文献速递神经外周血管MR

nnUNet神经网络从MRI-TOF自动分割颅内动脉瘤、载瘤血管及主要脑动脉的准确性

Accuracy of an nnUNet Neural Network for the Automatic Segmentation of Intracranial Aneurysms, Their Parent Vessels, and Major Cerebral Arteries from MRI-TOF.
PubMed 文献 · AJNR Am J Neuroradiol · 2025-05-02

本研究为回顾性单中心研究,对62例MRA-TOF扫描中73个未治疗、未破裂颅内动脉瘤按21类手动标注,训练nnUNet模型实现动脉瘤、载瘤血管及主要脑动脉的全自动分割;全21类中位DSC为0.86、中位ClDice为0.91、中位HD95为2.9 mm,动脉瘤检测敏感度为0.8,动脉瘤类中位DSC为0.88、中位ClDice为0.89、中位HD95为1.8 mm,中位预测时间130.6秒;结论认为该算法可快速、充分地自动提取未破裂颅内动脉瘤及其载瘤血管和主要脑动脉。

要点

  • 全21类中位DSC为0.86、中位ClDice为0.91,分割准确性总体尚可。
  • 动脉瘤检测敏感度为0.8,动脉瘤类中位DSC为0.88、中位ClDice为0.89。
  • 标注解剖结构的体积是该模型准确性的最主要决定因素。

核心结论

  • 基于MRA-TOF的nnUNet算法可快速、充分地自动提取未破裂颅内动脉瘤、其载瘤血管及主要脑动脉。

研究设计与样本

  • 回顾性单中心研究,62例MRA-TOF扫描共73个未治疗、未破裂颅内动脉瘤,按21类手动彩色标注,训练nnUNet架构,以手动分割为参考标准,采用DSC、ClDice和HD95比较自动分割性能,并计算动脉瘤检测敏感度。

诊断标准与关键数值

  • 全21类中位DSC为0.86(95%CI 0.81-0.89),中位ClDice为0.91(95%CI 0.85-0.94),中位HD95为2.9 mm(95%CI 1.0-14.9 mm)。
  • 动脉瘤检测敏感度为0.8。
  • 动脉瘤类中位DSC为0.88(95%CI 0.13-0.92),中位ClDice为0.89(95%CI 0.06-1.0),中位HD95为1.8 mm(95%CI 0.58-81 mm)。
  • 中位预测时间为130.6秒(95%CI 60.9-284.1秒)。

临床应用与阅片要点

  • 标注解剖结构的体积是该模型准确性的最主要决定因素。
  • 未来步骤包括扩充训练集,纳入更多有或无颅内动脉瘤的MRA-TOF研究,并将其整合入3D影像浏览器和治疗预测。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The automatic recognition of intracraial aneurysms by means of machine-learning algorithms represents a new frontier for diagnostic and therapeutic goals. Yet, the current algorithms focus solely on the aneurysms and not on the recognition of their parent vessels. The purpose of the present study is the development of a new machine-learning algorithm for fully automatic identification of cerebral arteries and intracranial aneurysms (IAs) based on a manually segmented MRA-TOF data set.

MATERIALS AND METHODS: In this retrospective single-center study, 62 MRA-TOF scans of a total of 73 untreated, unruptured IAs were manually color-labeled in 21 classes. A nnUNet architecture was trained on MRA-TOF images. The performance of the automatic segmentation was compared with the manual segmentation by using the Dice Similarity Coefficient (DSC), Centerline Dice (ClDice), and 95th percentile Hausdorff Distance (HD95). Sensitivity was computed for aneurysm detection.

RESULTS: Across all 21 classes, the median DSC was 0.86 [95% CI: 0.81-0.89], the median ClDice was 0.91 [0.85, 0.94], and the median HD95 was 2.9 [1.0, 14.9] mm. Sensitivity of the model for aneurysm detection was 0.8. For this class specifically, a median DSC of 0.88 [0.13, 0.92], median ClDice of 0.89 [0.06, 1.0], and median HD95 of 1.8 [0.58, 81] mm was achieved. The volume of the labeled anatomic structure was the most relevant determinant of accuracy in this model. Median time to predict was 130.6 [60.9, 284.1] seconds.

CONCLUSIONS: The nnUNet MRA-TOF-based algorithm provided a fast and adequate automatic extraction of unruptured IAs, their parent vessels, and the most relevant cerebral arteries. Future steps involve the expansion of the training set with the inclusion of more MRA-TOF studies with and without IAs and its incorporation in 3D imaging viewers and treatment prediction.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Colombo E, de Boer M, Bartels L, et al. Accuracy of an nnUNet Neural Network for the Automatic Segmentation of Intracranial Aneurysms, Their Parent Vessels, and Major Cerebral Arteries from MRI-TOF. AJNR Am J Neuroradiol. 2025. PMID: 39578106. doi:10.3174/ajnr.A8607

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。