整合常规胸部CT的影像组学、骨形态学与Hounsfield单位评估骨密度状态的新方法
本研究回顾性分析120例一个月内接受常规胸部CT和双能X线吸收法检查的患者,从常规胸部CT分割胸椎并提取影像组学特征、骨形态学特征和HU值,用六种机器学习模型进行三分类。基于影像组学特征与骨形态学特征整合的多层感知机模型在正常骨密度、骨量减少和骨质疏松三类的AUC分别为0.981、0.896和0.927。结论认为该模型能有效区分不同骨密度状态。
要点
- 常规胸部CT可提取影像组学、骨形态学及HU值用于骨密度状态评估。
- 多层感知机模型整合影像组学与骨形态学特征三分类性能较高。
- 正常骨密度、骨量减少、骨质疏松的AUC分别为0.981、0.896、0.927。
核心结论
- 基于影像组学特征与骨形态学特征组合的多层感知机分类模型在三分类方式下能有效区分不同骨密度状态。
研究设计与样本
- 回顾性研究,纳入120例在一个月内接受常规胸部CT和双能X线吸收法检查的患者,从常规胸部CT图像分割整个胸椎椎体,采用GrowCut半自动分割法,提取影像组学特征、骨形态学特征和HU值,使用六种机器学习分类模型进行三分类,以双能X线吸收法为参考标准。
诊断标准与关键数值
- 分割一致性用Dice相似系数评估,观察者内为0.907 ± 0.034,观察者间为0.887 ± 0.048;经两步特征选择后选出21个影像组学特征;多层感知机模型基于影像组学特征与骨形态学特征整合,在三分类中正常骨密度组AUC为0.981(95%CI:0.937-0.997),骨量减少组AUC为0.896(95%CI:0.826-0.944),骨质疏松组AUC为0.927(95%CI:0.866-0.967)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The purpose of this study is the feasibility of using radiomics features, bone morphometry features (BM), and Hounsfield unit (HU) values obtained from routine chest computed tomography (CT) for assessing bone mineral density (BMD) status.
MATERIALS AND METHODS: This retrospective study analyzed 120 patients who underwent routine chest CT and dual-energy X-ray absorptiometry examinations within a month. Whole thoracic vertebral bodies from routine chest CT images were segmented using the GrowCut semi-automatic segmentation method, and radiomics features, BM features, and HU values were extracted. To assess the intra- and inter-observer variability of segmentation, the Dice similarity coefficient (DSC) was utilized. Feature selection was carried out using the intra-class correlation coefficient and the Boruta algorithm. Six machine learning classification models were employed for classification in a three-class manner. The models' performance was evaluated using the area under the receiver operator characteristics curve (AUC). Other evaluation parameters of the models were calculated, including overall accuracy, precision, and sensitivity.
RESULTS: The DSC values showed high similarity by achieving 0.907 ± 0.034 and 0.887 ± 0.048 for intra- and inter-observer segmentation agreement, respectively. After a two-stepwise feature selection, 21 radiomics features were selected. Different combinations of these radiomics features with five BM features and HU values were applied to six classification models for evaluating BMD. The multilayer perceptron (MLP) model based on integration of radiomics features and BM features in a three-class classification approach achieved higher performance compared to other models with an AUC of 0.981 (95% confidence interval (CI): 0.937-0.997) in normal BMD class, an AUC of 0.896 (95% CI: 0.826-0.944) in osteopenia class, and an AUC of 0.927 (95% CI: 0.866-0.967) in osteoporosis class.
CONCLUSION: Using the MLP classification model based on a combination of radiomics features and BM features in a three-class classification approach can effectively distinguish different BMD conditions.
引用
- Mohammadi-Sadr M, Cheki M, Moslehi M, et al. A Novel Approach Based on Integrating Radiomics, Bone Morphometry and Hounsfield Unit-Derived From Routine Chest CT for Bone Mineral Density Assessment. Acad Radiol. 2024. PMID: 39562197. doi:10.1016/j.acra.2024.10.049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。