文献速递胸部介入CT

CT引导下同轴肺活检:活检芯数与并发症的关系

CT-guided Coaxial Lung Biopsy: Number of Cores and Association with Complications.
PubMed 文献 · Radiology · 2024-01-01

这项回顾性研究纳入2012年11月至2023年8月在一家学术三级转诊医院连续接受经皮CT引导下同轴肺芯针活检的可疑原发性肺癌患者827例,分析活检芯数与术后并发症的关系。多变量分析显示,活检芯数与气胸、胸腔置管、病灶周围出血或咯血均无关联证据。

要点

  • 活检芯数中位数4个(范围1–12),与气胸、胸腔置管、病灶周围出血及咯血均无关联证据。
  • 气胸发生率20.7%,胸腔置管3.9%,病灶周围出血42.7%,咯血2.4%。
  • 为满足肿瘤基因组分析需要更多组织时,增加活检芯数未显示与并发症相关。

核心结论

  • 在可疑肺癌患者中,经皮CT引导下同轴肺芯针活检所获活检芯数与术后并发症之间无关联证据。

研究设计与样本

  • 回顾性研究,纳入2012年11月至2023年8月在一家学术三级转诊医院连续接受经皮CT引导下同轴肺芯针活检的可疑原发性肺癌患者827例,采用多变量logistic回归模型评估活检芯数是否为并发症的预测因素。

诊断标准与关键数值

  • 多变量分析显示活检芯数与各并发症均无关联证据:气胸(系数-0.02,P=.81)、胸腔置管(系数0.18,P=.26)、病灶周围出血(系数-0.03,P=.63)、咯血(系数-0.10,P=.60)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Percutaneous CT-guided lung core-needle biopsy is a frequently performed and generally safe procedure. However, with advances in the management of lung cancer, there is a need for a greater amount of tissue for tumor genomic profiling and characterization. Purpose To determine whether the number of core samples obtained with percutaneous CT-guided lung biopsy is associated with postprocedural complications. Materials and Methods This retrospective study included consecutive patients who underwent percutaneous CT-guided coaxial lung core-needle biopsy for suspected primary lung cancer between November 2012 and August 2023 at an academic tertiary referral hospital. Patient data from medical records were collected, including demographics, lesion size and distance from pleura, and number of obtained biopsy samples. Postprocedural complications of pneumothorax, chest tube placement, perilesional hemorrhage, and hemoptysis were recorded. Multivariable logistic regression models were used to assess whether the number of cores was a predictive factor for lung biopsy complications. Results A total of 827 patients (mean age, 70.9 years ± 9.6 [SD]; 474 [57.3%] female patients) were included. The median lesion size was 22 mm (IQR, 15-34 mm), with 517 of 827 (62.5%) patients diagnosed with lung adenocarcinoma. Pneumothorax was noted in 171 of 827 (20.7%) patients, with a chest tube placed in 32 of 827 (3.9%), perilesional hemorrhage in 353 of 827 (42.7%), and hemoptysis in 20 of 827 (2.4%) patients. The median number of samples obtained was four (range, one to 12). Multivariable analysis showed no evidence of an association between the number of core samples obtained and any complications: pneumothorax (coefficient, -0.02; P = .81), chest tube (coefficient, 0.18; P = .26), perilesional hemorrhage (coefficient, -0.03; P = .63), or hemoptysis (coefficient, -0.10; P = .60). Conclusion In patients suspected of having lung cancer who underwent percutaneous CT-guided coaxial lung core biopsy, there was no evidence of an association between the number of core biopsy samples obtained and any postprocedural complications. © RSNA, 2024 See also the editorial by Zuckerman in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Kim CR, Sari MA, Grimaldi E, et al. CT-guided Coaxial Lung Biopsy: Number of Cores and Association with Complications. Radiology. 2024. PMID: 39499177. doi:10.1148/radiol.232168

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。