体素内不相干运动MRI评估小胎儿胎盘弥散与灌注特性的研究
回顾性纳入30例小胎儿与82例正常妊娠,在1.5-T MRI上行IVIM-DWI,测量脑、肺及胎盘胎儿侧与母体侧的灌注分数f、弥散系数D和伪弥散系数D*。结果显示小胎儿肺f值显著降低,FGR胎盘两侧f值低于正常,小胎儿枕叶白质和脑桥D值高于正常;IVIM-MRI可无创检测小胎儿胎盘、脑和肺的微结构与微灌注改变。
要点
- 小胎儿(SGA+FGR)肺灌注分数f显著低于正常(p=2·10-7),且f可区分SGA与FGR。
- FGR胎盘胎儿侧(p=1.4·10-7)与母体侧(p=0.001)f值均低于正常,f可区分SGA与FGR(p=0.03)。
- 小胎儿枕叶白质和脑桥D值高于正常(p=0.041;p=0.027),正常组D与孕龄负相关。
核心结论
- IVIM-MRI可无创检测小胎儿胎盘、脑和肺的微结构与微灌注改变。
研究设计与样本
- 回顾性研究,纳入30例小胎儿和82例正常妊娠,均行1.5-T MRI IVIM-DWI检查;小胎儿分为小于胎龄儿(SGA)和真性胎儿生长受限(FGR),ROI置于脑实质、肺及胎盘胎儿侧和母体侧。
关键影像表现/征象
- 肺灌注分数f在小胎儿(SGA+FGR)中显著降低(p=2·10-7)。
- FGR胎盘胎儿侧f值低于正常(p=1.4·10-7),母体侧f值亦低于正常(p=0.001)。
- 小胎儿枕叶白质和脑桥D值高于正常(p=0.041;p=0.027)。
- 幕上白质D值在正常和小胎儿中均显著高于其他脑区。
诊断标准与关键数值
- 肺f值可区分SGA与正常(p=0.001),亦可区分FGR与正常(p=1·10-6)。
- 胎盘f值可区分SGA与FGR(p=0.03)。
- 正常组肺f值随孕龄增加而升高(p<0.0001),小胎儿中亦呈正相关但显著性较低。
- 小胎儿(SGA+FGR)胎盘f值与出生体重正相关。
- 正常组脑D值与孕龄负相关,SGA+FGR组D与孕龄无相关性。
临床应用与阅片要点
- ROI需分别置于脑实质、肺及胎盘的胎儿侧和母体侧,以分别评估微灌注与微结构。
- 肺灌注分数f有助于区分SGA、FGR与正常胎儿,胎盘f值有助于区分SGA与FGR。
- 小胎儿枕叶白质和脑桥D值升高,阅片时需结合孕龄及出生体重分析。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the use of intravoxel incoherent motion (IVIM) to study microperfusion and microstructural characteristics of lungs, brain, and placenta in normal and small fetuses.
METHODS: We retrospectively enrolled 30 small fetuses and 82 normal pregnancies who underwent a 1.5-T MRI examination using an IVIM-DWI. Small fetuses were distinguished in small for gestational age (SGA) and "true" fetal growth restriction (FGR). ROIs were placed on the brain parenchyma, lungs, and fetal/maternal placental sides. Differences in perfusion fraction f, diffusion coefficient D, and pseudo-diffusion coefficient D* and their correlation with gestational age (GA) and birth weight (BW) were investigated.
RESULTS: LUNG: f showed significantly lower values (p = 2·10-7) in small fetuses (SGA + FGR); f discriminates SGA and FGR from normal (p = 0.001; p = 1·10-6). f increases with GA (p < 0.0001) in the control group; a positive correlation was also obtained in small fetuses, although less significant.
PLACENTA: FGR showed lower f values than normal ones, in both the fetal (p = 1.4·10-7) and maternal side (p = 0.001); f discriminates between SGA and FGR (p = 0.03). In small fetuses (SGA + FGR), f correlates positively with BW.
BRAIN: D values in supratentorial white matter (WM) were significantly higher compared to other regions, in both normal and small fetuses. Small fetuses showed higher D values in occipital WM and pons (p = 0.041; p = 0.027) than in normal. D correlates negatively with GA in the healthy group. No correlation between D and GA was found in SGA + FGR group.
CONCLUSIONS: In our study, IVIM-MRI allowed us to detect microstructural and microperfusion changes in the placenta, brain, and lung of small fetuses, noninvasively.
引用
- Ercolani G, Capuani S, Celli V, et al. Intravoxel incoherent motion MRI to assess feto-placental diffusion and perfusion properties in small fetuses. Radiol Med. 2024. PMID: 39541066. doi:10.1007/s11547-024-01918-4