明胶海绵针道栓塞降低CT引导经胸肺活检气胸发生率的系统评价与Meta分析
该系统评价与Meta分析检索截至2023年9月的文献,纳入6项研究比较CT引导肺活检中使用与不使用明胶海绵浆行针道栓塞的气胸发生率。汇总分析显示,针道栓塞组气胸风险降低59%(OR=0.41,95%CI=0.25-0.66,P=.01),需胸腔置管的严重气胸风险降低63%(OR=0.37,95%CI=0.20-0.69,P=.01)。作者结论认为明胶海绵针道栓塞对气胸及胸腔置管具有显著保护作用。
要点
- CT引导肺活检行明胶海绵针道栓塞可使气胸风险降低59%(OR=0.41,95%CI=0.25-0.66,P=.01)。
- 针道栓塞使需胸腔置管的严重气胸风险降低63%(OR=0.37,95%CI=0.20-0.69,P=.01)。
- 该系统评价纳入6项研究,检索截至2023年9月,采用ROBINS-I工具评估偏倚。
核心结论
- 使用明胶海绵行针道栓塞对接受CT引导肺活检的患者气胸及胸腔置管具有显著保护作用。
研究设计与样本
- 系统评价与Meta分析,检索SCOPUS、PubMed、Google Scholar和EMBASE截至2023年9月的原始研究,纳入6项研究,使用ROBINS-I工具评估偏倚,计算气胸及胸腔置管发生率的汇总OR并报告95%CI和预测区间(PI)。
诊断标准与关键数值
- 针道栓塞组对比未栓塞组气胸风险OR=0.41(95%CI=0.25-0.66,P=.01;PI=-1.694至0.094),风险降低59%。
- 针道栓塞组对比未栓塞组需胸腔置管的严重气胸OR=0.37(95%CI=0.20-0.69,P=.01;PI=-1.855至0.115),风险降低63%。
临床应用与阅片要点
- 作者结论认为明胶海绵针道栓塞可有效降低肺活检后气胸及胸腔置管风险。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Transthoracic CT-guided lung biopsy is associated with risk of pneumothorax, requiring chest tube placement at times. From available literature, we tried to compare the incidence rate of pneumothorax in cases undergoing CT-guided lung biopsy with versus without use of gelfoam slurry for tract occlusion.
METHODS: Databases like SCOPUS, PubMed, Google Scholar, and EMBASE were searched for original studies analysing the efficacy of gelfoam for needle tract embolization following CT-guided lung biopsy till September 2023. Bias in the selected studies was assessed using the Risk Of Bias In Non-randomized Studies of Interventions (ROBINS-I) tool. Pooled odds ratio of the effect of gelfoam slurry on the rate of pneumothorax and chest tube placement following CT-guided lung biopsy was calculated and represented with 95% confidence intervals (95% CI) and prediction interval (PI).
RESULTS: Pooled analysis of six studies revealed that patients undergoing needle tract embolization when compared to non-embolized patients had a significantly decreased risk of pneumothorax with odds reduced by 59% (OR = 0.41, 95% CI = 0.25-0.66, P = .01; PI = -1.694 to 0.094). Also, it led to a significant reduction in severe pneumothorax requiring chest tube placement with reduced odds by 63% (OR = 0.37, 95% CI = 0.20-0.69, P = .01; PI = -1.855 to 0.115).
CONCLUSION: Needle tract embolization using gelfoam has a significant protective effect against pneumothorax as well as chest tube insertion in patients undergoing CT-guided lung biopsy.
ADVANCES IN KNOWLEDGE: Gelfoam needle tract embolization can effectively reduce the risk of pneumothorax and chest tube requirement after lung biopsy.
PROSPERO REGISTRATION ID: CRD42024505788.
引用
- Singh P, Nayak MK, Singhal T, et al. Efficacy of needle tract embolization using gelfoam in reducing incidence of pneumothorax in CT-guided transthoracic lung biopsies: a systematic review and meta-analysis. Br J Radiol. 2025. PMID: 39607776. doi:10.1093/bjr/tqae228
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。