高壁面剪切应力与轻中度颈内动脉狭窄中复杂美国心脏协会VI型斑块相关:一项三维心血管MRI研究
本研究为前瞻性连续横断面研究,纳入121例高心血管风险患者中的39例(49条颈动脉)伴10%-50%颈内动脉狭窄者,用3T多对比高分辨MRI按改良AHA分类判断斑块成分,并用4D-flow MRI测量狭窄不同位置的壁面剪切应力(WSS)和振荡剪切指数(OSI)。结果显示复杂斑块(cCAP)在狭窄中心和狭窄后区域的WSS显著更高,WSSmean和WSSmaximum与cCAP存在独立关联,提示血流动力学可能参与其形成。
要点
- 轻中度颈内动脉狭窄中,复杂AHA VI型斑块在狭窄中心及狭窄后区域WSS显著高于稳定斑块。
- WSSmean每增加1个标准差,cCAP存在风险OR为1.97(95%CI 1.14-3.39,P=.015)。
- WSSmaximum每增加1个标准差,cCAP存在风险OR为1.84(95%CI 1.10-3.08,P=.020)。
核心结论
- 颈内动脉狭窄处较高的WSS与cCAP的存在显著相关,提示血流动力学在其形成中可能发挥作用。
研究设计与样本
- 前瞻性连续横断面研究,从121例高心血管风险患者中纳入39例(49条颈动脉)伴10%-50%颈内动脉狭窄者,采用3T高分辨多对比MRI按改良AHA分类判断斑块成分,以4D-flow MRI测量WSS和OSI。
诊断标准与关键数值
- cCAP定义为存在斑块内出血及表面缺损或血栓的复杂AHA VI型斑块,49条狭窄颈动脉中11条(22.4%)显示cCAP。
- WSSmean每增加1个标准差,cCAP存在的OR为1.97(95%CI 1.14-3.39,P=.015),校正年龄、性别和斑块厚度。
- WSSmaximum每增加1个标准差,cCAP存在的OR为1.84(95%CI 1.10-3.08,P=.020),校正年龄、性别和斑块厚度。
- WSSminimum和OSI与cCAP存在无显著关联。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Complicated American Heart Association (AHA) lesion type VI plaques and cCAPs, characterized by the presence of intraplaque hemorrhage and a surface defect or thrombus, are strongly associated with ischemic stroke and stroke recurrence. Hemodynamics seem to play a relevant role in their development. Thus, we investigated the association of 4D-flow MRI-derived local wall shear stress (WSS) and the oscillatory shear index (OSI) with the presence of cCAPs in patients with mild-to-moderate ICA stenosis.
MATERIALS AND METHODS: From a prospective and consecutive cross-sectional study with 121 patients with high cardiovascular risk, 39 patients (49 carotid arteries) demonstrated a 10%-50% ICA stenosis and were included in this analysis. Plaque composition was determined according to the modified AHA classification of lesions by high-resolution multicontrast 3T MRI. We determined WSS (minimum, mean, and maximum) and the OSI in vivo by 4D-flow MRI at different locations within the stenosis (upstream, stenosis center, and downstream). We studied the association of each hemodynamic parameter with the presence cCAPs by logistic regression analysis adjusted for age, sex and plaque thickness.
RESULTS: Eleven (22.4%) of the 49 cases of ICA stenosis in our cohort showed cCAP. WSS and OSI at the beginning of the stenosis did not differ between complicated and stable plaques. By contrast, WSS was significantly higher in the stenosis center and poststenotic region in cCAPs. OSI was significantly higher in the stenosis center of stable plaques. Logistic regression analysis revealed a significant association for WSSmean (OR per SD increase, 1.97; 95% CI, 1.14-3.39, P = .015) and for WSSmaximum (OR per SD increase, 1.84; 95% CI, 1.10-3.08, P = .020), but not for WSSminimum and OSI with the presence of cCAPs.
CONCLUSIONS: Higher WSS in ICA stenosis was significantly associated with the presence of cCAPs, underlining the potential role of hemodynamics in their development.
引用
- Strecker C, Krafft AJ, Saam T, et al. High Wall Shear Stress Is Related to Complicated American Heart Association Lesion Type VI Plaques in Mild-to-Moderate ICA Stenosis: A 3D Cardiovascular MRI Study. AJNR Am J Neuroradiol. 2025. PMID: 39547801. doi:10.3174/ajnr.A8583
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。