光子计数CT碘图诊断慢性肺血栓栓塞症:一项先导研究
本研究回顾性纳入83例因临床指征行光子计数探测器CT(PCD-CT)以排除慢性血栓栓塞性肺动脉高压(CTEPH)的受试者,两名盲法阅片者利用碘图及肺窗锐核重建评估灌注缺损并识别慢性肺血栓栓塞症。阅片者间一致性良好(Cohen κ=0.74),共识判读准确度0.88、敏感度0.94、特异度0.84,与多学科临床诊断一致性良好(Cohen κ=0.75),平均有效剂量1.3±0.76 mSv。
要点
- 碘图联合肺窗锐核重建诊断慢性肺血栓栓塞症准确度0.88、敏感度0.94、特异度0.84。
- 阅片者间一致性良好(Cohen κ=0.74),与多学科临床诊断一致性良好(Cohen κ=0.75)。
- 未漏诊以CTEPH为PH主要病因或CTED的病例,肺动脉高压患者最常被判为假阳性。
核心结论
- 使用PCD-CT扫描重建的碘图可在低辐射剂量下准确、敏感且特异地诊断慢性肺血栓栓塞症。
研究设计与样本
- 经机构审查委员会批准的回顾性研究,纳入83例(男性49.4%,年龄62.4±13.4岁;女性50.6%,年龄59.9±17.1岁)因临床指征行PCD-CT以排除CTEPH的受试者;两名盲法阅片者使用碘图及相应肺窗锐核CT重建评估灌注缺损,分歧经后续共识判读解决;临床诊断在多学科临床环境中复核;计算放射学评估与临床诊断的准确度、敏感度和特异度。
关键影像表现/征象
- 碘图及肺窗锐核重建用于评估肺实质灌注缺损并识别慢性肺血栓栓塞症(CTEPH、CTEPH重叠其他原因肺动脉高压、慢性血栓栓塞性疾病)。
诊断标准与关键数值
- 共识判读诊断慢性肺血栓栓塞症的准确度0.88、敏感度0.94、特异度0.84。
- 阅片者间一致性Cohen κ=0.74,与多学科临床诊断一致性Cohen κ=0.75。
- 83例中32例诊断为CTEPH、CTEPH重叠或CTED,35例为其他病理机制所致PH,10例无PH,6例既往急性肺栓塞已消退。
- 平均有效剂量(±标准差)为1.3(±0.76)mSv。
临床应用与阅片要点
- 两名盲法阅片者仅使用碘图及肺窗锐核重建、未获其他临床或影像信息进行评估,分歧经共识判读解决。
- 以CTEPH为PH主要病因或CTED的病例均未漏诊,肺动脉高压患者最常被判为假阳性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to evaluate the feasibility and efficacy of chronic pulmonary thromboembolism assessment using photon-counting detector computed tomography (PCD-CT) iodine maps of the lung parenchyma.
MATERIALS AND METHODS: This institutional review board-approved retrospective study included 83 subjects (49.4% male, aged 62.4 ± 13.4 years; 50.6% female, aged 59.9 ± 17.1 years) who underwent clinically indicated PCD-CT scan to rule out chronic thromboembolic pulmonary hypertension (CTEPH). Two blinded readers used iodine maps and corresponding sharp-kernel CT reconstructions in the lung window to evaluate perfusion defects and identify patients with chronic pulmonary thromboembolism (CTEPH, CTEPH overlap with other causes of pulmonary hypertension [PH], chronic thromboembolic disease [CTED]). No other clinical or imaging information was given. Discordance was resolved in a subsequent consensus read. The clinical diagnosis was reviewed in an interdisciplinary clinical setting. The accuracy, sensitivity, and specificity of radiologic evaluation and clinical diagnosis were calculated.
RESULTS: Of the 83 subjects included, 32 were diagnosed with CTEPH, CTEPH overlap, or CTED, 35 were diagnosed with PH caused by other pathologic mechanisms, 10 had no PH, and 6 had suffered previous acute pulmonary embolism, which resolved. The interreader agreement was good (Cohen κ = 0.74). The consensus reached high accuracy (0.88), sensitivity (0.94), and specificity (0.84), as well as good agreement with interdisciplinary clinical diagnosis (Cohen κ = 0.75). No cases with confirmed CTEPH as the primary cause of PH or CTED were missed. Patients with pulmonary arterial hypertension were most frequently rated false-positive. The mean effective dose (±standard deviation) was 1.3 (±0.76) mSv.
CONCLUSIONS: Accurate, sensitive, and specific diagnosis of pulmonary chronic thromboembolism at low radiation dose is possible using iodine maps reconstructed from PCD-CT scans.
引用
- Kerber B, Flohr T, Ulrich S, et al. Photon-Counting CT Iodine Maps for Diagnosing Chronic Pulmonary Thromboembolism: A Pilot Study. Invest Radiol. 2024. PMID: 39509343. doi:10.1097/RLI.0000000000001134
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。