头颈部鳞状细胞癌淋巴结评估与结外侵犯:CT与MRI的见解
回顾性纳入58例头颈部鳞状细胞癌患者,评估CT/MRI与组织学在淋巴结转移和结外侵犯中的一致性。167枚淋巴结中,影像诊断N+45枚,其中rENE+20枚;影像与病理诊断N+一致率89%(k=0.7),ENE一致率78%(k=0.5)。CT与MRI诊断N+和ENE+无统计学显著差异(p值均为0.3)。
要点
- 影像诊断淋巴结转移与病理一致率89%(k=0.7),结外侵犯一致率78%(k=0.5)。
- 脂肪门消失是判断淋巴结转移最敏感的影像征象(敏感度84%)。
- 包膜不规则伴脂肪条索是判断结外侵犯最敏感的影像征象(敏感度82%)。
核心结论
- 影像对影像学淋巴结转移(rN+)检测具有良好信心,但对影像学结外侵犯(rENE+)评估信心中等;进一步研究可能提高rENE判断的影像特异度。
研究设计与样本
- 回顾性研究,纳入在巴里综合医院接受手术及淋巴结清扫的58例头颈部鳞状细胞癌患者,评估CT/MRI与组织学在N+和ENE+中的一致性,并比较CT与MRI的诊断准确率。
诊断标准与关键数值
- 影像学N+(rN+)标准:6项特征中满足任意2项及以上;影像学结外侵犯(rENE+)标准:3项特征中满足任意1项即可。167枚淋巴结中,45/167(27%)为rN+,其中20/45(44%)为rENE+;病理检查38/45(84%)为N+,11/20(55%)为ENE+。影像与病理诊断N+一致率(149/167)89%,一致性良好(k=0.7);诊断ENE一致率(35/45)78%,一致性中等(k=0.5)。脂肪门消失判断N+敏感度84%;包膜不规则伴脂肪条索判断ENE+敏感度82%。CT与MRI诊断N+和ENE+无统计学显著差异(N+ p=0.3,ENE+ p=0.3)。
临床应用与阅片要点
- 作者认为影像对rN+检测具有良好信心,但对rENE+评估信心中等;作者指出进一步研究可能提高rENE判断的影像特异度。
局限性
- 作者指出进一步研究可能提高rENE判断的影像特异度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim of the study was to evaluate the concordance between computed tomography (CT)/magnetic resonance imaging (MRI) and histological examination in the evaluation of lymph nodal involvement (N+) and extranodal extension (ENE+) in patients with squamous cell cancer of the head-neck district (HNSCC). The second end point was to evaluate which of the imaging features was more sensitive and specific in establishing N+ and ENE+, and comparing the diagnostic accuracy between CT and MRI.
MATERIAL AND METHODS: 58 patients with HNSCC undergoing surgical treatment with lymph node dissection at the Policlinico of Bari were enrolled in this retrospective study. The criteria used for identifying radiological N+ (rN+) included six characteristics; the presence of any two or more criteria out of these six was considered rN+. For each rN+, the radiological extranodal extension (rENE+) was evaluated analyzing three characteristics; rENE was considered positive if any one criterion was present.
RESULTS: Of 167 lymph nodes, 45/167 (27%) had rN+, out of which 20/45 (44%) were rENE+. On pathological examination, 38/45 (84%) nodes were N+ and 11/20 (55%) were ENE+. The agreement between imaging and histology in the evaluation of N was (149/167) 89% with a good concordance (k = 0.7). The agreement between imaging and histology in the evaluation of ENE was (35/45) 78% with a moderate concordance (k = 0.5). Loss of fatty hilum was found to be the most sensitive (84%) imaging finding in N+ evaluation. Capsular irregularity with fat stranding had the highest sensitivity (82%) for the determination of ENE+. Comparing CT and MRI imaging in the evaluation of N+ and ENE+, we found no statistically significant differences (p-value of 0.3 for N+ and p-value of 0.3 for ENE +).
CONCLUSIONS: Imaging has good confidence in detecting rN+ but modest in assessing rENE+. Further research could improve the imaging specificity for the determination of rENE.
引用
- Maggialetti N, Villanova I, Greco S, et al. Nodal assessment and extranodal extension in head and neck squamous cell cancer: insights from computed tomography and magnetic resonance imaging. Radiol Med. 2024. PMID: 39580776. doi:10.1007/s11547-024-01929-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。