对比增强T1加权MRI检测脑转移瘤的诊断信心:3D FSE与3D GRE序列比较
本回顾性研究在3T MRI上比较了对比增强T1加权3D SPACE序列与3D FLASH序列检测脑转移瘤的表现,由5名神经放射科医师评分。SPACE在35次评估中检出更多病灶,3D FLASH在10次中检出更多;SPACE的不确定病灶更少(9 vs 27),图像质量、病灶边缘和CNR评分更优,伪影更少(P < .00001),定量CNR中位数22.9 vs 15.5但未达统计学显著(P = .134)。
要点
- SPACE序列检出更多转移灶,不确定病灶更少(9 vs 27),可提高诊断信心。
- SPACE在病灶边缘、CNR和整体图像质量Likert评分上显著优于3D FLASH,伪影更少(P < .00001)。
- 定量CNR中位数SPACE 22.9 vs 3D FLASH 15.5,未达统计学显著(P = .134)。
核心结论
- 与3D FLASH相比,SPACE序列检出更多转移灶,图像质量、病灶边缘和CNR评分更高,伪影更少,且不确定病灶更少,提高了阅片者信心。
研究设计与样本
- 单机构回顾性研究,作为实践质量改进项目的一部分,纳入72例在3T MRI上接受SPACE和3D FLASH序列的患者,由5名认证神经放射科医师评分,同一患者两序列评分间隔至少2周。
关键影像表现/征象
- 92次评估中,SPACE在35次检出更多病灶,3D FLASH在10次检出更多病灶。
- 3D FLASH上不确定病灶(n = 27)多于SPACE(n = 9)。
- SPACE在病灶边缘、CNR和整体图像质量Likert评分上显著优于3D FLASH,伪影更少(P < .00001)。
- 定量CNR中位数SPACE 22.9 vs 3D FLASH 15.5,未达统计学显著(P = .134)。
- 阅片者间病灶检出一致性Krippendorf α:SPACE 0.962,3D FLASH 0.870,两序列合并0.918。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: This retrospective study evaluated the utility of contrast-enhanced T1-weighted 3D fast spin-echo-based sampling perfection with application-optimized contrasts by using different flip angle evolutions (SPACE) sequences for brain metastasis detection on 3T MRI compared with a gradient-recalled echo-based 3D FLASH sequence.
MATERIALS AND METHODS: We identified all patients at a single institution who underwent SPACE and 3D FLASH sequences as part of a practice quality-improvement project. Their medical records were retrospectively reviewed. Five certified neuroradiologists reviewed the images, with at least 2 weeks' separation between scoring sequences for the same patient. We evaluated the following parameters: number of metastatic lesions, number of indeterminate lesions, lesion margin, contrast-to-noise ratio (CNR), extent of image artifacts, and overall image quality. The CNR was also quantified for solidly enhancing lesions of >1 cm.
RESULTS: We identified 220 patients who underwent SPACE and 3D FLASH sequences (the order of the sequences was equally distributed). Of these, 79 had brain metastases on imaging, and 7 were excluded; thus, 72 patients were included in the study. Twenty patients were scored by 2 radiologists. Of the 92 evaluations, SPACE detected more lesions than 3D FLASH in 35, while 3D FLASH detected more lesions in 10. More indeterminate lesions were seen on 3D FLASH (n = 27) than on SPACE (n = 9). For the lesion margin, CNR, and overall image quality on a Likert scale, SPACE performed significantly better than 3D FLASH, with fewer image artifacts (P < .00001). Higher quantitative CNRs were found on SPACE than on 3D FLASH images, though this result was not statistically significant (median = 22.9 versus 15.5, respectively, P = .134). There was a high interreader lesion detection concordance with the Krippendorf α ordinals at 0.962 for SPACE, 0.870 for 3D FLASH, and 0.918 for the 2 sequences combined.
CONCLUSIONS: Compared with 3D FLASH, the SPACE sequence detected more metastatic lesions and was rated higher for image quality, lesion margin, and CNR, with fewer artifacts. Importantly, the SPACE sequence resulted in increased reader confidence, with fewer indeterminate lesions detected.
引用
- Gule-Monroe M, Chasen N, Long JP, et al. Diagnostic Confidence of Contrast-Enhanced T1-Weighted MRI for the Detection of Brain Metastases: 3D FSE versus 3D GRE-Based Sequences. AJNR Am J Neuroradiol. 2025. PMID: 39572196. doi:10.3174/ajnr.A8590
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。