本研究纳入18例既往3T MRI证实心肌纤维化的患者,前瞻性进行5T心肌LGE MRI随访,使用相同对比剂剂量。结果显示5T与3T的主观图像质量评分和LGE定量百分比无显著差异,但5T的信噪比和对比噪声比均优于3T。

要点

  • 5T与3T心肌LGE的主观图像质量评分中位数均为4.0,差异无统计学意义(P=.45)。
  • 5T信噪比高于3T(183.7 vs 125.8,P=.002),正常心肌和心包脂肪的对比噪声比亦更高(均P<.001)。
  • 5T与3T的LGE定量百分比无显著差异(中位数11.8% vs 12.6%,P=.81)。

核心结论

  • 5T心肌LGE MRI可行,与3T相比主观图像质量和心肌纤维化定量无差异证据,且相同对比剂剂量下信噪比和对比噪声比改善。

研究设计与样本

  • 前瞻性自身对照研究,纳入2023年1月至7月既往3T MRI证实心肌纤维化的连续患者18例,于2023年8月至11月进行5T随访成像,使用相同对比剂剂量。

关键影像表现/征象

  • 5T信噪比中位数183.7(IQR 147.2-255.9)高于3T的125.8(IQR 108.2-171.6),P=.002。
  • 5T正常心肌对比噪声比中位数50.8(IQR 35.4-67.9)高于3T的16.5(IQR 11.3-24.6),P<.001。
  • 5T心包脂肪对比噪声比中位数21.4(IQR 7.1-29.3)高于3T的-5.0(IQR -16.4至-2.3),P<.001。
  • 5T与3T图像质量Likert评分中位数均为4.0(IQR分别为3.0-4.4和3.0-4.2),P=.45。

诊断标准与关键数值

  • 图像质量采用Likert量表评分,范围1-5分。
  • 5T与3T的LGE定量百分比中位数分别为11.8%(IQR 7.7%-20.5%)和12.6%(IQR 6.6%-20.4%),P=.81。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Cardiac MRI at 5 T has recently become available and potentially improves tissue contrast enhancement at gadolinium chelate-enhanced T1-weighted imaging. Purpose To evaluate the feasibility of 5-T myocardial late gadolinium enhancement (LGE) MRI in assessing myocardial fibrosis by comparing image quality and LGE quantification with reference-standard 3-T myocardial LGE MRI. Materials and Methods Consecutive patients with confirmed myocardial fibrosis on previous 3-T MRI scans between January 2023 and July 2023 prospectively underwent follow-up imaging from August 2023 to November 2023. Each participant underwent follow-up 5-T imaging using an identical dose of contrast agent. Radiologist scoring of image quality using a Likert scale (range, 1-5), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), contrast ratio, and semiautomatic quantitative LGE assessment were obtained and reported as medians and IQRs. Paired Wilcoxon signed rank tests were used to compare characteristics derived at 3-T and 5-T imaging. Results A total of 18 participants (mean age, 49 years ± 17 [SD]; nine male participants) were included, with a mean interval of 6.2 months ± 2.3 between undergoing 3-T and 5-T MRI. Median image quality scores were 4.0 (IQR, 3.0-4.2) at 3 T and 4.0 (IQR, 3.0-4.4) at 5 T (P = .45). SNR at 5 T was higher than at 3 T (183.7 [IQR, 147.2-255.9] vs 125.8 [IQR, 108.2-171.6], respectively; P = .002). Median CNR at 5 T was higher than at 3 T in normal myocardium (50.8 [IQR, 35.4-67.9] vs 16.5 [IQR, 11.3-24.6], respectively) and pericardial fat (21.4 [IQR, 7.1-29.3] vs -5.0 [IQR, -16.4 to -2.3], respectively) (both P < .001). There was no evidence of a difference in the percentage of LGE quantified between 5 T and 3 T (median, 11.8% [IQR, 7.7%-20.5%] vs 12.6% [IQR, 6.6%-20.4%], respectively; P = .81). Conclusion Myocardial LGE MRI at 5 T was found to be feasible, with no evidence of differences in subjective image quality and myocardial fibrosis quantification compared with 3-T myocardial LGE MRI. Furthermore, with use of identical contrast agent doses, SNRs and CNRs were improved at 5 T. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Czum in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Guo Y, Lin L, Zhao S, et al. Myocardial Fibrosis Assessment at 3-T versus 5-T Myocardial Late Gadolinium Enhancement MRI: Early Results. Radiology. 2024. PMID: 39530890. doi:10.1148/radiol.233424