增强术前诊断胰腺导管腺癌与肿块型慢性胰腺炎:基于归一化常规磁共振成像参数的研究
回顾性纳入经手术病理诊断的170例受试者(肿块型慢性胰腺炎34例、胰腺导管腺癌136例),按性别、年龄和手术时间1:4匹配,计算病灶信号强度与椎旁肌信号强度的比值(SIR)。胰腺导管腺癌组的T1 SIR、动脉期SIR、门静脉期SIR和延迟期SIR显著低于肿块型慢性胰腺炎组,曲线下面积分别约为0.620、0.659、0.670和0.668;作者认为这些参数有潜力作为鉴别两者的影像生物标志物。
要点
- 胰腺导管腺癌的T1、动脉期、门静脉期和延迟期SIR均显著低于肿块型慢性胰腺炎。
- 动脉期SIR鉴别两者AUC为0.659,门静脉期SIR为0.670,延迟期SIR为0.668。
- 各SIR观察者内和观察者间ICC均大于0.8,重复性良好。
核心结论
- T1 SIR、动脉期SIR、门静脉期SIR和延迟期SIR有潜力作为鉴别肿块型慢性胰腺炎与胰腺导管腺癌的影像生物标志物。
研究设计与样本
- 回顾性研究纳入170例经根治性胰腺手术且标本病理确诊的受试者,其中肿块型慢性胰腺炎34例、胰腺导管腺癌136例,按性别、年龄和手术时间1:4匹配。
诊断标准与关键数值
- 胰腺导管腺癌组T1 SIR敏感度61.8%、特异度66.2%、AUC 0.620;动脉期SIR敏感度61.8%、特异度68.4%、AUC 0.659;门静脉期SIR敏感度70.6%、特异度59.6%、AUC 0.670;延迟期SIR敏感度73.5%、特异度55.9%、AUC 0.668。
临床应用与阅片要点
- 计算病灶信号强度与椎旁肌信号强度的比值(SIR),可辅助鉴别肿块型慢性胰腺炎与胰腺导管腺癌。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the utility of signal intensity ratio (SIR) in distinguishing between mass-forming chronic pancreatitis (MFCP) and pancreatic ductal adenocarcinoma (PDAC), thereby reducing unnecessary pancreatectomies or delayed diagnosis brought by misdiagnosis.
MATERIALS AND METHODS: This retrospective study included 170 participants (34 with MFCP and 136 with PDAC) who underwent radical pancreatic surgery and were diagnosed via specimen pathology. The study group was carefully selected with a 1:4 ratio matching for sex, age, and operation time between two entities. T1 SIR, T2 SIR, arterial phase (AP) SIR, portal venous phase (VP) SIR, delay phase (DP) SIR, DWI0-50 SIR, and DWI500-1000 SIR, were calculated by dividing the signal intensity of lesions by that of the paraspinal muscle, serving as a reference organ. Intraclass Correlation Coefficient (ICC) was estimated to evaluate the intraobserver and interobserver reliability. Wilcoxon tests were employed for univariate analysis, and receiver operating characteristic (ROC) curves were generated to determine optimal cutoff points and AUC values for selected predictors. A tenfold cross-validation method was applied to validate the robustness of the results.
RESULTS: The ICC demonstrated excellent correlation for both intraobserver and interobserver(ICCs > 0.8). T1 SIR, AP SIR, VP SIR, and DP SIR were significantly lower in the PDAC group compared to the MFCP group, and exhibited good independent predictive properties with the sensitivities of 61.8, 61.8, 70.6, and 73.5%, specificities of 66.2, 68.4, 59.6, and 55.9%, and AUCs of 0.620, 0.659, 0.670, and 0.668, respectively, hovering around 0.7. The tenfold cross-validation confirmed the reliability and robustness of our findings, with consistent AUC, sensitivity, specificity, and 95% confidence intervals over 1000 iterations.
CONCLUSION: T1 SIR, AP SIR, VP SIR, and DP SIR show promise as potential imaging biomarkers for distinguishing between MFCP and PDAC.
引用
- Li Y, Zheng C, Zhang Y, et al. Enhancing preoperative diagnosis of pancreatic ductal adenocarcinoma and mass-forming chronic pancreatitis: a study on normalized conventional MR imaging parameters. Abdom Radiol (NY). 2024. PMID: 39488674. doi:10.1007/s00261-024-04652-7