主动脉旁腹膜后病变经皮空芯针活检:大小和位置对CT引导活检诊断准确性的影响及超声引导的可行性
单机构回顾性研究纳入317例连续患者共345次主动脉旁腹膜后病变空芯针活检,CT引导332次、超声引导13次;总体敏感度96.7%、特异度100%、准确率97%,病变≤15 mm与>15 mm准确率相似(98.4% vs 96.9%),大出血发生率0.6%。
要点
- CT引导空芯针活检诊断主动脉旁腹膜后病变敏感度96.7%、特异度100%、准确率97%。
- 病变≤15 mm与>15 mm的CT引导活检准确率相似(98.4% vs 96.9%)。
- 主主动脉腔静脉间/腔静脉前病变可采用经腔静脉、经椎弓根或经椎间盘等替代CT引导入路。
核心结论
- CT引导空芯针活检对各位置病变均显示高诊断准确率,尤其采用标准后路椎旁入路时;对腔静脉前或主主动脉腔静脉间等困难病变,替代CT引导后路或超声引导前路可能有助于克服解剖限制并扩大经皮活检选择。
研究设计与样本
- 单机构回顾性研究,纳入317例连续患者共345次活检,使用18G切割针在CT或超声引导下进行,以活检和随访结果计算诊断准确率,并对CT引导活检假阴性预测因素行单因素分析。
诊断标准与关键数值
- 总体敏感度96.7%、特异度100%、准确率97%;病变≤15 mm准确率98.4%,>15 mm准确率96.9%;CT引导活检大出血发生率0.6%(2/332)。
临床应用与阅片要点
- 标准后路椎旁入路为常用方法;对腔静脉前或主主动脉腔静脉间病变,替代CT引导后路或超声引导前路可能有助于克服解剖限制并扩大经皮活检选择。
局限性
- 单机构回顾性研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the safety and efficacy of computed tomography (CT)-guided core needle biopsy (CNB) for para-aortic retroperitoneal lesions, identify factors affecting false-negative results, and explore the feasibility of alternative CT-guided and ultrasound-guided approaches for challenging anatomical regions.
MATERIALS AND METHODS: This single-institution retrospective study included 317 consecutive patients who underwent CNB for para-aortic retroperitoneal lesions. A total of 345 biopsies were performed using 18-gauge cutting needles under CT or ultrasound guidance. Diagnostic accuracy was calculated based on biopsy and follow-up results, and univariate analysis was performed to identify predictors of false-negative CT-guided biopsies.
RESULTS: Of the 332 CT-guided biopsies, 203 targeted lateral aortic lesions. The standard posterior paravertebral approach was commonly used; complex cases requiring alternative CT- or ultrasound-guided approaches involved pre-aortocaval or inter-aortocaval lesions. In CT-guided biopsies, 5 of the 30 lesions in these regions were accessed via trans-caval, trans-pedicle, or trans-disc approaches. All 13 ultrasound-guided biopsies were performed with anterior access except for 2 cases. Malignant lymphoma and nodal metastasis were the most common pathologic findings. Overall sensitivity, specificity, and accuracy were 96.7%, 100%, and 97%, respectively. Neither lesion size nor location predicted false-negative CT-guided biopsies with similar accuracy for lesions ≤15 mm (98.4%) and >15 mm (96.9%). Major bleeding occurred in two CT-guided biopsies (0.6%).
CONCLUSION: CT-guided CNB demonstrated high diagnostic accuracy across all lesion locations, particularly with the standard posterior paravertebral approach. For more challenging pre-aortocaval or inter-aortocaval lesions, alternative CT-guided posterior or ultrasound-guided anterior approaches may help overcome anatomical constrains and expand percutaneous options.
引用
- Itou C, Sone M, Arai Y, et al. Percutaneous core needle biopsy for para-aortic retroperitoneal lesions: impact of size and location on diagnostic accuracy of computed tomography-guided biopsy and feasibility of ultrasound guidance. Clin Radiol. 2024. PMID: 39532056. doi:10.1016/j.crad.2024.10.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。