文献速递神经外周血管CT

双能CT鉴别缺血性卒中血栓类型

Discrimination of thrombus types in ischemic stroke using Dual-Energy CT.
PubMed 文献 · Eur J Radiol · 2024-11-10

纳入42例急性缺血性卒中取栓前接受脑双能CT平扫及CT灌注的患者,术后病理分析血栓成分,其中红细胞为主型24例、纤维蛋白/血小板为主型18例。双能CT多色图像CT值鉴别两型的AUC为0.924(0.848-0.999),阈值59 HU,敏感度79.2%、特异度94.4%;联合诊断AUC达0.938(0.863-1.012)。

要点

  • 红细胞为主型血栓的双能CT多色图像CT值、有效原子序数和光谱曲线斜率均显著高于纤维蛋白/血小板为主型。
  • 多色图像CT值鉴别两型的AUC为0.924(0.848-0.999),阈值59 HU,敏感度79.2%、特异度94.4%。
  • 双能CT参数与红细胞比例显著相关(r=0.673、0.574、0.571,均p<0.01)。

核心结论

  • 双能CT平扫参数与血栓成分相关,可能有效鉴别红细胞为主型与纤维蛋白/血小板为主型血栓。

研究设计与样本

  • 纳入42例急性缺血性卒中患者,取栓前接受脑双能CT平扫及脑CT灌注,术后病理分析血栓成分;双能CT重建多色图像和有效原子序数图像。

关键影像表现/征象

  • 红细胞为主型血栓的有效原子序数、光谱曲线斜率和多色图像CT值均显著高于纤维蛋白/血小板为主型。
  • 纤维蛋白/血小板为主型血栓的平均血栓衰减增加值较大,但差异无统计学意义。

诊断标准与关键数值

  • 多色图像CT值鉴别红细胞为主型与纤维蛋白/血小板为主型血栓的AUC为0.924(0.848-0.999),阈值59 HU,敏感度79.2%,特异度94.4%。
  • 联合诊断AUC为0.938(0.863-1.012),敏感度87.5%,特异度94.4%。
  • 双能CT多色图像CT值、有效原子序数和光谱曲线斜率与红细胞比例显著相关(r=0.673、0.574、0.571,均p<0.01)。

临床应用与阅片要点

  • 取栓前双能CT平扫可测量血栓多色图像CT值、有效原子序数和光谱曲线斜率,用于提示血栓以红细胞为主还是以纤维蛋白/血小板为主。
  • 多色图像CT值59 HU可作为鉴别两型血栓的参考阈值,联合有效原子序数和光谱曲线斜率可提高诊断AUC至0.938。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study explores the clinical utility of dual-energy computed tomography (DECT) in discriminating thrombus types in ischemic stroke.

METHODS: Patients with acute ischemic stroke who underwent brain DECT non-contrast scanning and brain CT perfusion (CTP) before thrombectomy were included, and the thrombus composition was analyzed by postoperative pathology. DECT data was conducted to reconstruct polychromatic images and effective atomic number images. Computed tomography (CT) values, effective atomic numbers, and spectral curve slopes of the thrombus were measured and calculated. Thrombus attenuation increase was obtained from CTP data. Parameters were compared between red blood cell (RBC)-dominant thrombi and fibrin/platelet (F/P)-dominant thrombi. Thresholds, sensitivity, specificity, and area under the curve (AUC) were analyzed to distinguish these thrombi. The associations between DECT parameters and proportion of RBCs were analyzed by Spearman's correlation.

RESULTS: Pathological analysis of 42 enrolled patients revealed 24 cases of RBC-dominant thrombi and 18 cases of F/P-dominant thrombi. Effective atomic numbers, spectral curve slopes, and polychromatic images CT values were significantly higher in the RBC-dominant thrombi group compared with the F/P-dominant thrombi group. Although the average thrombus attenuation increase was greater in the F/P-dominant thrombi group, this difference was not statistically significant. Among the DECT parameters, polychromatic images CT values had the greatest AUC at 0.924 (0.848-0.999) for discriminating RBC-dominant and F/P-dominant thrombi, with a threshold of 59 HU, sensitivity of 79.2 %, and specificity of 94.4 %. The combined diagnostic AUC reached 0.938 (0.863-1.012), with 87.5 % sensitivity and 94.4 % specificity. DECT polychromatic images CT values, effective atomic numbers, and spectral curve slopes were significantly correlated with proportion of RBCs (r = 0.673, 0.574, and 0.571, all p < 0.01).

CONCLUSION: DECT non-contrast scan parameters are associated with thrombus composition, which could be effective in distinguishing between RBC-dominant and F/P-dominant thrombi.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Hou G, Chen H, Luo L, et al. Discrimination of thrombus types in ischemic stroke using Dual-Energy CT. Eur J Radiol. 2024. PMID: 39541613. doi:10.1016/j.ejrad.2024.111832

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。