单中心回顾性研究利用2010年1月1日至2022年10月23日的灰阶超声图像,以MRI质子密度脂肪分数为参考标准,开发深度学习多实例程序区分正常与脂肪肝及轻中度与重度脂肪肝。S0 vs S1/2/3模型AUC 81.3%,S0/1 vs S2/3模型AUC 95.9%,多分类模型对S2/3敏感度87.5%。

要点

  • 以MRI-PDFF为参考,深度学习模型从标准灰阶超声区分正常与脂肪肝的AUC为81.3%。
  • 区分正常/轻度与中重度脂肪肝的AUC达95.9%,特异度96.9%。
  • 多分类模型对S2/3敏感度87.5%、特异度96.9%,对S0敏感度71.4%。

核心结论

  • 深度学习程序从标准超声图像检测和分类肝脂肪变性具有高敏感度和准确度。

研究设计与样本

  • 单中心回顾性研究,纳入403例患者403次灰阶超声检查,以MRI-PDFF为参考标准,数据集分为322例训练/验证集和81例盲法留出测试集。

诊断标准与关键数值

  • S0定义为MRI-PDFF<5%,S1为5-17.4%,S2为>17.4%-22.1%,S3为>22.1%;S0 vs S1/2/3模型AUC 81.3%(95%CI 72.1-90.5)、敏感度81.1%(70.6-91.6)、特异度71.4%(54.7-88.2)、平衡准确度76.3%(66.4-86.2);S0/1 vs S2/3模型AUC 95.9%(89-100)、敏感度87.5%(71.3-100)、特异度96.9%(92.7-100)、平衡准确度92.2%(83.8-100);多分类模型敏感度S0 71.4%(54.7-88.2)、S1 67.6%(52.5-82.7)、S2/3 87.5%(71.3-100),特异度S0 81.1%(70.6-91.6)、S1 77.3%(64.9-89.7)、S2/3 96.9%(92.7-100)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Early detection and monitoring of hepatic steatosis can help establish appropriate preventative measures against progression to more advanced disease. We aimed to develop a deep learning (DL) program for classification of hepatic steatosis from standard-of-care grayscale ultrasound (US) images.

METHODS: In this single-center retrospective study, we utilized grayscale US images from January 1, 2010, to October 23, 2022, labeled with magnetic resonance imaging (MRI) proton density fat fraction (MRI-PDFF) to develop a DL multi-instance program for differentiating normal (S0) from steatotic liver (S1/2/3) and normal/mild steatosis (S0/1) from moderate/severe steatosis (S2/3). Diagnostic performances were assessed with area under the receiver operating characteristic curves (AUC), sensitivity, specificity and balanced accuracy with 95% confidence interval (CI).

RESULTS: A total of 403 patients with 403 US exams were included: 171 (42%) were normal (S0: MRI-PDFF <5%), 154 (38%) had mild steatosis (S1: MRI-PDFF 5-17.4%), 29 (7%) had moderate steatosis (S2: MRI-PDFF >17.4%-22.1%) and 49 (12%) had severe steatosis (S3: MRI-PDFF >22.1%). The dataset was split to include 322 patients in train/validation and 81 patients in a holdout test set (kept blind). The S0 versus S1/2/3 model achieved 81.3% (95% CI 72.1-90.5) AUC, 81.1% (70.6-91.6) sensitivity, 71.4% (54.7-88.2) specificity and 76.3% (66.4-86.2) balanced accuracy. The S0/1 versus S2/3 model achieved 95.9% (89-100) AUC, 87.5% (71.3-100) sensitivity, 96.9% (92.7-100) specificity and 92.2% (83.8-100) balanced accuracy. A multi-class model achieved a sensitivity of 71.4% (54.7-88.2) for S0, 67.6% (52.5-82.7) for S1 and 87.5% (71.3-100) for S2/3; specificity for the same model was 81.1% (70.6-91.6) for S0, 77.3% (64.9-89.7) for S1 and 96.9% (92.7-100) for S2/3.

CONCLUSION: Our DL program offered high sensitivity and accuracy in detecting and categorizing hepatic steatosis from standard-of-care ultrasound.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Kaffas AE, Bhatraju KC, Vo-Phamhi JM, et al. Development of a Deep Learning Model for Classification of Hepatic Steatosis from Clinical Standard Ultrasound. Ultrasound Med Biol. 2024. PMID: 39537545. doi:10.1016/j.ultrasmedbio.2024.09.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。