人工智能辅助的冠状动脉CT血管成像斑块定量与血管内超声的诊断性能比较
本研究为单中心前瞻性注册研究的回顾性亚分析,纳入33例ST段抬高型心肌梗死患者共67支血管,比较AI-QCPA(HeartFlow)与IVUS定量斑块体积的一致性。AI-QCPA与IVUS在血管、管腔、总斑块、非钙化斑块和钙化斑块体积上均呈高度相关(ρ=0.87–0.97),Bland-Altman分析显示AI-QCPA低估总斑块体积(-9.4 mm3)和钙化斑块(-11.4 mm3),高估非钙化斑块(2.0 mm3)。
要点
- AI-QCPA与IVUS在血管和管腔体积上相关性很高(ρ分别为0.94和0.97)。
- AI-QCPA对总斑块、非钙化斑块和钙化斑块体积的ρ分别为0.92、0.91和0.87。
- 与IVUS相比,AI-QCPA低估总斑块体积(-9.4 mm3)和钙化斑块(-11.4 mm3),高估非钙化斑块(2.0 mm3)。
核心结论
- 用于CCTA的AI自动斑块定量工具在斑块体积定量和斑块特征描述方面与IVUS具有高度一致性。
研究设计与样本
- 单中心前瞻性注册研究的回顾性亚分析,纳入33例(平均年龄59.1岁±8.8[SD];27例[82%]男性,6例[18%]女性)ST段抬高型心肌梗死并接受罪犯血管直接经皮冠状动脉介入治疗的患者,共67支血管;非罪犯血管狭窄大于50%者于直接PCI后2至40天行CCTA、有创冠状动脉造影和非罪犯病变IVUS;采用Spearman秩相关和Bland-Altman分析比较AI-QCPA(HeartFlow)与IVUS的斑块体积。
诊断标准与关键数值
- AI-QCPA与IVUS血管体积的Spearman相关系数ρ=0.94。
- AI-QCPA与IVUS管腔体积的Spearman相关系数ρ=0.97。
- AI-QCPA与IVUS总斑块体积的Spearman相关系数ρ=0.92。
- AI-QCPA与IVUS非钙化斑块体积的Spearman相关系数ρ=0.91。
- AI-QCPA与IVUS钙化斑块体积的Spearman相关系数ρ=0.87。
临床应用与阅片要点
- Bland-Altman分析显示AI-QCPA较IVUS低估总斑块体积(-9.4 mm3)。
- Bland-Altman分析显示AI-QCPA较IVUS低估钙化斑块体积(-11.4 mm3)。
- Bland-Altman分析显示AI-QCPA较IVUS高估非钙化斑块体积(2.0 mm3)。
局限性
- 本文为单中心前瞻性注册研究的回顾性亚分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To assess the diagnostic performance of a coronary CT angiography (CCTA) artificial intelligence (AI)-enabled tool (AI-QCPA; HeartFlow) to quantify plaque volume, as compared with intravascular US (IVUS). Materials and Methods A retrospective subanalysis of a single-center prospective registry study was conducted in participants with ST-elevation myocardial infarction treated with primary percutaneous coronary intervention of the culprit vessel. Participants with greater than 50% stenosis in nonculprit vessels underwent CCTA, invasive coronary angiography, and IVUS of nonculprit lesion(s) between 2 and 40 days after primary percutaneous coronary intervention. Comparisons of plaque volumes obtained using AI-QCPA (HeartFlow) and IVUS were assessed using Spearman rank correlation (ρ) and Bland-Altman analysis. Results Thirty-three participants (mean age, 59.1 years ± 8.8 [SD]; 27 [82%] male and six [18%] female participants) and 67 vessels were included for analysis. There was strong agreement between AI-QCPA and IVUS in vessel (ρ = 0.94) and lumen volumes (ρ = 0.97). High agreement between AI-QCPA and IVUS was also found for total plaque volume (ρ = 0.92), noncalcified plaque (ρ = 0.91), and calcified plaque (ρ = 0.87). Bland-Altman analysis demonstrated AI-QCPA underestimated total plaque volume (-9.4 mm3) and calcified plaque (-11.4 mm3) and overestimated for noncalcified plaque (2.0 mm3) when compared with IVUS. Conclusion An AI-enabled automated plaque quantification tool for CCTA had high agreement with IVUS for quantifying plaque volume and characterizing plaque. Keywords: Coronary Plaque, Intravascular US, Coronary CT Angiography, Artificial Intelligence Supplemental material is available for this article. ClinicalTrials.gov registration no. NCT02926755 © RSNA, 2024.
引用
- Ihdayhid AR, Tzimas G, Peterson K, et al. Diagnostic Performance of AI-enabled Plaque Quantification from Coronary CT Angiography Compared with Intravascular Ultrasound. Radiol Cardiothorac Imaging. 2024. PMID: 39540820. doi:10.1148/ryct.230312
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。