文献速递神经外周血管CTDSA

动态CT血管成像评估在体脑动脉搏动

In-vivo cerebral artery pulsation assessment with Dynamic computed tomography angiography.
PubMed 文献 · Eur J Radiol · 2024-11-13

这项观察性研究在Radboud大学医学中心纳入18例未破裂未治疗颅内动脉瘤成人患者,用ECG门控4D CTA连续捕捉三个心动周期的脑动脉管腔直径,以评估血管运动。结果未能配准到任何搏动,可能因搏动运动低于检测阈值并叠加信噪比不足所致。

要点

  • 4D CTA在18例患者三个心动周期中未配准到脑动脉搏动。
  • 作者认为未检出搏动可能与运动低于检测阈值及信噪比不足有关。
  • 需进一步研究大颅内结构和新型高空间分辨率扫描仪的可重复性。

核心结论

  • 4D CTA似为捕捉脑动脉血管运动的有前景技术,但本研究中未能配准到搏动。

研究设计与样本

  • 观察性研究,在Radboud大学医学中心纳入18例未破裂且未治疗的颅内动脉瘤成人患者。
  • 使用宽探测器CT系统行ECG门控4D CTA,捕捉三个心动周期。
  • 采用刚体配准减少采集期间小头动影响,选取三段10 mm脑动脉节段,用可变形配准算法计算管腔总形变作为血管运动的替代测量。

关键影像表现/征象

  • 三个心动周期中未能配准到任何搏动。

局限性

  • 未能配准到搏动,可能因搏动运动低于检测阈值并叠加信噪比不足。
  • 需进一步研究能否评估较大颅内结构。
  • 需进一步研究使用新型高空间分辨率扫描仪能否对此尺寸动脉获得可重复测量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Four-Dimensional Computed Tomography Angiography (4D CTA) seems a promising technique for capturing vessel motion of cerebral arteries, which may help to assess pathological conditions such as intracranial aneurysms. The goal of our current observational study is to capture the lumen diameter of cerebral arteries during three subsequent cardiac cycles with 4D CTA and to assess vessel motion, anticipating consistent expansion patterns within each cardiac cycle. Eighteen adult patients with unruptured and untreated intracranial aneurysms were recruited at Radboud University Medical Center. Three cardiac cycles were captured, on a wide detector CT system, using ECG-gated 4D CTA. To reduce the impact of small head movements during the acquisition, a rigid-body registration was employed. Three 10 mm segments of cerebral arteries were selected. The total deformation of the vessel lumen was calculated using a deformable registration algorithm and was used as a substitute measure for vessel motion. No pulsations could be registered, which was probably caused by pulsation motion below threshold of detection in combination with insufficient Signal-to-Noise Ratio. Further studies need to investigate if large intracranial structures can be evaluated and if using a novel scanner with a high spatial resolution would result in reproducible measurements of arteries this size.

来源:Eur J Radiol,查看原文。版权归原作者所有。