文献速递腹部US

Fly-Thru技术在胆道梗阻性疾病诊断中的临床应用:可行性、可重复性与诊断价值

Clinical application of fly-thru in diagnosis of biliary obstructive diseases: feasibility, reproducibility, and diagnostic value.
PubMed 文献 · Abdom Radiol (NY) · 2024-11-08

单中心前瞻性研究纳入100例胆道梗阻患者,评估三维Fly-Thru重建的可行性、可重复性及诊断价值;3D-FT判断梗阻程度不劣于PTC,与2D-US联合可显著提高诊断信心与准确率,尤其对经验较少的医师。

要点

  • 3D-FT图像均成功重建,75%与66%被两位医师评为清晰且对诊断高度有用。
  • 3D-FT判断胆道梗阻程度不劣于PTC(p=0.101)。
  • 2D-US联合3D-FT可显著提高诊断信心与准确率,尤其对经验较少者。

核心结论

  • 3D-FT用于胆道梗阻性疾病诊断被认为是可行且可重复的,具有满意的诊断价值和临床意义。

研究设计与样本

  • 单中心前瞻性研究,2013年1月至2023年1月连续纳入100例胆道梗阻患者(平均年龄59.6±13.2岁,男性52例),均行腹部超声与FT检查,以超声引导下经皮肝穿刺胆道造影(PTC)为对照。
  • 利用FT容积数据重建3D-FT图像,由两名放射科医师独立主观评估图像质量。

关键影像表现/征象

  • 良性病变与恶性肿瘤在2D-US和3D-FT图像上表现不同。
  • 3D-FT图像全部成功重建,多数图像被评为清晰且对诊断高度有用,两名医师间一致性良好。

诊断标准与关键数值

  • 3D-FT判断胆道梗阻程度与PTC比较p=0.101,敏感度90.5%、特异度26.7%、阳性似然比1.23、阴性似然比0.36、阳性预测值77.6%、阳性预测值50.0%(原文两处均写作阳性预测值,按上下文其一应为阴性预测值)。
  • 图像质量主观评估两名医师评分为清晰且高度有用的比例分别为75%和66%,一致性Kappa=0.653。

临床应用与阅片要点

  • 阅片时可结合2D-US与3D-FT评估胆道梗阻,联合应用可提高诊断信心与准确率,对经验较少的放射科医师帮助更明显。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the feasibility, reproducibility, and diagnostic value in biliary obstructive diseases using Fly-Thru (FT) technique.

METHODS: In this single-center prospective study, patients with biliary obstruction who underwent both abdominal ultrasound and FT examinations were recruited between January 2013 and January 2023. 3D FT images (3D-FT) were reconstructed with FT volumetric data. Image quality was subjectively assessed by two radiologists independently. 3D-FT was used to determine the degree of biliary obstruction and compared with ultrasound-guided percutaneous transhepatic cholangiography (PTC). Diagnostic confidence level, diagnostic accuracy and diagnostic duration of the two radiologists using 2D-ultrasound (2D-US) alone and 2D-US combined with 3D-FT were recorded respectively and compared.

RESULTS: 100 consecutive patients were enrolled (mean age: 59.6 ± 13.2 years; 52 men). All 3D-FT images were successfully reconstructed and most (75% and 66%) 3D-FT images were considered clear and highly useful for diagnosis with a good agreement (Kappa = 0.653). Benign lesions and malignancies presented differently in both 2D-US and 3D-FT imaging. 3D-FT was not inferior to PTC in determining the degree of biliary obstruction (p = 0.101), with the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, positive predictive value, and positive predictive value as 90.5%, 26.7%, 1.23, 0.36, 77.6%, 50.0% respectively. Combined with 2D-US, 3D-FT significantly increased the diagnostic confidence level and diagnostic accuracy of biliary obstructive diseases (all p < 0.01), especially for radiologists with less experience.

CONCLUSION: Application of 3D-FT in diagnosis of biliary obstructive diseases was considered feasible and reproducible, with satisfactory diagnostic value and clinical importance.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Huang T, Yang Z, Wang X, et al. Clinical application of fly-thru in diagnosis of biliary obstructive diseases: feasibility, reproducibility, and diagnostic value. Abdom Radiol (NY). 2024. PMID: 39514100. doi:10.1007/s00261-024-04672-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。