采用双源双能量CT定量参数评估肝硬化患者高危胃食管静脉曲张
前瞻性纳入98例连续患者行腹部三期对比增强双源双能量CT检查,最终57例纳入分析,以胃镜为参考标准分为需治疗静脉曲张组与非需治疗组。门静脉期肝脏标准化碘浓度、肝脏碘洗脱率和脾脏体积在两组间差异有统计学意义,基于二元logistic回归构建的混合CT模型预测需治疗静脉曲张的ROC曲线下面积最高。结论认为双源双能量CT在评估肝脏血流动力学和诊断需治疗静脉曲张方面有附加临床价值。
要点
- 门静脉期肝脏标准化碘浓度、肝脏碘洗脱率和脾脏体积在需治疗与非需治疗静脉曲张组间差异有统计学意义。
- 基于二元logistic回归构建的混合CT模型预测需治疗静脉曲张的ROC曲线下面积最高。
- 双源双能量CT定量参数可为肝硬化患者肝脏血流动力学评估和需治疗静脉曲张诊断提供附加信息。
核心结论
- 双源双能量CT在评估肝硬化患者肝脏血流动力学和诊断需治疗静脉曲张方面具有附加临床价值。
研究设计与样本
- 前瞻性研究,连续收集98例患者,最终57例纳入分析,所有患者行腹部三期对比增强双源双能量CT检查,以胃镜为参考标准分为需治疗静脉曲张组和非需治疗组。
关键影像表现/征象
- 记录肝脏实质、脾脏实质和主动脉在不同期的碘浓度和标准化碘浓度,并计算动脉碘分数、碘洗脱率和细胞外容积。
- 比较需治疗组与非需治疗组的临床特征、传统CT特征和双源双能量CT定量参数。
诊断标准与关键数值
- 单因素分析显示门静脉期肝脏标准化碘浓度、肝脏碘洗脱率和脾脏体积在需治疗组与非需治疗组间差异有统计学意义(p < 0.05)。
- 门静脉期肝脏标准化碘浓度、肝脏碘洗脱率、脾脏体积和混合CT模型预测肝硬化患者需治疗静脉曲张的ROC曲线均有统计学意义(p < 0.05)。
- 混合CT模型的ROC曲线下面积最高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the clinical value of dual-source dual-energy CT (dsDECT) quantitative parameters in evaluating hemodynamics and predicting high-risk gastroesophageal varices in cirrhotic patients.
METHODS: 98 consecutive patients were collected in this prospectively study and all patients underwent an abdominal triple-phase contrasted-enhanced examination with dsDECT. Iodine concentration (IC) and normalized iodine concentration (NIC) of the liver parenchyma, spleen parenchyma and aorta at different phases were recorded, and arterial iodine fraction (AIF), iodine washout rate (IWR), and extracellular volume (ECV) were calculated. Using upper gastrointestinal endoscopy as the reference standard, patients who met the inclusion and exclusion criteria were divided into groups with varices need treatment (VNT) and non-VNT. The clinical characteristics, traditional CT features and quantitative dsDECT parameters were compared between the VNT group and the non-VNT group using univariate analysis. The binary logistics analysis was used to build a model for diagnosing VNT. The receiver operating characteristic (ROC) curve was used for analysis and the DeLong test was used to compare different ROC curves.
RESULTS: Finally, 57 patients were included in this study. Univariate analysis showed statistically significant differences in NIC of the liver at the portal venous phase (NIC-LPVP), IWR of the liver (IWR-L) and spleen volume between the VNT group and the non-VNT group (p < 0.05). The mixed-CT model was built by binary logistics analysis. The ROC curves of NIC-LPVP, IWR-L, spleen volume and the mixed-CT model were statistically significant (p < 0.05) for predicting VNT in cirrhotic patients, among which the area under the ROC curve of the mixed-CT model was the highest.
CONCLUSION: Dual-source dual-energy CT has added clinical value in evaluating hepatic hemodynamics and diagnosing VNT in patients with liver cirrhosis.
引用
- Qiu Q, Ai Y, Pan Y, et al. Assessment of high-risk gastroesophageal varices in cirrhotic patients using quantitative parameters from dual-source dual-energy CT. Abdom Radiol (NY). 2024. PMID: 39542947. doi:10.1007/s00261-024-04666-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。