was validated for four calcium or iodine inserts in two solid water phantom sizes on two DECT scanners, and on 45 human urinary stones of five types (uric acid, cystine, calcium oxalate monohydrate, brushite, and hydroxyapatite) in three different water phantom sizes on a dual-source DECT. All scans were performed at high dose, using routine acquisition parameters. The predicted CTR was compared with the measured CTR.

RESULTS: The predicted CTRs for different stone types were consistent with experimentally measured values, with average absolute errors of 2.8% (range 1.3-4.3%), 1.8% (range 0.7-4.4%), and 1.8% (range 0.8-2.4%) for the 30, 40, and 50 cm phantom sizes. The predicted CTR errors of the four inserts were within 6.4%.

CONCLUSION: The developed framework uses easily obtained HVL measurements to predict renal stone CTRs of different compositions for varied patient sizes. With further refinement, it may help classify NUA subtypes in clinical scans.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Shunhavanich P, Ferrero A, McCollough CH, et al. A Generalizable Framework for Kidney Stone Composition Characterization Using Dual-Energy CT. Acad Radiol. 2024. PMID: 39500640. doi:10.1016/j.acra.2024.10.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。