一种用于先天性心脏病患者的新型非对比剂增强三维全心磁共振序列:REACT研究
本研究前瞻性纳入30例先天性心脏病患者,比较三维全心REACT序列与三维全心bSSFP序列对心脏结构和大血管的显示。REACT在肺静脉的信噪比和图像质量更优,而bSSFP在右心室、右肺动脉、右心房、主肺动脉和冠状动脉的图像质量更优;两种序列的横截面积测量无显著差异。
要点
- REACT序列在肺静脉的对比噪声比和图像质量优于bSSFP,适合肺静脉评估。
- bSSFP在右心室、右心房、主肺动脉及冠状动脉的图像质量更优。
- 两种序列横截面积测量无显著差异,可互换用于尺寸测量。
核心结论
- REACT序列在先天性心脏病患者中肺静脉的图像质量和对比噪声比更优,横截面积测量与bSSFP一致;bSSFP在心脏腔室和冠状动脉成像方面表现更好。
研究设计与样本
- 前瞻性研究,经机构审查委员会批准,纳入30例先天性心脏病患者,比较三维全心REACT序列与三维全心bSSFP序列。
关键影像表现/征象
- REACT在所有肺静脉的对比噪声比更高(所有P<0.05)。
- bSSFP在右心室(P<0.001)和右肺动脉(P=0.04)的对比噪声比更高。
- 图像质量方面,bSSFP在右心房和右心室(均P<0.001)、主肺动脉(P=0.02)及冠状动脉(左:P<0.001,右:P=0.01)更优。
- REACT在肺静脉的图像质量优于bSSFP(所有P<0.05)。
- 两种序列的横截面积测量无显著差异(所有P≥0.05)。
临床应用与阅片要点
- 评估肺静脉时,REACT序列可能提供更优的图像质量和对比噪声比。
- 评估右心室、右心房、主肺动脉和冠状动脉时,bSSFP序列的图像质量更优。
- 两种序列的横截面积测量一致,可根据解剖结构选择序列进行尺寸测量。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The three-dimensional balanced-steady-state-free-precession (3D bSSFP) whole-heart (WH) technique has long been used to depict cardiac morphology in congenital heart disease (CHD) but is prone to banding artifacts. The Relaxation Enhanced Angiography without Contrast and Triggering (REACT) sequence is an alternative method that is resistant to off-resonance effects.
OBJECTIVE: To evaluate cardiac structures and great vessels in CHD patients using 3D WH REACT sequence and compare it to 3D WH bSSFP sequence.
MATERIALS AND METHODS: This study was approved by the Institutional Review Board. Thirty CHD patients were prospectively enrolled. Contrast-to-noise ratio (CNR), image quality, and cross-sectional area (CSA) were analyzed. Categorical data were compared with a Wilcoxon signed-rank test and normally distributed variables with a t-test.
RESULTS: Thirty patients (16 females) participated in this study (median age 17, range 5 months to 52 years). REACT showed higher CNR in all pulmonary veins (all P<0.05), while 3D bSSFP had higher CNR in the right ventricle (P<0.001) and right pulmonary artery, (P=0.04). Image quality favored 3D bSSFP in the right atrium and ventricle (both P<0.001), main pulmonary artery (P=0.02), and coronary arteries (left: P<0.001, right: P=0.01). REACT outperformed 3D bSSFP for the pulmonary veins (all P<0.05) from image quality perspective. CSA measurements were not significantly different between REACT and 3D bSSFP (all P≥0.05).
CONCLUSION: The REACT method is associated with improved image quality and CNR for pulmonary veins, with CSA measurements concordant with 3D bSSFP in CHD patients, while bSSFP shows better performance for imaging cardiac chambers and coronary arteries.
引用
- Erdem S, Greil GF, Hussain MT, et al. A novel non-contrast agent-enhanced 3D whole-heart magnetic resonance sequence for congenital heart disease patients: the REACT Study. Pediatr Radiol. 2024. PMID: 39503860. doi:10.1007/s00247-024-06087-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。