文献速递胸部MRCT

三维零回波时间(3D-ZTE)肺MRI与胸部CT在系统性硬化相关间质性肺病评估中的比较

Comparing three-dimensional zero echo time (3D-ZTE) lung MRI and chest CT in the evaluation of systemic sclerosis-related interstitial lung disease.
PubMed 文献 · Eur Radiol · 2024-11-26

这项前瞻性单中心研究纳入65例系统性硬化患者,在一周内完成CT、3D-ZTE肺MRI和肺功能检查,由三名独立阅片者视觉量化ILD范围。CT检出45例ILD,3D-ZTE MRI识别其中41例(91.1%),与CT评估ILD严重程度强相关(r=0.986,p<0.001),观察者间信度ICC为0.853–0.969。作者结论认为3D-ZTE肺MRI是评估SSc相关ILD的可靠无辐射替代方法,但在检测细网状影和粗糙度方面存在局限。

要点

  • 3D-ZTE MRI对CT检出的SSc相关ILD识别率为91.1%(41/45例)。
  • 3D-ZTE MRI与CT评估ILD严重程度强相关(r=0.986,p<0.001)。
  • 3D-ZTE MRI观察者间信度ICC为0.853–0.969,属优秀水平。

核心结论

  • 3D-ZTE肺MRI是评估SSc相关ILD的可靠无辐射替代方法,在评估总纤维化和磨玻璃影方面与胸部CT强相关,但在检测细网状影和粗糙度方面仍存在局限。

研究设计与样本

  • 前瞻性单中心研究,纳入65例系统性硬化患者,一周内完成CT、3D-ZTE肺MRI和肺功能检查(PFTs)。

关键影像表现/征象

  • ILD在CT上检出45例,3D-ZTE MRI识别其中41例(91.1%)。
  • ILD范围中位评分CT为5%、3D-ZTE MRI为6%。
  • 3D-ZTE MRI与CT评估ILD严重程度强相关(r=0.986,p<0.001)。
  • 3D-ZTE MRI观察者间信度ICC为0.853–0.969。
  • 3D-ZTE MRI上ILD范围与肺功能(尤其是FVC)呈显著负相关。

诊断标准与关键数值

  • 以薄层胸部CT为对照,3D-ZTE MRI对CT检出ILD的识别率为91.1%(41/45例)。
  • ILD严重程度相关性r=0.986(p<0.001),观察者间ICC为0.853–0.969。

临床应用与阅片要点

  • 3D-ZTE肺MRI可作为无辐射方法用于SSc相关ILD范围的纵向监测。
  • 评估时需注意3D-ZTE MRI在检测细网状影和粗糙度方面存在局限。

局限性

  • 原文指出3D-ZTE MRI在检测细网状影和粗糙度方面仍存在局限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Systemic sclerosis (SSc) is a chronic disease that can cause interstitial lung disease (ILD), a poor prognostic factor in SSc patients. Given the concerns over radiation exposure from repeated CT scans, there is a growing interest in exploring radiation-free imaging alternatives like MRI for ILD evaluation. The aim of this study is to assess the efficacy of three-dimensional zero echo time (3D-ZTE) MRI in assessing SSc-related ILD compared to the thin-slice chest CT.

METHODS: This prospective single-center study investigated 65 SSc patients. SSc patients underwent CT, 3D-ZTE lung MRI, and pulmonary function tests (PFTs) within a week. Three independent reviews visually quantified ILD extent on ZTE and CT imaging and the correlation of ILD extent with PFTs was analyzed. Statistical analyses were performed, including the intraclass correlation coefficient (ICC), Kruskal-Wallis tests, Bland-Altmann analysis, and correlation analyses between imaging results and PFTs.

RESULTS: ILD was detected in 45 patients via CT. 3D-ZTE MRI identified ILD in 41 (91.1%) of these cases, demonstrating a strong correlation with CT in assessing ILD severity (r = 0.986, p < 0.001). The median ILD extent scores were 5% for CT and 6% for 3D-ZTE MRI. Interobserver reliability for 3D-ZTE MRI was excellent, with ICC values ranging from 0.853 to 0.969. The analysis also revealed significant negative correlations between ILD extent on ZTE MRI and lung function, particularly FVC.

CONCLUSION: 3D-ZTE lung MRI is a reliable and radiation-free alternative to chest CT for evaluating SSc-related ILD, with a strong correlation in assessing total fibrosis and ground-glass opacities, though limitations remain in detecting fine reticulations and coarseness.

KEY POINTS: Question Can 3D-ZTE MRI replace thin-slice chest CT as a radiation-free method for assessing SSc-related ILD? Findings 3D-ZTE lung MRI showed an excellent agreement with thin-slice CT in evaluating ILD extent in SSc patients (r = 0.986, p < 0.001). Clinical relevance 3D-ZTE lung MRI provides a reliable, radiation-free alternative to CT for assessing ILD extent in SSc patients, ensuring safer longitudinal monitoring and management.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Ufuk F, Kurnaz B, Peker H, et al. Comparing three-dimensional zero echo time (3D-ZTE) lung MRI and chest CT in the evaluation of systemic sclerosis-related interstitial lung disease. Eur Radiol. 2024. PMID: 39592487. doi:10.1007/s00330-024-11216-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。