使用扫描协议信息引导的深度学习方法进行无偏且可重复的肝脏MRI-PDFF估计
本研究提出VET-Net深度学习框架,从化学位移编码MRI估计质子密度脂肪分数(PDFF),并将回波时间作为辅助输入以适配不同扫描仪和回波时间设置。在单中心188例受试者数据及多中心体模数据集上,VET-Net的PDFF偏差为-0.55%,两个肝ROI的可重复性系数分别为1.71%和1.04%,优于传统深度学习方法,与图割法相当。
要点
- VET-Net在不同回波时间下右后叶和左叶PDFF可重复性系数分别为1.71%和1.04%。
- 多中心体模上VET-Net的PDFF偏差为-0.55%,小于图割法的0.93%。
- 省略回波时间辅助输入时,可重复性(1.94%和1.59%)和偏差(-2.04%)变差。
核心结论
- VET-Net利用不同硬件厂商和不同回波时间的CSE-MR图像提供无偏且精确的PDFF估计,优于传统深度学习方法。
研究设计与样本
- 单中心肝脏CSE-MRI数据集(188例受试者,4146个轴位层面),分为训练集150例、验证集18例和测试集20例,测试受试者采用不同回波时间的多种协议扫描;另使用开源多中心多厂商脂水体模数据集评估PDFF偏差;参考方法为基于图割的方法。
诊断标准与关键数值
- VET-Net在不同回波时间下右后叶和左肝叶的PDFF可重复性系数分别为1.71%和1.04%,图割法分别为1.71%和0.86%;多中心体模数据集上VET-Net的PDFF偏差为-0.55%,图割法为0.93%;不考虑辅助回波时间输入时,可重复性为1.94%和1.59%,偏差为-2.04%。
临床应用与阅片要点
- VET-Net可在不同MR扫描仪和扫描协议下提供高效且无偏的PDFF估计,从而可扩展基于MRI的肝脏脂肪定量在评估肝脂肪变性中的应用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To estimate proton density fat fraction (PDFF) from chemical shift encoded (CSE) MR images using a deep learning (DL)-based method that is precise and robust to different MR scanners and acquisition echo times (TEs).
METHODS: Variable echo times neural network (VET-Net) is a two-stage framework that first estimates nonlinear variables of the CSE-MR signal model, to posteriorly estimate water/fat signal components using the least-squares method. VET-Net incorporates a vector with TEs as an auxiliary input, therefore enabling PDFF calculation with any TE setting. A single-site liver CSE-MRI dataset (188 subjects, 4146 axial slices) was considered, which was split into training (150 subjects), validation (18), and testing (20) subsets. Testing subjects were scanned using several protocols with different TEs, which we then used to measure the PDFF reproducibility coefficient (RDC) at two regions of interest (ROIs): the right posterior and left hepatic lobes. An open-source multi-site and multi-vendor fat-water phantom dataset was also used for PDFF bias assessment.
RESULTS: VET-Net showed RDCs of 1.71% and 1.04% on the right posterior and left hepatic lobes, respectively, across different TEs, which was comparable to a reference graph cuts-based method (RDCs = 1.71% and 0.86%). VET-Net also showed a smaller PDFF bias (-0.55%) than graph cuts (0.93%) when tested on a multi-site phantom dataset. Reproducibility (1.94% and 1.59%) and bias (-2.04%) were negatively affected when the auxiliary TE input was not considered.
CONCLUSION: VET-Net provided unbiased and precise PDFF estimations using CSE-MR images from different hardware vendors and different TEs, outperforming conventional DL approaches.
KEY POINTS: Question Reproducibility of liver PDFF DL-based approaches on different scan protocols or manufacturers is not validated. Findings VET-Net showed a PDFF bias of -0.55% on a multi-site phantom dataset, and RDCs of 1.71% and 1.04% at two liver ROIs. Clinical relevance VET-Net provides efficient, in terms of scan and processing times, and unbiased PDFF estimations across different MR scanners and scan protocols, and therefore it can be leveraged to expand the use of MRI-based liver fat quantification to assess hepatic steatosis.
引用
- Meneses JP, Qadir A, Surendran N, et al. Unbiased and reproducible liver MRI-PDFF estimation using a scan protocol-informed deep learning method. Eur Radiol. 2024. PMID: 39500799. doi:10.1007/s00330-024-11164-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。