3T 酰胺质子转移加权成像(APT-WI):肿瘤类似病变中也见信号升高
单中心回顾性分析 156 例脑占位患者,于治疗前行 3T MRI APTwi 检查,系统报告病灶及瘤周 APT-SI。肿瘤组病灶及瘤周 APT-SI 均显著高于肿瘤类似病变组;高级别胶质瘤瘤核 APT-SI 显著高于低级别胶质瘤,但肿瘤类似病变(如感染性病变)及部分低级别肿瘤亚型亦可出现高信号。
要点
- 肿瘤类似病变(如感染性病变)瘤核可出现高 APT-SI,高信号并非高级别肿瘤独有。
- 肿瘤组病灶及瘤周 APT-SI 均显著高于肿瘤类似病变组。
- 高级别胶质瘤瘤核 APT-SI 显著高于低级别胶质瘤,但低/高级别肿瘤瘤核总体比较无差异。
核心结论
- APTwi 高信号并非高级别脑肿瘤所独有,也可见于部分肿瘤类似病变和低级别肿瘤亚型。
研究设计与样本
- 单中心回顾性分析(2017-2020 年),156 例未治疗脑占位患者(男 84 例,平均年龄 50.9 ± 20 岁)行 3T MRI 检查,其中脑肿瘤 125/156(80%)、肿瘤类似病变 31/156(20%);由两名阅片者在 APTwi 图上于 2D 轴位层面手动勾画病灶及瘤周感兴趣区,系统报告 APT-SI(对应 3.5 ppm 的磁化转移率不对称性)。
关键影像表现/征象
- 肿瘤组病灶区 APT-SI 中位数 3%[Q1-Q3:2.10-4],高于肿瘤类似病变组的 1.7%[0.80-2.55](p < 0.001)。
- 肿瘤组瘤周区 APT-SI 中位数 1.9%[1.2-2.80],高于肿瘤类似病变组的 1.0%[0.55-2.3](p < 0.01)。
- 低级别与高级别肿瘤瘤核平均 APT-SI 无差异:2.5%[1.80-4.0] vs 3.25%[2.5-4.0]。
- 高级别胶质瘤平均 APT-SI 显著高于低级别胶质瘤:3.4%[2.7-4] vs 2.1%[1.7-2.5](p < 0.001)。
- 肿瘤类似病变中瘤核平均 APT-SI 最高者为感染性病变(3.52% ± 0.67,mean ± SD)。
临床应用与阅片要点
- 对脑占位行初始分类时,APTwi 所见应谨慎解读并结合其他 MRI 参数,因高 APTwi 信号不一定提示高级别肿瘤。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To explore amide proton transfer-weighted imaging (APTwi) for the initial classification of brain masses in clinical practice by systematically reporting APTwi signal intensity (APT-SI) in tumor mimics and brain tumors.
MATERIALS AND METHODS: Single-center retrospective analysis (2017-2020) of APTwi in 156 patients (84 men, mean age: 50.9 ± 20) who underwent characterization imaging of a brain mass prior to any treatment, using 3-Tesla MRI. 125/156 (80%) patients presented with brain tumor and 31/156 (20%) with tumor mimics. Regions of interest were manually drawn on 2D axial slices by two readers on APTwi map in lesional and perilesional areas and APT-SI, corresponding to the Magnetization Transfer Ratio asymmetry at 3.5 ppm, was systematically reported. Student's t-test or Wilcoxon-test were used to compare groups of patients.
RESULTS: The mean APT-SI in lesional and perilesional areas were significantly higher in tumors compared to tumor mimics: 3% [2.10-4] (median [Q1-Q3]) vs 1.7% [0.80-2.55] (p < 0.001) and 1.9% [1.2-2.80] vs. 1.0% [0.55-2.3] (p < 0.01). There were no differences in mean APT-SI in the tumor core between low and high-grade tumors: 2.5% [1.80-4.0] vs. 3.25% [2.5-4.0]. The mean APT-SI was significantly higher in high-grade glioma compared to low-grade glioma: 3.4% [2.7-4] vs. 2.1% [1.7-2.5] (p < 0.001). Highest mean APT-SI in tumor core were found in mesenchymal tumors (5.83% ± 1.45, mean ± SD), embryonal tumors (5.27% ± 3.5) and meningiomas (4.28% ± 0.70). In tumor mimics, highest mean APT-SI was found in the core of infectious lesions (3.52% ± 0.67).
CONCLUSION: High signal on ATPwi is not exclusive to high-grade brain tumors but can be observed in some tumor mimics and subtypes of low-grade tumors.
KEY POINTS: Question What is the value of amide proton transfer-weighted imaging (APTwi) in the setting of brain mass classification? Findings High APT-signal intensity in the tumor core of a brain mass could correspond to a high- or low-grade tumor or tumor mimic. Clinical relevance In patients presenting for the initial classification of brain masses, APTwi findings should be interpreted with caution and in conjunction with other MRI parameters, as a high APTwi signal does not necessarily indicate a high-grade tumor.