文献速递外周血管介入腹部USDSA

通畅的经颈静脉肝内门体分流术中的多普勒流速:10 mm与8 mm分流管的对比分析

Doppler velocities in patent transjugular intrahepatic portosystemic shunts: an analysis of 10 mm vs. 8 mm shunts.
PubMed 文献 · Abdom Radiol (NY) · 2024-11-18

该回顾性队列研究分析了2017至2022年间69例经静脉造影证实通畅的TIPS/DIPS患者的介入性多普勒超声,比较8 mm(n=41)与10 mm(n=28)支架的流速。结果显示支架中段和肝静脉端流速在8 mm支架中显著高于10 mm支架,而门静脉端和门静脉主干流速无显著差异。结论认为通畅TIPS/DIPS的正常多普勒流速因分流管直径而异,提示需针对不同口径支架制定特异性的多普勒筛查阈值。

要点

  • 8 mm支架中段平均流速184.7 cm/s,显著高于10 mm支架的148.9 cm/s(p=0.03)。
  • 8 mm支架肝静脉端平均流速172.4 cm/s,显著高于10 mm支架的141.3 cm/s(p=0.02)。
  • 多数8 mm支架峰值流速位于支架中段,多数10 mm支架峰值流速位于门静脉端。

核心结论

  • 通畅TIPS/DIPS内的正常多普勒流速因分流管直径而异,提示评估不同口径支架时需采用特异性的多普勒筛查阈值。

研究设计与样本

  • 回顾性分析2017至2022年一家大型三级医院TIPS/DIPS受者队列,共69例经静脉造影证实通畅且有多普勒超声资料的患者(8 mm组n=41,男性70.7%,平均年龄57.5岁,范围36-75岁;10 mm组n=28,男性50%,平均年龄50.2岁,范围24-74岁)。

关键影像表现/征象

  • 8 mm支架中段平均多普勒流速184.7 cm/s,10 mm支架为148.9 cm/s。
  • 8 mm支架肝静脉端平均多普勒流速172.4 cm/s,10 mm支架为141.3 cm/s。
  • 8 mm支架门静脉端平均多普勒流速140.7 cm/s,10 mm支架为146.8 cm/s。
  • 8 mm支架门静脉主干平均多普勒流速46.8 cm/s,10 mm支架为53.0 cm/s。
  • 多数通畅8 mm支架(n=22)峰值流速位于支架中段,多数10 mm支架(n=12)峰值流速位于门静脉端。

诊断标准与关键数值

  • 支架中段平均流速8 mm组184.7 cm/s vs 10 mm组148.9 cm/s,差异显著(p=0.03,95%CI 4.1-67.5)。
  • 肝静脉端平均流速8 mm组172.4 cm/s vs 10 mm组141.3 cm/s,差异显著(p=0.02,95%CI 5.2-57.0)。
  • 门静脉端平均流速8 mm组140.7 cm/s vs 10 mm组146.8 cm/s,无显著差异(p=0.77,95%CI -34.6-46.8)。
  • 门静脉主干平均流速8 mm组46.8 cm/s vs 10 mm组53.0 cm/s,无显著差异(p=0.29,95%CI -5.4-17.9)。

临床应用与阅片要点

  • 评估通畅TIPS/DIPS时,需注意支架口径对多普勒流速的影响,8 mm支架中段和肝静脉端流速通常高于10 mm支架。
  • 8 mm支架峰值流速多位于支架中段,10 mm支架峰值流速多位于门静脉端,阅片时应关注相应位置。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine if ultrasound Doppler velocities within transjugular portosystemic shunts/direct intrahepatic portosystemic shunts (TIPS/DIPS) differ based on the stent diameter (8 mm vs. 10 mm) and report typical flow velocities at defined locations along the stent in patients with a patent TIPS/DIPS on venography.

METHODS: This study retrospectively analyzed a cohort of TIPS/DIPS recipients at a large tertiary care hospital from 2017 to 2022. Sixty-nine patient-entries with patent TIPS/DIPS venograms and available intervening Doppler US were identified (8 mm n = 41; men: 70.7%, mean age: 57.5 years [range: 36-75 years]; 10-mm n = 28; men: 50%, mean age: 50.2 years [range: 24-74 years]).

RESULTS: The mean Doppler velocities were significantly different at the mid-stent (184.7 cm/s in 8 mm stents and 148.9 cm/s in 10 mm stents; p = 0.03, 95% CI 4.1-67.5) and hepatic-venous-end of the TIPS/DIPS (172.4 cm/s in 8 mm stents and 141.3 cm/s in 10 mm stents; p = 0.02, 95% CI 5.2-57.0). The mean Doppler velocities were not significantly different at the portal vein end of the TIPS (140.7 cm/s in 8 mm stents and 146.8 cm/s in 10 mm stents; p = 0.77, 95% CI - 34.6-46.8) or in the main portal vein (46.8 cm/s in 8 mm stents and 53.0 cm/s in 10 mm stents; p = 0.29, 95% CI - 5.4-17.9). Peak velocities occurred at the mid-TIPS location for the majority of patent 8 mm TIPS (n = 22) and at the portal-end of TIPS for the majority of 10 mm TIPS (n = 12).

CONCLUSION: Normal Doppler velocities within TIPS/DIPS differ depending on the shunt diameter. These findings demonstrate a need for specific Doppler screening thresholds in assessing TIPS/DIPS stents of differing calibers.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Mitchell M, Hegde K, Som A, et al. Doppler velocities in patent transjugular intrahepatic portosystemic shunts: an analysis of 10 mm vs. 8 mm shunts. Abdom Radiol (NY). 2024. PMID: 39551838. doi:10.1007/s00261-024-04682-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。