文献速递胸部MR

肺部129Xe MRI:卷积神经网络配准与分割生成通气缺陷百分比的多中心验证

Pulmonary 129Xe MRI: CNN Registration and Segmentation to Generate Ventilation Defect Percent with Multi-center Validation.
PubMed 文献 · Acad Radiol · 2024-11-23

研究开发并外部验证了自动深度学习流程(CNN配准与分割),用于量化肺部129Xe MRI的通气缺陷百分比(VDP)。在Site1的205例受试者中训练测试,在Site2和Site3的71例受试者中外部验证,CNN与半自动方法的配准误差低、分割gDSC高、VDP高度相关,各站点偏倚均较小。

要点

  • CNN自动流程可替代半自动方法量化129Xe MRI通气缺陷百分比,减少观察者交互时间。
  • 外部验证显示CNN与半自动VDP在三个站点均高度相关,偏倚在-0.5%至-0.9%之间。
  • 胸部腔和通气分割的gDSC分别为0.92和0.88,空间对应性好。

核心结论

  • 外部验证的CNN配准/分割模型与半自动方法高度一致、误差低,CNN与半自动的配准、胸部腔容积和通气容积分割高度相关且gDSC高。

研究设计与样本

  • 研究论文;使用Site1的205例参与者(健康志愿者、哮喘、COPD、长COVID;平均年龄54±16岁;119例女性)的1H和129Xe MRI数据训练和测试CNN分割与配准流程,Site2和Site3共71例参与者提供外部验证;以半自动方法为参考。

诊断标准与关键数值

  • 配准误差:CNN与半自动1H和129Xe配准一致,旋转MAE=0.3°(R2=0.95)、缩放MAE=1.1%(R2=0.79)、x/y平移MAE=0.2/0.5px(R2=0.96/0.95),均p<.001。
  • 分割一致性:胸部腔和通气分割的gDSC分别为0.92和0.88。
  • VDP相关性:Site1 R2/ρ=.97/.95、偏倚=-0.5%;Site2 R2/ρ=.85/.93、偏倚=-0.9%;Site3 R2/ρ=.95/.89、偏倚=-0.8%,均p<.001。

临床应用与阅片要点

  • CNN自动流程可用于量化肺部129Xe MRI的VDP,与半自动方法结果高度一致,有望减少观察者交互时间并支持多中心应用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Hyperpolarized 129Xe MRI quantifies ventilation-defect-percent (VDP), the ratio of 129Xe signal-void to the anatomic 1H MRI thoracic-cavity-volume. VDP is associated with airway inflammation and disease control and serves as a treatable trait in therapy studies. Semi-automated VDP pipelines require time-intensive observer interactions. Current convolutional neural network (CNN) approaches for quantifying VDP lack external validation, which limits multicenter utilization. Our objective was to develop an automated and externally validated deep-learning pipeline to quantify pulmonary 129Xe MRI VDP.

MATERIALS AND METHODS: 1H and 129Xe MRI data from the primary site (Site1) were used to train and test a CNN segmentation and registration pipeline, while two independent sites (Site2 and Site3) provided external validation. Semi-automated and CNN-based registration error was measured using mean-absolute-error (MAE) while segmentation error was measured using generalized-Dice-similarity coefficient (gDSC). CNN and semi-automated VDP were compared using linear regression and Bland-Altman analysis.

RESULTS: Training/testing used data from 205 participants (healthy volunteers, asthma, COPD, long-COVID; mean age=54 ± 16y; 119 females) from Site1. External validation used data from 71 participants. CNN and semi-automated 1H and 129Xe registrations agreed (MAE=0.3°, R2 =0.95 rotation; 1.1%, R2 =0.79 scaling; 0.2/0.5px, R2 =0.96/0.95, x/y-translation; all p < .001). Thoracic-cavity and ventilation segmentations were also spatially corresponding (gDSC=0.92 and 0.88, respectively). CNN VDP correlated with semi-automated VDP (Site1 R2/ρ = .97/.95, bias=-0.5%; Site2 R2/ρ = .85/.93, bias=-0.9%; Site3 R2/ρ = .95/.89, bias=-0.8%, all p < .001).

CONCLUSION: An externally validated CNN registration/segmentation model demonstrated strong agreement with low error compared to the semi-automated method. CNN and semi-automated registrations, thoracic-cavity-volume and ventilation-volume segmentations were highly correlated with high gDSC for the datasets.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Mozaffaripour A, Matheson AM, Rahman O, et al. Pulmonary 129Xe MRI: CNN Registration and Segmentation to Generate Ventilation Defect Percent with Multi-center Validation. Acad Radiol. 2024. PMID: 39581785. doi:10.1016/j.acra.2024.10.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。